ABB Leistungsfaktorregler 2GCA294985A0050 - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Stromzähler/elektrisch/

ABB Leistungsfaktorregler 2GCA294985A0050

The model 2GCA294985A0050 is not a display screen, but rather an ABB RVC-8 Power Factor Controller (also known as a Reactive Power Compensation Controller). It is used to automatically control the switching of capacitor banks, optimize the power factor of the power grid, and reduce energy consumption and electricity penalty charges due to poor power ...

  • Produktdetails

The model 2GCA294985A0050 is not a display screen, but rather an ABB RVC-8 Power Factor Controller (also known as a Reactive Power Compensation Controller). It is used to automatically control the switching of capacitor banks, optimize the power factor of the power grid, and reduce energy consumption and electricity penalty charges due to poor power factor.

  1. Core Product Information
ArtikelDetaillierte Spezifikationen
ModellRVC-8 (2GCA294985A0050), Old Order No.: 10148029
Product Type8-output Power Factor Controller
Spannungsbereich100V~440V, suitable for most low-voltage power grids
Input Current1A oder 5A (RMS), requires connection to a Current Transformer (CT)
FrequenzbereichAuto-adapts to 50/60Hz
Display TypeBlack and white LCD display with functional icons
SteuermodusFully automatic control, supporting multiple switching strategies such as Integral, Cyclic, and Direct
Betriebstemperatur-25°C~+70°C (ambient); Triggers an alarm if internal temperature exceeds 85°C
StromverbrauchMax 8VA
Output Circuits8 programmable relay outputs, each rated at 16A/250VAC
  1. Core Functional Features
  2. Comprehensive Parameter Monitoring:

Measures and displays key grid parameters including voltage, aktuell, Leistungsfaktor, THDV (Total Harmonic Voltage Distortion), and THDI (Total Harmonic Current Distortion).

  1. Flexible Control Strategies:

Fully programmable switching sequence supporting both共补 (Total Phase Compensation) and 分补 (Individual Phase Compensation).

Switching interval adjustable from 1 second to 999 Sekunden.

Target power factor adjustable from 0.7 (inductive) Zu 0.7 (capacitive).

Auto-adapts to grid phase sequence and CT terminal connection.

  1. Multiple Protection Functions:

Over-voltage / Under-voltage protection.

Over-temperature protection (internal temperature > 85°C).

Excessive harmonic protection (THDV threshold超限).

Power-off memory function (maintains capacitor bank state for power off durations up to 40ms).

  1. User-friendly Interface:

Upgraded icon-based UI allows for quick commissioning without a manual. The compact design saves cabinet space.

  1. Anwendungsszenarien

Industrial Plants: Reactive power compensation for inductive loads such as inverters, Kompressoren, and motors.

Commercial Complexes: Reactive current compensation for devices like central air conditioners and elevators.

Data Centers: Stabilize the power supply system and improve energy efficiency.

New Energy Power Stations: Optimize the reactive power output of photovoltaic inverters and wind turbine converters to improve grid connection efficiency.

Public Facilities: Power distribution systems for public buildings such as hospitals, schools, and subway stations.

  1. RVC Series Full Model Comparison
ModellBestell-Nr.Number of Output CircuitsMain Features
RVC-32GCA294983A00503-circuitSuitable for small capacitor cabinets
RVC-62GCA294984A00506-circuitMedium-scale capacitor compensation system
RVC-82GCA294985A00508-circuitThis product; suitable for medium and large capacitor cabinets
RVC-102GCA294986A005010-circuitLarge-scale capacitor compensation system
RVC-122GCA294987A005012-circuitExtra-large scale capacitor compensation system
RVC-L-122TAZ460104R112012-circuitLong-life version, replacing the old RVC-12
RVT-L-182TAZ460103R018018-circuitDedicated to 3-phase individual compensation, unterstützt 18 output circuits
  1. Replacement Solutions
  2. ABB Original Factory Upgrade Replacements:

RVC-L Series: Long-life version, z.B., RVC-L-12 (replaces RVC-12).

RVT Series: More advanced power factor controllers with support for more functions and communication protocols.

  1. Other Brand Replacements:

Schneider: VPL06N/VPL12N series.

Siemens: 7KM series power factor controllers.

Domestic Replacements: Similar products from brands such as Chint and Delixi.

  1. Technical Documentation and Support
  2. Notizen: The RVC-8 has been discontinued. It is recommended to prioritize upgrading to the RVC-L series or RVT series products for better performance and a longer service life.

Complete List of ABB Power Factor Controller Models and Comparison with Mainstream Brands

  1. Complete List of ABB Power Factor Controller Models
  2. RVC Series (Discontinued; recommended upgrade to the RVC-L series)
ModellBestell-Nr. (New/Old)Number of OutputsCore SpecificationsAnwendungsszenarien
RVC-32GCA294983A0050/101480273-circuit100-440V und, 1/5A CT, IP20Small capacitor cabinets, stable load systems
RVC-62GCA294984A0050/101480286-circuit100-440V und, 1/5A CT, IP20Medium compensation systems, Gewerbebauten
RVC-82GCA294985A0050/101480298-circuit100-440V und, 1/5A CT, IP20Medium and large compensation systems, industrial plants
RVC-102GCA294986A0050/1014803010-circuit100-440V und, 1/5A CT, IP20Large compensation systems, Rechenzentren
RVC-122GCA294987A0050/1014803112-circuit100-440V und, 1/5A CT, IP20Extra-large compensation systems, new energy power stations

Kernfunktionen: Black and white LCD icon-based UI, supports Integral/Cyclic/Direct control, includes THDV/THDI monitoring, and features Over-voltage/Under-voltage/Harmonic/Over-temperature protection.

  1. RVC-L Series (RVC upgrade, long-life design)
ModellBestell-Nr.Number of OutputsCore SpecificationsUpgrade Advantages
RVC-L-32TAZ460104R00303-circuit100-440V und, 1/5A CT, IP20Extended service life, optimized algorithms
RVC-L-62TAZ460104R00606-circuit100-440V und, 1/5A CT, IP20Extended service life, optimized algorithms
RVC-L-82TAZ460104R00808-circuit100-440V und, 1/5A CT, IP20Extended service life, optimized algorithms
RVC-L-102TAZ460104R010010-circuit100-440V und, 1/5A CT, IP20Extended service life, optimized algorithms
RVC-L-122TAZ460104R112012-circuit100-440V und, 1/5A CT, IP20Extended service life, optimized algorithms; most widely used

Kernfunktionen: Retains all RVC functionality with improved component quality, extended MTBF (Mean Time Between Failures), and greater stability and reliability.

  1. RVT Series (Advanced features, supporting individual phase compensation)
ModellBestell-Nr.Number of OutputsCore SpecificationsKernfunktionen
RVT-6100791826-circuit100-460V und, 1/5A CTIntegral/Cyclic/Direct control, individual/total phase compensation, Oberwellenüberwachung
RVT-121007916112-circuit100-460V und, 1/5A CTIntegral/Cyclic/Direct control, individual/total phase compensation, Oberwellenüberwachung
RVT-12-3PCustom12-circuit100-460V und, 1/5A CT3-phase independent measurement, energy calculation, support for all connection types

Kernfunktionen: More precise measurement, support for 3-phase unbalanced systems, independent measurement of each phase, suitable for complex load environments.

  1. RVT-L Series (Latest touchscreen series, most powerful features)
ModellBestell-Nr.Number of OutputsControl TypeKernvorteile
RVT-L-18 3P(N)2TAZ460103R018018-circuitContactor switching (passive)Touchscreen UI, 3-phase full parameter measurement, harmonic spectrum analysis
RVT-L-18 3P(T)Custom18-circuitThyristor switching (active DC12V)Dynamic compensation, fast response to impact loads
RVT-L-24 3P(N)Custom24-circuitContactor switching (passive)Maximum number of output circuits, suitable for extra-large systems
RVT-L-24 3P(T)Custom24-circuitThyristor switching (active DC12V)Dynamic compensation, maximum number of output circuits

Kernfunktionen: Color touchscreen, 18/24 output circuits, support for low/medium voltage applications, optional Modbus communication, suitable for high-end projects and smart grids.

  1. Comparison List of Mainstream Brand Power Factor Controllers (Categorized by Number of Output Circuits)
Number of OutputsABBSchneiderSiemensChintLeckerMain Feature Comparison
3-circuitRVC-L-3VPL03N7KM2111NWKL1-3JKL2B-3ABB/RVC-L: Harmonic monitoring; Schneider: Modular design; Siemens: Strong communication; Inländisch: High cost-performance ratio
6-circuitRVC-L-6VPL06N7KM2112NWKL1-6JKL2B-6ABB: Flexible switching strategies; Schneider: Plug-and-play; Siemens: Strong diagnostic capabilities
8-circuitRVC-L-8VPL08N7KM2113ZT-830-8JKL5C-8ABB: Integral/Cyclic/Direct 3 modes; Inländisch: Significant cost advantage
12-circuitRVC-L-12VPL12N/NVPL12N7KM2114NWKL1-12JKL2C-12ABB: Over-temperature protection; Schneider: 24V auxiliary power; Siemens: Detailed fault records
18-circuitRVT-L-18NVPL18N/NVPL18T7KM2318ZT-830-18CustomABB/RVT-L: Touchscreen; Schneider: Contactor/Thyristor dual version; Siemens: Advanced algorithms
24-circuitRVT-L-24NVPL24N/NVPL24T7KM2324CustomCustomABB/RVT-L: Harmonic spectrum; Schneider: Maximum number of circuits; Siemens: Industrial network integration
  1. Comparison Table of Core Technical Characteristics by Brand
MarkeRepräsentative SerieKernvorteileDisadvantagesAnwendungsszenarien
ABBRVC-L/RVT-LHigh measurement accuracy, comprehensive protection, strong harmonic analysis, lange lebensdauerHigher price, some models require customizationIndustrielle Automatisierung, new energy, high-end commercial projects
SchneiderVPL/NVPLModular design, plug-and-play, rich communication protocolsGeneral harmonic processing capabilityGewerbebauten, Rechenzentren, infrastructure
Siemens7KMPowerful diagnostic functions, excellent industrial network integration, advanced algorithmsComplex operation, steep learning curveSchwerindustrie, power systems, large factories
ChintNWKL1/ZT-830High cost-performance ratio, einfache Bedienung, compatible with domestic power gridsFew high-end features, limited communication optionsSmall and medium enterprises, civil construction, renovation projects
LeckerJKL2B/JKL5CAffordable price, good reliability, comprehensive after-sales serviceLack of advanced algorithms, weak harmonic monitoringSmall factories, Geschäfte, residential power distribution
  1. Selection Guidelines and Replacement Recommendations
  2. RVC Series Upgrade: Existing RVC users are recommended to directly upgrade to the corresponding RVC-L model to maintain compatibility of control logic and obtain a longer service life and more stable performance.
  3. Selection of Number of Circuits: Select the number of circuits based on 1.2 times the total reactive power of the system, and reserve 2-3 circuits for future load increases.
  4. Control Type Selection:

Stable Loads: Choose contactor switching (Typ N) for low cost and long service life.

Impact Loads: Choose thyristor switching (Type T) for fast response and no inrush current.

  1. Harmonic Considerations: If the system THDV > 5%, it is recommended to select a model with harmonic protection functions (such as ABB RVT-L, Schneider NVPL), and use it in conjunction with reactors.
  2. Quick Reference Table of Technical Parameters (Universal for the entire series)
ParameterkategorieTypical ValueNotizen
Betriebsspannung100-440V und (RVC/RVC-L), 85-305V und (RVT-L)Großer Spannungsbereich, compatible with global power grids
Current Input1A or 5A CT (RMS)Requires connection to a Current Transformer
Frequency AdaptationAuto-adapts to 50/60HzNo manual setting required
Target Power FactorAdjustable from 0.7 (inductive) Zu 0.7 (capacitive)Meets requirements of different power grids
Switching IntervalAdjustable from 1 second to 999 SekundenIndependent of load changes
SchutzfunktionenOver-voltage/Under-voltage/Harmonic/Over-temperature/Power-off memoryComprehensive protection for capacitors and the power grid
InstallationsmethodeDIN rail installation (Breite: standard 96mm)Spart Platz im Schrank