Schneider LC1E1801 Contactor

Erklärung des Modellcodes: LC1E = TeSys E series contactor; 18 = rated 18A at 400V under AC-3 duty; 01 = built-in 1 normalerweise geschlossener Kontakt (1NC) ⚠️ The LC1E series has been discontinued (production stopped in July 2020). The standard replacement model is LC1N1801, voll kompatibel in der Montage, terminal layout and performance. Key Specifications Main ...

  • Produktdetails

Erklärung des Modellcodes: LC1E = TeSys E series Schütz; 18 = rated 18A at 400V under AC-3 duty; 01 = built-in 1 normalerweise geschlossener Kontakt (1NC)

⚠️ The LC1E series has been discontinued (production stopped in July 2020). The standard replacement model is LC1N1801, voll kompatibel in der Montage, terminal layout and performance.

Wichtige Spezifikationen

Hauptkontakte: 3P, 3NEIN

AC-3 (motor duty): 18A bei 400 V; AC-1 (ohmsche Last): 25A

Motorleistung: 7.5kW @ 380/400V; 4kW bei 220 V; 9kW @ 440V

Isolationsspannung Ui: 690V; Stoßspannungsfestigkeit Uimp: 6kV

Hilfskontakt: 1NC (Normalerweise geschlossen)

Montage: DIN-Schiene / Schraubmontage der Grundplatte

Gesamtabmessungen: W45mm × H74mm × D80mm, net weight ≈0.3kg

Schutzklasse: IP20; Betriebstemperatur: -5~+55℃; No derating up to 3000m altitude

Mechanisches Leben: 10 Millionen Operationen; Elektrische Lebensdauer von AC-3: 1.2 Millionen Operationen; Maximale Betriebsfrequenz: 1800 Zyklen/Stunde

Coil suffix definitions (complete model number)

LC1E1801B5: AC24V, 50Hz

LC1E1801F5: AC110V, 50Hz

LC1E1801M5: AC220V, 50Hz (am häufigsten in China)

LC1E1801Q5: AC380V, 50Hz

Suffix 7 = 50/60Hz universal; Suffix 6 = 60Hz only

Stromverbrauch der Spule (M5 220V example)

Inrush VA: 95VA; Sealed holding VA: 8.5VA; Coil heat dissipation: 2~3W

Aufnahmespannung: 0.85~1.1Uc; Abfallspannung: 0.3~0.6Uc

Anzugsdrehmoment & wire gauge

Torque for main circuit and control circuit terminals: 1.2 N·m

Massiver Draht: 1.5~6mm²; Litzendraht (mit Zwinge): 1~4mm²

Matching selection reference

Passendes thermisches Überlastrelais: LRD07 / LRN07 (current range suitable for 18A)

Zubehör: LA1EN auxiliary contact block, LA9D coil surge suppressor, mechanical interlock block

Inländische Alternative: CJX2-1801 (similar outline, pay attention to mounting hole and marking differences)

Leitfaden zur Fehlerbehebung

  1. Spule unter Spannung, aber kein Einzug: Check if coil voltage is within 0.85~1.1Uc; inspect broken coil wire and loose terminals
  2. Pulled in but main circuit no continuity: Hauptkontakterosion, contact welding, lose Verkabelung
  3. Buzzing / chattering: Unterspannung, large harmonic distortion, dust accumulated on core faces
  4. Failed to drop out after power-off: Geschweißte Hauptkontakte, core stuck by oil and dirt

Detailed Installation Procedure for Schneider LC1E1801 Contactor

⚠️ Safety precondition: Operated by qualified electricians; cut off all power supply and verify zero voltage before installation. LC1E1801: 3P main contacts with built-in 1NC auxiliary contact. Klemmenmarkierung: Hauptstromkreis L1/L2/L3 (line side, incoming), T1/T2/T3 (Lastseite, outgoing); Coil A1, A2; Hilfskontakt: 95, 96 (1NC)

  1. Vorbereitung vor der Installation
  2. Überprüfen Sie die Spulenspannung: LC1E1801M5=AC220V, Q5=AC380V, F5=AC110V. Coil rated voltage must match control circuit voltage to avoid coil burnout.
  3. Sichtprüfung: No shell cracks, intact terminals, armature moves freely without jamming when pressed manually.
  4. Werkzeuge: 2 Kreuzschlitzschraubendreher, Abisolierzange, Multimeter, Drehmomentschlüssel; 35mm standard DIN rail or mounting base plate.
  5. Wire specification

Main circuit solid wire: 1.5~6mm²; Stranded wire with ferrule: 1~4mm²

Steuerkreis (A1/A2, Hilfskontakte): 0.75~1.5mm²

Anzugsdrehmoment: 1.2 N·m (avoid over-tightening to prevent thread stripping, or loose connection causing overheating)

  1. Environmental check: Cabinet temperature -5℃~+55℃, keep away from dust, Feuchtigkeit und Öl. Mount vertically upright. Do NOT install upside down or horizontally.
  2. Festsetzung (2 methods: DIN-Schiene / Schraubmontage der Grundplatte)

Verfahren 1: 35mm DIN-Schienenmontage (bevorzugt)

  1. The contactor has upper hooks and a spring locking clip at the bottom.
  2. Hook the upper notch onto the top edge of the DIN rail first.
  3. Press the bottom of the contactor down until you hear a click, the bottom clip locks onto the rail.
  4. Shake lightly to confirm firm fixation. Entfernung: Use a flat screwdriver to pry down the bottom clip and pull out the contactor.

Verfahren 2: Screw mounting on insulated base plate (no rail)

  1. Mark and drill holes on the insulated plate according to the rear mounting holes (for M4 screws).
  2. Insert screws diagonally, pre-tighten, then torque evenly in diagonal sequence; do not force one side to avoid casing deformation.
  3. Accessory Fitting (Optional: LA1EN auxiliary block, mechanical interlock etc.)
  4. Top auxiliary contact block: Align with the slots on top of contactor, push vertically down until latched.
  5. Thermal relay LRD/LRN: Clip directly underneath the contactor, align positioning slots; the linkage will engage automatically.
  6. Surge suppressor LA9D: Clip beside coil terminals A1/A2, absorbs back EMF to protect PLC output points.
  7. Verdrahtungsreihenfolge (Main circuit → Auxiliary contacts → Coil control circuit)

Standard routing: Line side on top, load side on bottom. L1/L2/L3 on top for three-phase supply; T1/T2/T3 at bottom for load (Motor).

  1. Verkabelung des Hauptstromkreises

Strip insulation 5~6mm, avoid loose copper strands; ferrules are mandatory for stranded wire.

Keep phase sequence L1→T1, L2→T2, L3→T3 as per drawing.

Torque screws to 1.2N·m; only one conductor per terminal.

  1. Built-in auxiliary contact (95-96, NC)

Terminals 95-96: Conductive when coil de-energized, open when contactor pulls in. Usually used in stop circuit or fault feedback for motor control.

If NO contact is required, add LA1EN auxiliary block.

  1. Coil A1, A2 (Steuerkreis)

A1 and A2 have no polarity for AC. For AC220V: one to live, one to neutral; for AC380V: connect to two different phases.

Wire in series with start/stop pushbuttons, thermal relay NC contact or PLC outputs.

Route control wires separately from power cables to reduce interference.

Terminal summary:

L1/L2/L3 (Supply In), T1/T2/T3 (Load Out), A1 A2 (Spule), 95-96 (Eingebauter 1NC)

  1. Inspektion vor dem Einschalten
  2. Visuelle Kontrolle: All terminals tightened, no exposed copper, no short circuit risk, no loose strands touching adjacent terminals.
  3. Durchgangsprüfung mit Multimeter:

Spannungsloser Zustand: No continuity between L-T; 95-96 auxiliary contact is conductive.

Manually press armature to simulate pull-in: L-T becomes conductive, 95-96 öffnet sich.

  1. Double-check coil voltage; separate power supply for main circuit and control circuit.
  2. Inbetriebnahme beim Einschalten
  3. Energize control circuit only, keep main power off: Press start button, contactor should pull-in smoothly without chattering or buzzing; release stop button for reliable drop-out.

Geschwätz: Niedrige Versorgungsspannung, loose wiring or dirty core surfaces.

  1. After control circuit test passes, energize main circuit and run on load.
  2. Temperature check after 10min running: No obvious overheating at terminals (temperature rise indicates poor connection).
  3. Installationshinweise & Verbote
  4. Keep minimum clearance ≥10mm between contactor and fuse / MCB for heat dissipation.
  5. Minimum spacing ≥5mm between multiple contactors; increase spacing for high ambient temperature.
  6. Do not plug or remove auxiliary blocks when energized.
  7. Do not trap wire insulation inside terminal clamps; copper must be fully clamped.
  8. LC1E discontinued, spare replacement: LC1N1801, same mounting size and terminal definition.
  9. Common Installation Faults

No pull-in after energized: Wrong A1/A2 voltage, broken control wire or open button circuit

Buzzing when pulled in: Unterspannung, dust or rust on magnetic core faces

Cannot drop out after power cut: Welded main contacts or core jammed by oil

Schneider Easy TeSys E (LC1E / EasyPact-Fernseher) Series Full List

Wichtiger Hinweis: LC1E series fully discontinued in July 2020. Direkter Ersatz: LC1N series, identische Einbaumaße und Klemmenanordnung.

Modellregel: LC1E + current code + auxiliary contact code (10=1NEIN; 01= 1 NC) + coil suffix

Coil suffix description:

B5=AC24V 50Hz; F5=AC110V 50Hz; M5=AC220V 50Hz; Q5=AC380V 50Hz

B7/F7/M7/Q7=50/60Hz universal; BD=DC24V; 6=60Hz only

  1. 3P LC1E Contactors (AC-3 bei 400 V)
BasismodellAC-3-StromMotor Rating @400VBuilt-in Auxiliary Contact
LC1E06106A2.2kW1NEIN
LC1E06016A2.2kW1NC
LC1E09109A4kW1NEIN
LC1E09019A4kW1NC
LC1E121012A5.5kW1NEIN
LC1E120112A5.5kW1NC
LC1E181018A7.5kW1NEIN
LC1E180118A7.5kW1NC (your referenced model)
LC1E251025A11kW1NEIN
LC1E250125A11kW1NC
LC1E321032A15kW1NEIN
LC1E320132A15kW1NC
LC1E381038A18.5kW1NEIN
LC1E380138A18.5kW1NC
LC1E401140A18.5kW1NO+1NC
LC1E501150A22kW1NO+1NC
LC1E651165A30kW1NO+1NC
LC1E801180A37kW1NO+1NC
LC1E951195A45kW1NO+1NC
LC1E120120A55kWKein eingebauter, add auxiliary block separately
LC1E160160A75kWKein eingebauter, add auxiliary block separately
LC1E200200A90kWKein eingebauter, add auxiliary block separately
LC1E300300A160kWKein eingebauter, add auxiliary block separately

Example complete model: LC1E1801M7 = 18A, 1NC, AC220V 50/60Hz universal

  1. Matching LRE Thermal Overload Relays (plug-on fit for LC1E)

LRE01N~LRE35N (for 06~38A); LRE322N~LRE365N (for 40~300A)

LRE01N: 0.1~0.16A

LRE02N: 0.16~0.25A

LRE03N: 0.25~0.4A

LRE04N: 0.4~0.63A

LRE05N: 0.63~1A

LRE06N: 1~1,6A

LRE07N: 1.6~2,5A

LRE08N: 2.5~4A

LRE09N: 4~6A

LRE10N: 6~10A

LRE12N: 10~16A

LRE14N: 16~24A

LRE16N: 24~36A

LRE21N: 28~36A

LRE22N: 36~48A

LRE322N: 55~70A

LRE323N: 63~80A

LRE353N: 80~104A

LRE355N: 104~135A

LRE365N: 130~165A

  1. E-series Accessories
  2. LA1EN: Top-mounted auxiliary contact block (1NEIN / 1NC, stackable)
  3. LAEM1: Mechanisches Verriegelungsmodul (for two contactor interlocking)
  4. LA9D: Spulen-Überspannungsschutz (RC-Netzwerk / Varistor, PLC output protection)
  5. LAEB1N / LAEB3N: Thermal relay independent base (when not mounted under contactor)
  6. LA1EBN: Timed auxiliary contact block (Einschaltverzögerung / Ausschaltverzögerung)
  7. 2P / 4P LC1E (single phase, Beleuchtung & ohmsche Last, AC-1-Dienst)

LC1E0920: 2F 9A

LC1E2520: 2P 25A

LC1E0940: 4F 9A

LC1E2540: 4P 25A

LC1E4040: 4P 40A

4P versions commonly used for HVAC, lighting and heating resistive loads

  1. Cross Reference Table
Old LC1E ModelDirect Replacement LC1N
LC1E0601/0610LC1N0601 / LC1N0610
LC1E0901/0910LC1N0901 / LC1N0910
LC1E1201/1210LC1N1201 / LC1N1210
LC1E1801/1810LC1N1801 / LC1N1810
LC1E2501/2510LC1N2501 / LC1N2510
LC1E3201/3210LC1N3201 / LC1N3210
LC1E3801/3810LC1N3801 / LC1N3810
LC1E40~95LC1N40~95

Vorher:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen