Carlo Gavazzi WM12-96.AV5.3.3.S - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

Carlo Gavazzi WM12-96.AV5.3.3.S - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

NachrichtHandelsnachrichten

Carlo Gavazzi WM12-96.AV5.3.3.S

Carlo Gavazzi WM12-96.AV5.3.3.S

ModellsegmentBedeutungDetaillierte Beschreibung
WM12-96Basismodell96×96mm panel-mounted three-phase multifunction power indicator with built-in programming keypad
AV5Range Code380/660V L-L / 5(6)Und AC; VL-N: 185V ~ 460V; VL-L: 320V ~ 800V
3Systemtyp1/2/3-phase system, unbalanced load, with or without neutral line
3Power Supply Type18 to 60VDC power supply, fluctuation range: -15% Zu +10%
SFunction OptionWith RS485 serial output (X = without this function)
  1. Kernspezifikationsparameter

2.1 Measurement Performance

ParameterWertBemerkungen
GenauigkeitsklasseCurrent/Voltage: ±0.5% FSAt 25°C±5°C, RH≤60%
Leistung: ±(1% FS + 1 Digit)
Frequenz: ±0.1%Hz
Measurement MethodTrue RMS (TRMS)Supports distorted sine wave measurement
Sampling Rate1700 samples/s @ 60Hz
Display Refresh Rate700MS
Measured VariablesSystem & phase values: W, Wdmd, var, VA, VAdmd, PF, V, A, An, Hz3×3-digit LED display, 14mm digit height
Max value indication: Amax, Wdmd max

2.2 Elektrische Spezifikationen

ParameterWertBemerkungen
Rated InputAktuell: 5(6)ACurrent input must be connected via CT; direct connection prohibited
Stromspannung: See model definition for AV5 range
Auxiliary Power18 ~ 60VDC, Stromverbrauch: 4W
ÜberlastschutzKontinuierlich: 1.2×FS
500ms surge: Voltage 2×Un, Current 36A
Spannungsfestigkeit4000VAC / 1min (Between measurement input and power/RS485)Konform mit IEC 60664

2.3 Körperlich & Environmental Specifications

ParameterWertBemerkungen
Panel-Abmessung96×96mmStandard panel mounting size
Schutz vor EindringenFront: IP65 (NEMA4x/12); Terminals: IP20
Betriebstemperatur-10°C ~ +50°CRH<90%, nicht kondensierend
Lagertemperatur-30°C ~ +60°CRH<90%, nicht kondensierend
InstallationskategorieCategory IIIKonform mit IEC 60664
GewichtCa. 400G (with packaging)

2.4 Communication Specifications (S Option)

ParameterWertBemerkungen
SchnittstellentypRS422/RS485Multi-point bidirectional communication
Communication DistanceMax. 1200M2-wire or 4-wire connection
Adressbereich1 ~ 255Keypad configurable
Data Format1 start bit, 8 Datenbits, keine Parität, 1 Stoppbit
Baudrate9600 bit/s
  1. Standard Accessories List
  2. WM12-96.AV5.3.3.S Main Unit (with built-in programming keypad)
  3. Mounting Fasteners (Clips / Screws)
  4. Multilingual Instruction Manual
  5. Terminal Identification Labels
  6. RS485 Communication Terminal Block (if S option is selected)
  7. Product Certification Documents (CE, cULus)
  8. Wettbewerber & Cross-Brand Replacement Comparison
MarkeModellMain DifferencesAnwendungsszenarien
Carlo GavazziWM12-96.AV5.3.3.SBuilt-in keypad, 96脳96 panel, RS485, IP65Industrielle Automatisierung, Building Energy Management
Schneider ElectricPM2000Graphic LCD, Modbus RTU/TCP, more measurement parametersHigh-end Energy Management System
Siemens7KM2112Integrated energy metering, Profibus DP, höhere GenauigkeitProcess Industry, Smart Grid
ABBE200Kompaktes Design, mehrere Kommunikationsprotokolle, kostengünstigGebäudeautomation, OEM Equipment
Carlo GavazziWM3-9632-bit 渭P, graphic display, advanced analytical functionsPower Quality Monitoring
  1. Auswahlrichtlinien & Ersatzlösungen

Selection Mnemonic

AV5 for high voltage / AV6 for low voltage; 3 for 3-phase system / 3 for DC power; S with communication / X without

Selection Decision Tree

  1. Spannungspegel: Select AV5 for above 380V; select AV6 for below 208V
  2. Systemtyp: 3 = Three-phase (Empfohlen); others = Single-phase / Two-phase / ARON system
  3. Stromversorgung: 3 = 18-60VDC; A=24VAC; B=48VAC; C=115VAC; D=230VAC
  4. Kommunikation: S = Mit RS485; X = Without communication
  5. Montageart: WM12-96 = Panel Mount; WM12-DIN = DIN Rail Mount

Empfohlene Ersatzlösungen

Requirement ChangeEmpfohlenes ModellGrund
DIN-SchienenmontageWM12-DIN.AV5.3.3.SSaves panel space, suitable for control cabinet installation
Lower Voltage SystemWM12-96.AV6.3.3.SCompatible with 120/208V systems
No Communication NeededWM12-96.AV5.3.XCost reduction with unchanged basic display functions
Higher Functional DemandWM3-9632-bit processor, graphic display, power quality analysis
  1. Anwendungsszenarien & Customer Value
  2. Industrielle Automatisierung: Real-time monitoring of electrical parameters for motors, inverters and other equipment to prevent overload and faults.
  3. Building Energy Management: Monitor three-phase power distribution systems, optimize energy consumption and reduce operational costs.
  4. OEM Equipment Integration: Embedded as standard configuration in machine tools, Verpackungsmaschinen, usw., for equipment status monitoring.
  5. Data Center: Monitor UPS output and distribution cabinet load to ensure stable power supply.
  6. Erneuerbare Energie: Measure output parameters of photovoltaic inverters and wind turbines for energy efficiency evaluation.

Core Value: With high-precision TRMS measurement and multi-parameter display, it helps users quickly identify electrical abnormalities, optimize energy consumption, extend equipment service life and reduce maintenance costs.

Carlo Gavazzi WM12-96.AV5.3.3.S End-of-Life Information

Wichtigste Schlussfolgerung: This model together with the entire WM12 series was officially discontinued in April 2020. The official replacement is the WM15 series, while the WM14 series can be used as a temporary transitional replacement.

  1. Official EOL Basis

Carlo Gavazzi officially released an announcement in April 2020:

With the launch of the new WM15, the WM12, WM14, and EM26 are discontinued.

As a 96×96mm panel-mounted three-phase multifunction power indicator in the WM12 series, WM12-96.AV5.3.3.S is included in this full-series discontinuation.

  1. EOL Timeline & Replacement Arrangement
Time NodeEventBemerkungen
Apr-20WM15 series launched; WM12 series officially discontinuedOfficial EOL (End of Life) Datum
Before DiscontinuationWM14 series as upgraded replacement for WM12WM14-96AV533S is direct drop-in replacement for WM12-96.AV5.3.3.S
After April 2020WM15 series becomes final successor to WM12/WM14Higher accuracy (Klasse 1 kWh) and added functions such as harmonic analysis
  1. Key Information of Replacement Products
  2. Direct Drop-in Replacement:

WM14-96AV533S (WM14-96×96 400/660V 5AAC 18-60VDC SERIAL)

Identical 96×96mm panel size and mounting method

Same AV5 range: 380/660V L-L / 5(6)Und AC

Same 18-60VDC power supply and RS485 communication

  1. Final Upgraded Replacement: WM15-Serie

Accuracy upgraded to Class 1 für aktive Energie

Added harmonic distortion measurement

Supports single/two/three-phase and wild-leg systems

Optional pulse output, Modbus RTU or M-Bus communication

  1. Einkauf & Wartungsempfehlungen
  2. Stock Status: Only limited second-hand or surplus stock available; brand new original units are nearly out of stock.
  3. Maintenance Support: Carlo Gavazzi generally provides 6 years of spare parts support for discontinued models.
  4. Model Migration: New projects are recommended to adopt the WM15 series directly; existing projects can use the WM14 series for transitional upgrading.

Replacement Analysis of WM12-96.AV5.3.3.S and WM12-96.AV5.3.3.X

Core Conclusion: The two models are physically and hardware compatible and can be directly interchanged for installation; Jedoch, there is a key difference in communication functions. Their interchangeability depends on whether the system requires RS485 communication.

  1. Core Difference Comparison (Only One Distinction)
ModellHauptunterschiedFunktionelle AuswirkungenApplication Limitation
WM12-96.AV5.3.3.SWith RS485 serial communication (S=Serial)Supports communication with host computer/PLC via Modbus RTU protocol for remote monitoring and data acquisitionSuitable for automation systems requiring centralized monitoring
WM12-96.AV5.3.3.XWithout RS485 communication (X=No Serial)Only local LED display available; remote data reading not supportedSuitable for simple applications requiring only on-site parameter viewing

All other parameters are completely identical:

Basismodell: WM12-96 (96×96mm panel mounting, with built-in programming keypad)

Range code: AV5 (380/660V L-L / 5(6)Und AC)

System type: 3 (1/2/3-phase system, unbalanced load)

Power supply type: 3 (18-60VDC power supply)

Identical measurement accuracy, electrical specifications, physical dimensions and ingress protection rating

  1. Interchangeability Feasibility Judgment

2.1 ✅ Applicable Interchange Scenarios (Bidirectional)

System does not require RS485 communication: The X model can directly replace the S model, saving cost while fully meeting on-site display requirements.

Temporary replacement only: Either model can be used as a temporary spare part for fault maintenance without affecting basic measurement and display functions.

Neues Projektdesign: Selection based on actual communication demand; hardware mounting dimensions and wiring are fully compatible.

2.2 ❌ Non-interchangeable Scenarios (Unidirectional Restriction)

OriginalmodellTarget ModelReason for Non-interchangeabilityLösung
S (With Communication)X (Without Communication)The system relies on RS485 remote monitoring; communication will be interrupted after replacementKeep S model, or upgrade to communication-enabled WM15 series
X (Without Communication)S (With Communication)No communication wiring or host interface in the system; the communication function cannot be usedNo need for replacement, or upgrade after completing communication infrastructure
  1. Key Points for Replacement Operation

3.1 Physische Installation

Exactly the same 96×96mm panel cutout size, direct plug-and-play replacement.

Consistent terminal definition; no modification required for main circuit and power wiring.

Same ingress protection level (Vorne IP65, Terminal IP20) with consistent environmental adaptability.

3.2 Function Configuration

The built-in programming keypad operates identically; original parameter settings can be copied directly.

Fully compatible in measurement parameters, display modes and alarm threshold configuration.

When replacing X with S, additional configuration of RS485 address (1-255) and communication parameters (9600bps, 8N1) ist erforderlich.

3.3 Einstellung & Ersatzempfehlung

Both models were officially discontinued in April 2020 together with the entire WM12 series.

Official final replacement: WM15-Serie (Klasse 1 höhere Genauigkeit, with additional harmonic analysis function).

Transitional replacement: WM14-96AV533S / WM14-96AV533X (retains the same panel size and functions).

  1. Auswahl & Decision Summary

Communication demand is the key; S with comm, X without. Physically interchangeable, only reliable with function matching.

Replacement Decision Tree

  1. Is RS485 communication required?

Ja: Must choose S version or upgrade to communication-capable WM15 model

NEIN: Both S and X are acceptable; X is more cost-effective

  1. Does the system have existing communication infrastructure?

Ja: Prioritize S version to make full use of existing resources

NEIN: Choose X version to avoid redundant functions

Vorher:

Nächste:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen