UNI-T UT81B Oscilloscope Multimeter

حالة: Discontinued Old monochrome, single-channel oscilloscope multimeter (oscilloscope + multimeter 2-in-1). Do not confuse it with the new colour dual-channel UT81B+. Oscilloscope Specifications Bandwidth: 8 MHz Real-time sampling rate: 40 MSa/s Vertical sensitivity: 20 mV/div ~ 500 V/div (1-2-5 sequence) Vertical accuracy: ±(5%+1) Timebase accuracy: ±(0.01%+1) سمات: Auto setup, waveform storage, USB waveform upload to ...

  • تفاصيل المنتج

حالة: توقف

Old monochrome, single-channel oscilloscope المتر المتعدد (oscilloscope + multimeter 2-in-1). Do not confuse it with the new colour dual-channel UT81B+.

  1. Oscilloscope Specifications

Bandwidth: 8 ميغاهيرتز

Real-time sampling rate: 40 MSa/s

Vertical sensitivity: 20 mV/div ~ 500 V/div (1-2-5 sequence)

Vertical accuracy: ±(5%+1)

Timebase accuracy: ±(0.01%+1)

سمات: Auto setup, waveform storage, USB waveform upload to PC, trigger adjustment

  1. DMM Multimeter Specifications (3999 counts)

الأمراض القلبية الوعائية: 400 mV ~ 1000 V, accuracy ±(0.8%+8)

خل التفاح: 4 V ~ 750 V, accuracy ±(1%+15)

DCA: 400 μA ~ 10 أ, accuracy ±(1%+8)

ACA: 400 μA ~ 10 أ, accuracy ±(1.5%+8)

مقاومة: 400 Ω ~ 40 مΩ, ±(1%+5)

السعة: 40 nF ~ 100 ميكروف, ±(3%+8)

Extra functions: Diode test, صفارة الاستمرارية, تكرار, دورة العمل (0.1%~99.9%)

  1. مقارنة النماذج (Critical to avoid mistakes)
نموذجOscilloscope ChannelsBandwidthعرضحالة
UT81BSingle channel8 ميغاهيرتزشاشات الكريستال السائل أحادية اللونتوقف
UT81CSingle channel16 ميغاهيرتزشاشات الكريستال السائل أحادية اللونتوقف
UT81B+Dual channel100 ميغاهيرتزلونActive new model, with signal generator
  1. التطبيقات & القيود

✅ Suitable for: Simple waveform inspection in industrial control, power supply ripple, تتابع / low-frequency inverter signals, إصلاح الأجهزة, portable on-site commissioning

❌ القيود: Single channel, low bandwidth, monochrome screen, no built-in signal generator, توقف. For high-frequency or dual-channel requirements, choose UT81+ series.

  1. واجهات & مُكَمِّلات

محطات الإدخال: 10أ, mA/μA, كوم, SCOPE (BNC for oscilloscope)

تواصل: USB, bundled PC software for waveform export

مزود الطاقة: Battery-powered handheld unit

  1. مرجع الاختيار البديل

If you need a replacement for the UT81B:

Similar handheld oscilloscope multimeter: UT82B (50 ميغاهيرتز, single channel)

Dual channel + signal generator: UT81C+ / UT81D+

UNI-T UT81B (Old Monochrome Model) Practical Tutorial Collection

Important reminder: Most online videos cover the UT81B+ (new colour dual-channel version). Its buttons and menus are different from this discontinued old UT81B. All content below applies to the old single-channel UT81B, for industrial repair, العاكسون, power ripple and relay signal debugging.

  1. Document Tutorials (Authoritative, priority reading)
  2. Original factory English manual (UT81A/B)

Covers button definitions, menus, النطاقات, triggering, cursors, USB communication, battery and fuse replacement. It is the only official document for this meter. Search PDF with keyword: `UT81A/B OPERATING MANUAL`

It fully describes: MODE toggle between multimeter DMM and oscilloscope SCOPE, AUTO setup, AUTO/NORM/SHOT trigger modes, waveform storage (الأعلى 10 مجموعات), backlight and contrast settings.

  1. Third-party notes (industrial community)

Search keyword: `UT81B handheld oscilloscope multimeter repair notes`. Many appliance and inverter repair technicians share practical cases: measuring switching power supply ripple, PWM drive waveforms, relay pull-in chatter.

  1. Step-by-step Practical Tutorials

✅ Tutorial 1: Basic switching + probe compensation (mandatory first step)

  1. الأسلاك: Connect BNC oscilloscope probe to the SCOPE port. Attach the black clip to circuit ground, hook the probe tip to the test point. Set the probe to ×1 or ×10, and match the attenuation setting in the menu.
  2. تشغيل الطاقة. Press MODE to switch between [DMM Multimeter Mode] ↔ [SCOPE Oscilloscope Mode].
  3. Enter oscilloscope mode, press AUTO: auto-adjust vertical range, timebase and trigger. Always use AUTO for unknown signals.
  4. Probe compensation: The old UT81B has no built-in calibration square wave! You need a signal source or known standard square wave to calibrate the probe, otherwise waveform edges will be distorted.

✅ Tutorial 2: Core Oscilloscope Menus (UT81B monochrome menu)

RANGE menu: F1 move waveform up / F2 move waveform down / F3 increase V/div / F4 decrease V/div

BASE menu: F1 move waveform left / F2 move waveform right / F3 increase timebase s/div / F4 decrease timebase

TRIG trigger menu: AUTO (baseline runs without valid signal), NORM (waveform only appears when trigger condition is met), SHOT single capture (for pulses and transient spikes, very useful for industrial work); F1/F2 adjust trigger level, ارتفاع / falling edge

MEAS cursor measurement: Enable cursors to manually read peak-to-peak value and period. The old UT81B has no automatic measurement readout, all values must be calculated manually with cursors — this is the biggest difference from UT81B+.

SAVE: Store waveforms, ما يصل الى 10 screens for later recall

SYSTEM: الإضاءة الخلفية, beeper, auto power-off, contrast

✅ Tutorial 3: USB PC waveform upload tutorial (common pain point)

  1. Matching legacy software: UT81 series PC software (not compatible with new UT81+ software)
  2. Connect USB cable between PC and UT81B, switch the meter to oscilloscope mode
  3. Select the corresponding COM port in software, read waveforms, save screenshots and export data

شرك: Win10 / Win11 often lacks the old USB-to-serial driver, CH340 driver is required; compatibility is poor on Win11.

✅ Tutorial 4: High-frequency industrial application scenarios

  1. Switching power supply ripple measurement

اقتران: AC coupling (remove DC offset), timebase 20 μs ~ 100 ميكروس, vertical setting 20 mV/div. Keep the ground clip lead as short as possible to reduce interference. Bandwidth limit 8 ميغاهيرتز, high-frequency ripple cannot be measured accurately.

  1. Inverter PWM and relay pull-in waveform

Use SHOT single-shot trigger to capture transient spikes at power-on; select rising edge triggering. Pay attention to common ground to avoid damaging the meter.

  1. Switch between multimeter and oscilloscope

Press MODE back to DMM to measure voltage, resistance or capacitance without changing instruments, convenient for on-site troubleshooting.

✅ Tutorial 5: Common troubleshooting

Waveform drifting, hard to trigger: Switch to NORM trigger, adjust trigger level manually, verify solid ground connection

Waveform amplitude too small: Check that probe attenuation matches menu setting (×10 probe without menu setting will give 10× reading error)

AUTO function fails: AUTO does not work when timebase >50 آنسة, parameters must be adjusted manually

Dim screen: Adjust contrast in SYSTEM menu

  1. Video Search Tips (Avoid mixing models)

Search on Bilibili / Douyin with these keywords to distinguish old and new versions:

  1. المفضل: `Old UT81B monochrome oscilloscope multimeter demo`
  2. بديل: `UT81C handheld oscilloscope tutorial` (UT81C shares nearly identical menu logic with UT81B, فقط 16 MHz bandwidth, suitable for reference)

❌ Do NOT search: `UT81B+`, interface and buttons are completely different and will confuse you.

General oscilloscope theory videos are applicable; vertical scale, timebase and trigger principles are universal.

  1. Learning Roadmap
  2. Read the original manual first and get familiar with buttons and menus (the monochrome UI has limited text and is confusing for new users)
  3. Practice with 50 Hz mains waveform to master AUTO, triggering and cursors
  4. Learn SHOT single capture (most valuable for industrial troubleshooting)
  5. Finally practise USB waveform upload to PC