ABB ESB25-22N-06 Building Contactor

ESB25-22N-06 ESB: ABB modular building installation contactor series 25: Rated operational current AC-1/AC-7a of main contacts = 25A 22: Kontaktkonfiguration: 2 Normalerweise geöffnet (NEIN) + 2 Normalerweise geschlossen (NC) (4-Pole) N: Silent AC/DC universal coil (no buzzing sound, built-in overvoltage absorption circuit) 06: Spulensteuerspannung: AC/DC 230~240V Original manufacturer part number: 1SAE231111R0622 Domestic ...

  • Produktdetails

ESB25-22N-06

  1. ESB: ABB modular building installation contactor Serie
  2. 25: Rated operational current AC-1/AC-7a of main contacts = 25A
  3. 22: Kontaktkonfiguration: 2 Normalerweise geöffnet (NEIN) + 2 Normalerweise geschlossen (NC) (4-Pole)
  4. N: Silent AC/DC universal coil (no buzzing sound, built-in overvoltage absorption circuit)
  5. 06: Spulensteuerspannung: AC/DC 230~240V

Original manufacturer part number: 1SAE231111R0622

Domestic order number: 10228794

  1. Grundlegende elektrische Spezifikationen

2.1 Main Circuit Load Ratings (400VAC/230VAC)

NutzungskategorieRated Current IeSingle-phase 230V Load Power
AC-1/AC-7a (Widerstandsfähig: Beleuchtung, Heizung)25A5.8kW
AC-3/AC-7b (Induktive Lasten: Motoren, Pumps)KEINE Kontakte: 9A / Öffnerkontakte: 6A1.3kW

Bemessungsisolationsspannung Ui: 500V

Bemessungsstoßspannungsfestigkeit Uimp: 6kV

Maximum main circuit voltage: 400V und / 220In DC

2.2 Control Coil

Steuerspannung: AC/DC 230~240V (universal for AC & Gleichstrom)

Applicable frequency: 50/60/400Hz

Merkmale: Silent operation, geringer Stromverbrauch, built-in surge suppression, no additional varistor required

2.3Mechanisch & Elektrische Ausdauer

Mechanische Ausdauer: 1,000,000 Operationen

Electrical endurance for AC-1 resistive loads: 130,000 Operationen

Electrical endurance for AC-3 motor loads: 500,000 Operationen

  1. Mechanische Abmessungen & Installation

Montagemethode: Snap-on mounting on standard 35mm DIN rail

Module width: 2 Module (36mm)

Gesamtabmessungen: W36mm × H85mm × D65mm

Nettogewicht: 0.245kg

Schutzklasse: IP20 (for indoor cabinet use only)

Beendigung: Schraubklemmen, tool-free auxiliary contact expansion interface

  1. Produktmerkmale
  2. Silent Coil: Universal for AC and DC, suitable for noise-sensitive areas such as machine rooms, dormitories and hotels
  3. Integrated Overvoltage Protection: Built-in absorption circuit on coil to suppress switching surges
  4. Wide Load Compatibility: Supports lighting, Fußbodenheizung, Fans, water pumps and small single-phase motors simultaneously
  5. Compact Modular Design: 2-module width to save cabinet space
  6. Equipped with 2NO and 2NC contacts, enabling synchronous control of two switch-on circuits and two switch-off circuits for flexible circuit design
  7. Typische Anwendungsszenarien

Gewerbebauten: Public lighting, central air conditioning fans, floor heating modules

Hotels & apartments: Automatic control of room lighting, fresh air systems and water pumps

Machine & electrical rooms: Thermostatic equipment, load switching in power distribution cabinets

Light industrial applications: Switching of resistive loads ≤25A and single-phase motors ≤1.3kW

  1. Optional Matching Accessories
  2. Hilfskontaktmodule: EH04-11N (1NO+1NC), EH04-20N (2NEIN)
  3. Spacing heat dissipation baffles: ESB-DIS (for multiple units installed side-by-side in high-temperature environments)
  4. End cover plates: ESB-PLK24, ESB-SPK24
  5. Reference Alternative Models in the Same Series

24V AC/DC coil: ESB25-22N-01

4NO with 230V coil: ESB25-40N-06

4NC with 230V coil: ESB25-04N-06

Complete Model List of ABB ESB Silent Building Contactors

  1. Modellkodierungsregel (ESBXX-XXN-XX)
  2. ESB: Silent AC/DC universal building contactor (built-in surge suppression, buzz-free)
  3. First two XX digits: Rated AC-1 current rating: 16/20/25/40/63/100A
  4. Middle two XX digits: Hauptkontaktkonfiguration (first = NO, second = NC)

11=1NO+1NC, 20=2NEIN, 02=2NC, 22=2NO+2NC, 40=4NO, 04=4NC

  1. N: Silent coil identifier
  2. Last two digits: Spulenspannungscode (2 commonly used versions in domestic market)

01: AC/DC 24V

06: AC/DC 230~240V (mainstream for civil use; your model ESB25-22N-06 adopts this voltage)

07: AC/DC 400~415V (for industrial three-phase control)

  1. Basic Specifications by Current Rating
ModellpräfixRated AC-1 CurrentModule WidthApplicable Loads
ESB1616A1 Modul (18mm)Small lighting, small electrical appliances
ESB2020A1 Modul (18mm)General lighting, Fans
ESB2525A2 Module (36mm)Floor heating, Wasserpumpen, Einphasenmotoren
ESB4040A3 Module (54mm)High-power heating, three-phase lighting
ESB6363A3 Module (54mm)Commercial central air conditioning, Hochleistungslasten
ESB100100A6 Module (108mm)Main control for large buildings, heavy three-phase loads
  1. Vollständige Modellliste nach aktueller Bewertung (Domestic common 01/06 Stromspannung, including industrial 07 Version)

3.1 ESB16 (16A, 1 Modul)

Contact configurations: 11, 20, 02

ESB16-11N-01 / ESB16-11N-06 / ESB16-11N-07

ESB16-20N-01 / ESB16-20N-06 / ESB16-20N-07

ESB16-02N-01 / ESB16-02N-06 / ESB16-02N-07

3.2 ESB20 (20A, 1 Modul)

Contact configurations: 11, 20, 02

ESB20-11N-01 / ESB20-11N-06 / ESB20-11N-07

ESB20-20N-01 / ESB20-20N-06 / ESB20-20N-07

ESB20-02N-01 / ESB20-02N-06 / ESB20-02N-07

3.3 ESB25 (25A, 2 Module, your model belongs to this series)

Contact configurations: 20, 02, 22, 40, 04

ESB25-20N-01 / ESB25-20N-06 / ESB25-20N-07

ESB25-02N-01 / ESB25-02N-06 / ESB25-02N-07

ESB25-22N-01 / ESB25-22N-06 / ESB25-22N-07 (your model ESB25-22N-06)

ESB25-40N-01 / ESB25-40N-06 / ESB25-40N-07

ESB25-04N-01 / ESB25-04N-06 / ESB25-04N-07

3.4 ESB40 (40A, 3 Module)

Contact configurations: 40, 04, 22

ESB40-40N-01 / ESB40-40N-06 / ESB40-40N-07

ESB40-04N-01 / ESB40-04N-06 / ESB40-04N-07

ESB40-22N-01 / ESB40-22N-06 / ESB40-22N-07

3.5 ESB63 (63A, 3 Module)

Contact configurations: 40, 04

ESB63-40N-01 / ESB63-40N-06 / ESB63-40N-07

ESB63-04N-01 / ESB63-04N-06 / ESB63-04N-07

3.6 ESB100 (100A, 6 Module)

Kontaktkonfiguration: 40

ESB100-40N-01 / ESB100-40N-06 / ESB100-40N-07

  1. Manual Operation Version EN Series (Optional, with manual toggle lever)

Same coding rule as ESB, prefixed with EN, z.B. EN20-22N-06, EN25-40N-06, for on-site manual switching and commissioning.

  1. Matching Accessory Part Numbers
  2. Hilfskontaktmodule: EH04-11N (1NO+1NC), EH04-20N (2NEIN)
  3. Side-by-side heat dissipation baffles: ESB-DIS
  4. End cover plates: ESB-PLK24 (for 1/2-module models), ESB-PLK40/63 (for 3/6-module models)
  5. Side sealing plates: ESB-SPK24, ESB-SPK40/63
  6. Cross Reference of Common Domestic Order Numbers (06 version with 230V coil)

ESB16-22N-06: 1SBE111111R0622

ESB20-22N-06: 1SBE121111R0622

ESB25-22N-06: 1SAE231111R0622 (Bestell-Nr.: 10228794)

ESB25-40N-06: 1SAE231111R0640 (Bestell-Nr.: 10228796)

ESB40-40N-06: 1SAE341111R0640

ESB63-40N-06: 1SAE351111R0640

Official Mechanical Endurance Parameters of ABB ESB25-22N-06

Mechanical Durability: 1,000,000 Operationen

Reference Supporting Electrical Endurance (Original Manufacturer Data for Same Model)

  1. Resistive loads AC-1 / AC-7a (Beleuchtung, Heizung)

Normalerweise geöffnet (NEIN) Kontakte: 130,000 Operationen

Normalerweise geschlossen (NC) Kontakte: 50,000 Operationen

  1. Motor loads AC-3 / AC-7b (Fans, Wasserpumpen)

Normalerweise geöffnet (NEIN) Kontakte: 500,000 Operationen

Normalerweise geschlossen (NC) Kontakte: 340,000 Operationen

Ergänzende Hinweise

  1. All models in ESB25 series (ESB25-20/02/22/40/04N-01/06/07) share a unified mechanical endurance of 1,000,000 Operationen, unaffected by contact configuration or coil voltage.
  2. Mechanical endurance refers to pure mechanical actuation cycles with no load, only coil pull-in and drop-out; electrical endurance means the effective service life of contacts under rated load switching.
  3. Ambient operating temperature range: -25℃ ~ +55℃. Temperatures exceeding 55℃ will shorten electrical endurance, while mechanical endurance is barely affected by minor temperature fluctuations.

Translation Specification Note

  1. Industrial electrical standard terms comply with IEC international norms (NO/Nc, AC-1/AC-3, DIN-Schiene, Dh, Ui, Uimp etc.)
  2. Marke, Modell, part numbers, order codes remain unchanged as original characters
  3. Tables, hierarchical titles, lists fully retain original document structure for engineering use
  4. Unit expressions follow international engineering writing habits (A, V, kW, mm, kg)

Vorher:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen