Univer AG-3232 Vacuum Poppet Valve - المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية

ويشات: +86-13184948252 واتس اب: 0086-13811255435 بريد إلكتروني: كينت@bestcontactor.com

عن اتصال |

Univer AG-3232 Vacuum Poppet Valve - المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية

كهربائي/

Univer AG-3232 Vacuum Poppet Valve

The AG-3232 is a 3/2-way normally closed vacuum poppet valve. It adopts electric solenoid control with vacuum pilot operation and features G3/4port size. It is ideal for vacuum systems requiring high flow rate and high cycle frequency. Model Code Explanation Breakdown of the AG-3232 model code: Code Meaning Detailed Description AG Series Code AG ...

  • تفاصيل المنتج

The AG-3232 is a 3/2-way normally closed vacuum poppet valve. It adopts electric solenoid control with vacuum pilot operation and features G3/4port size. It is ideal for vacuum systems requiring high flow rate and high cycle frequency.

  1. شرح كود النموذج

Breakdown of the AG-3232 model code:

شفرةمعنىوصف تفصيلي
AGكود السلسلةAG Series Vacuum Poppet Valve. Featuring Univer patented poppet structure, مصممة خصيصًا لتطبيقات الفراغ.
3Circuit Type3-way, 2-position valve
2Control ModeElectric solenoid with vacuum pilot
3Normal Positionمغلق عادة (نورث كارولاينا)
2حجم المنفذG3/4″ (DN20) threaded port
  1. Main Technical Specifications
فئةمواصفةملاحظات
Basic Characteristics
Valve TypePoppet ValveExcellent sealing performance for vacuum service
Control ModeElectric solenoid with vacuum pilotExternal vacuum pilot supply (G1/4″ ميناء)
Normal Positionمغلق عادة (نورث كارولاينا)Vacuum port closes when power off or no pilot supply
Circuit Configuration3/2-way1 vacuum port, 1 exhaust port, 1 working port
Port Dimensions
Main Port SizeG3/4″ (DN20)Working port / Vacuum port
Pilot Port SizeG1/4External vacuum pilot supply
معلمات الأداء
Maximum Vacuum759.5 mmHg (0.5 Torr)تقريبا. -0.1 MPa absolute pressure
Minimum Vacuum150 mmHg (610 Torr)Applicable vacuum range
درجة الحرارة المحيطةالأعلى. +50掳CKeep away from high-temperature environments
Working MediumFiltered air (50渭m), lubricated or non-lubricatedClean and dry air is mandatory
Solenoid Voltage12في العاصمة, 24في العاصمة, 24الخامس و, 110الخامس و, 230الخامس وMultiple coil options available
Manual Operation2-position screw manual overrideManual state switching available during power failure
المعلمات المادية
وزنتقريبا. 1.13-1.17 كجمSlight variations among suppliers
مادةValve body: سبائك الألومنيوم; Seals: Nitrile Butadiene Rubber (نبر)التكوين القياسي; Viton seals optional
  1. Cross-brand Comparison & البدائل المحلية
ماركةنموذجFunction Matching Rateالسعر المرجعي (يورو)المزايا
UniverAG-3232100%148-228Original genuine product with patented poppet structure and optimal sealing performance
FESTOVUVS-L30-M32C-MD-G18-F795%280-350Well-known brand with comprehensive supporting services
SMCVV5Q3-30-0690%220-280Fast response and compact structure
AVENTICS581140022090%200-250Good contamination resistance, مناسبة لظروف العمل القاسية
البديل المحلي (E.MC)VT307-03NC85%80-120Cost-effective and short delivery lead time
البديل المحلي (القطب الشمالي)3V3-08-NC80%60-90Competitive price, ideal for budget-limited projects

توصيات الاختيار

  1. For precision equipment requiring stable vacuum performance, prioritize the original Univer AG-3232.
  2. For general industrial applications, FESTO or SMC alternatives are recommended for similar performance and extensive service networks.
  3. For cost-sensitive projects, choose domestic alternatives from E.MC or AIRTAC for higher cost performance.
  4. Full Model List of AG Series

The AG series vacuum poppet valves cover port sizes from G1/8to G1 1/2″. Common models are listed below:

نموذجحجم المنفذControl ModeNormal Positionملاحظات
AG-3001G1/8Solenoid with vacuum pilotنورث كارولايناMini size for low flow applications
AG-3002G1/8Solenoid with vacuum pilotلاNormally open type for continuous vacuum operation
AG-3003G1/4Solenoid with vacuum pilotنورث كارولايناGeneral size for small & medium vacuum cup systems
AG-3004G1/4Solenoid with vacuum pilotلاNormally open, G1/4″ ميناء
AG-3041G3/4Solenoid with vacuum pilotلاHigh flow normally open type, NO version of AG-3232
AG-3081G1/2Solenoid with vacuum pilotنورث كارولايناMedium flow, G1/2″ ميناء
AG-3222G1/2Solenoid with vacuum pilotلاMedium flow normally open type
AG-3232G3/4Solenoid with vacuum pilotنورث كارولايناSubject model, high flow normally open type
AG-3303G1Solenoid with vacuum pilotنورث كارولايناExtra high flow for large-scale vacuum systems
AG-3322G1Solenoid with vacuum pilotلاExtra high flow normally open type
AG-3403G1 1/2Solenoid with vacuum pilotنورث كارولايناMax size for heavy industrial vacuum applications
  1. الأخطاء الشائعة & استكشاف الأخطاء وإصلاحها
ظاهرة الخللالأسباب المحتملةInspection Stepsالحلول
Insufficient vacuum1. Aged/damaged seals1. Check seals for cracks or wear1. Replace seals (recommended every 12 شهور)
2. Insufficient pilot pressure2. Measure pilot vacuum (≥150 mmHg required)2. Increase pilot vacuum supply
3. Internal valve leakage3. Conduct valve pressure test3. Repair or replace the valve
Valve fails to operate1. Faulty solenoid coil1. Check coil voltage & مقاومة (15-25Ω for standard 24V DC coil)1. Replace solenoid coil
2. Manual override not reset2. Confirm manual screw is reset2. Screw back the manual override
3. Blocked pilot pipeline3. Dismantle pipeline and check for foreign matters3. Clean pipeline and install filter
Slow valve operation1. Contaminated working medium1. Check clogged filter1. Replace filter and clean the system
2. Delayed solenoid response2. Test solenoid response time (<50ms required)2. Replace solenoid coil
3. Overloaded vacuum system3. Inspect vacuum system for leakage3. Fix leakage points of vacuum system
Frequent failures1. ارتفاع درجة الحرارة المحيطة بشكل مفرط1. Measure ambient temperature (≤+50°C required)1. Add cooling devices or adopt high-temperature resistant model
2. Excessive oil/water in medium2. Check air treatment unit2. Upgrade air treatment system (add dryer)
3. Incorrect installation direction3. Verify installation against flow arrow3. Reinstall the valve correctly

Maintenance Schedule

يوميًا: Check vacuum level and valve operation regularly.

ربع سنوية: Clean filters and inspect seal condition every 3 شهور.

سنويا: Replace seals and carry out full inspection & maintenance for the valve.

  1. حالات التطبيق & Industry Guidelines

6.1 سيناريوهات التطبيق النموذجية

خطوط الإنتاج الآلي: Vacuum material handling systems for metal sheets, glass, plastic parts, إلخ.

ماكينات التعبئة والتغليف: Vacuum thermoforming machines for food, pharmaceutical and other products.

Semiconductor Equipment: Wafer handling systems requiring high vacuum and high cleanliness.

Woodworking Machinery: Vacuum workholding tables for wood cutting, engraving and processing.

Printing Machinery: Paper conveying systems using vacuum adsorption for stable paper feeding.

6.2 حالات تطبيق الصناعة

قضية 1: Automotive Component Production Line

طلب: Engine block handling

Working Condition: Handling cast iron blocks up to 50 كجم; Vacuum requirement ≥ -0.08 MPa

حل: AG-3232 equipped with 4 pcs of Φ200 mm vacuum cups, matched with vacuum generator

حصيلة: Stable handling without falling risks; زادت كفاءة الإنتاج بنسبة 30%.

قضية 2: Display Panel Assembly Line

طلب: LCD panel handling

Working Condition: High cleanliness required; Vacuum requirement ≥ -0.09 MPa; prevent panel scratches

حل: AG-3232 + soft silicone vacuum cups, matched with oil-free vacuum pump

حصيلة: Scratch-free handling with 100% yield rate, compliant with cleanroom standards.

6.3 إرشادات الاختيار

Port Selection: Choose port size from G1/8to G1 1/2according to required vacuum flow.

Normal Position Selection: NC for intermittent operation; NO for continuous operation.

Control Mode Selection: Solenoid with vacuum pilot for high flow; direct solenoid for low flow.

Vacuum Matching: Ensure system vacuum stays within 150 ~ 759.5 mmHg.

الصيانة الدورية: Replace seals periodically and keep air source clean.

  1. تثبيت & Operation Precautions
  2. Installation Direction: Install the valve strictly in line with the flow direction arrow marked on the body.
  3. Pilot Supply: Maintain stable pilot vacuum pressure; pressure regulator is recommended.
  4. Filtration: Install a 50μm filter at the air inlet to prevent foreign matters from entering the valve.
  5. Electrical Wiring: Wire in accordance with the rated coil voltage to avoid overload or short circuit.
  6. بيئة التشغيل: Do not use in environments with temperature over +50°C, high humidity or corrosive gas.
  7. Manual Override: Only use manual operation in emergency situations; reset it after use.