Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

ABB Softstarter PSE370-600-70-1 - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Solarwechselrichter/Stromzähler/elektrisch/

ABB Softstarter PSE370-600-70-1

Modellaufschlüsselung & Basic Information Model Part Description PSE Series designation, ABB economy soft starter, adopting two‑phase control technology 370 Rated maximum operational current: 370A 600 Rated voltage range: 208~600V AC 70 Control voltage: 100~250V AC (50/60Hz) 1 Version identifier Order No. 1SFA897115R7001 Protection Degree IP00 (basic installation) Control Method Two‑phase control, soft start and soft stop ...

  • Produktdetails

Modellaufschlüsselung & Grundlegende Informationen

ModellteilBeschreibung
PSESeries designation, ABB economy soft starter, adopting two‑phase control technology
370Rated maximum operational current: 370A
600Rated voltage range: 208~600V AC
70Control voltage: 100~250V AC (50/60Hz)
1Version identifier
Bestell-Nr.1SFA897115R7001
SchutzgradIP00 (basic installation)
Control MethodTwo‑phase control, soft start and soft stop via voltage or torque ramps
  1. Technische Kernparameter

2.1 Elektrische Parameter

ParameterWertBemerkungen
Rated operational current (Iₑ)370AIn-line connection
Suitable motor power230V: 110kWPower ratings at different voltage levels
400V: 200kW
500V: 250kW
600V: 350HP (ca. 260kW)
Maximum starting current4×Iₑ for 10 SekundenCompliant with IEC standards
Control voltage (Uₛ)100~250V AC / 24In DCDual‑voltage compatible
Frequenz50/60HzGlobal universal
Built-in bypassStandard, reduces energy consumption and heat dissipationAutomatically switches after soft start completion
Power factor0.95 (in bypass operation)High-efficiency operation

2.2 Mechanisch & Environmental Parameters

ParameterWert
GewichtCa. 27.28 lbs (12.37 kg)
MontageStandard DIN rail or bolt mounting
Betriebstemperatur-25°C ~ +60°C
Storage temperature-40°C ~ +85°C
SchutzgradIP00 (unit itself); recommended installation in IP54 or higher control cabinet
  1. Merkmale & Funktionen

3.1 Steuerfunktionen

Soft start modes: Voltage ramp control, torque ramp control

Soft stop modes: Voltage ramp stop, torque ramp stop

Current-limited start: Adjustable starting current limit to protect the grid and motor

Kick Start: For heavy-duty starting applications

Sequential starting: Supports sequential control of multiple motors

Auto restart: Automatically resumes operation after fault clearance

Reverse start: Requires external contactors

3.2 Schutzfunktionen

Electronic Overload Protection (EOL): Adjustable 30~100% Iₑ

Locked-rotor protection: Prevents motor burnout due to stalling

Underload protection: Monitors motor underload operation

Phase loss protection: Detects three-phase power loss

Overtemperature protection: Protects the soft starter from overheating

Phase imbalance protection: Prevents motor damage from unbalanced three-phase currents

3.3 Monitoring & Kommunikation

Language-neutral display: Symbol-based user interface, no language setup required

Relay outputs: RUN, TOR (Drehmoment), and Event signals (KEINE Kontakte)

Built-in Modbus RTU communication: Supports industrial network integration

Optional external keypad: IP66 protection, geeignet für raue Umgebungen

  1. Anwendungen

The PSE370-600-70-1 is designed for smooth starting and protection of light to medium-duty three-phase asynchronous motors. Typical applications include:

  1. Pump systems: Prevents water hammer, protects pipes and valves
  2. Fan systems: Reduces mechanical stress and grid impact
  3. Compressors: Smooth starting, extends equipment service life
  4. Förderer: Avoids material spillage, ensures stable process control
  5. Allgemeine industrielle Anwendungen: General machinery requiring soft start/stop

Especially suitable for: Applications requiring basic soft start functions, limited budget, and compact space. The built-in bypass simplifies installation and lowers operating costs.

  1. Comparison with Other Models in the Same PSE Series
ModellNennstromSuitable Power @400V
PSE18-600-7018A7.5kW
PSE30-600-7030A15kW
PSE45-600-7045A22kW
PSE60-600-7060A30kW
PSE90-600-7090A45kW
PSE132-600-70132A75kW
PSE170-600-70170A90kW
PSE210-600-70210A110kW
PSE250-600-70250A132kW
PSE370-600-70-1370A200kW
  1. Alternativen & Upgrade Paths
Alternatives ModellSerieMerkmaleAnwendung
PSTX370-600-70PSTX SeriesThree‑phase control, full graphic display, advanced functions (jog, braking, diagnostics)Requires precise control and diagnostics
PSTB370-600-70PSTB SeriesBuilt-in Modbus TCP/IP, higher protection, ideal for network integrationIndustrie 4.0 smart factories
PSR370-600-70PSR SeriesMore economical basic version, soft start/stop onlySimple applications with limited budget

6.2 Cross-Brand Alternatives

MarkeEmpfohlenes ModellKompatibilität
SchneiderATS48D37Q370A rated current, similar functions
Siemens3RW4443-6BC44370A, integrated protection functions
ABBPSE370-600-70 (Basisversion, Bestell-Nr. 1SFA897115R7000)Fully compatible
  1. Installation & Wiring Notes
  2. Main circuit connection: Three-phase supply (L1/L2/L3) → Soft starter → Motor. Copper cable recommended; tighten terminals to specified torque.
  3. Control circuit connection:

100~250V AC control supply

Start/stop signals (dry contacts)

Fault reset signal

Relay output signals (run/fault indication)

  1. Communication connection: Connect to PLC or HMI via Modbus RTU interface
  2. Cooling requirements: Install in well-ventilated area with sufficient clearance for heat dissipation
  3. Auswahlempfehlungen
  4. Select soft starter based on motor rated current (recommended Iₑ ≥ motor rated current)
  5. For heavy-duty starting (z.B., Brecher, ball mills), PSTX Series three-phase control is recommended
  6. Upgrade recommended for frequent starting (>10 starts/hour) or precise torque control
  7. For network integration, choose PSTB Series with Modbus TCP/IP

The PSE370-600-70-1 is the largest economy soft starter in the ABB PSE series, providing reliable motor soft starting and basic protection with high cost-performance, suitable for most industrial applications.

Complete Model List & Order Numbers for ABB Soft Starters

  1. Modellbenennungskonvention

ABB soft starter models generally follow the format:

Series-Rated Current-Rated Voltage-Control Voltage(-Version)

ModellteilBeschreibung
SeriePSR (Kompakt), PSE (Easy‑Use), PSTX (Full‑Intelligent), PSTB (Smart)
NennstromRated operational current of soft starter (A)
NennspannungMain circuit voltage range (208~600V or 208~690V)
Control Voltage70 = 100~250V AC; 11 = 24V DC
Version0 = Basic version; 1 = Upgraded version (selected series)

Order number format: 1SFA89XXXXR7000 (XXXX = series-specific code)

  1. PSE Series (Easy-Use, Two-Phase Control, Built-in Bypass & Electronic Overload Protection)

Nennspannung: 208~600V AC, control voltage: 100~250V AC, order prefix: 1SFA8971

ModellNennstromSuitable Power @400VBestell-Nr.
PSE18-600-7018A7.5kW1SFA897101R7000
PSE25-600-7025A11kW1SFA897102R7000
PSE30-600-7030A15kW1SFA897103R7000
PSE37-600-7037A18.5kW1SFA897104R7000
PSE45-600-7045A22kW1SFA897105R7000
PSE60-600-7060A30kW1SFA897106R7000
PSE72-600-7072A37kW1SFA897107R7000
PSE85-600-7085A45kW1SFA897108R7000
PSE105-600-70105A55kW1SFA897109R7000
PSE132-600-70132A75kW1SFA897113R7000
PSE170-600-70170A90kW1SFA897111R7000
PSE210-600-70210A110kW1SFA897112R7000
PSE250-600-70250A132kW1SFA897113R7000
PSE250-600-70-1250A132kW1SFA897113R7001
PSE300-600-70300A160kW1SFA897114R7000
PSE300-600-70-1300A160kW1SFA897114R7001
PSE370-600-70370A200kW1SFA897115R7000
PSE370-600-70-1370A200kW1SFA897115R7001
  1. PSR Series (Kompakt, Two-Phase Control, Basic Soft Start/Stop)

Nennspannung: 208~600V AC, control voltage: 70 (100~250V AC) / 11 (24In DC), order prefix: 1SFA8961

ModellNennstromSuitable Power @400VControl VoltageBestell-Nr.
PSR3-600-703A1.1kW100~250V AC1SFA896101R7000
PSR6-600-706A2.2kW100~250V AC1SFA896102R7000
PSR9-600-709A3kW100~250V AC1SFA896103R7000
PSR12-600-7012A4kW100~250V AC1SFA896106R7000
PSR18-600-7018A7.5kW100~250V AC1SFA896107R7000
PSR25-600-7025A11kW100~250V AC1SFA896108R7000
PSR30-600-7030A15kW100~250V AC1SFA896109R7000
PSR37-600-7037A18.5kW100~250V AC1SFA896110R7000
PSR45-600-7045A22kW100~250V AC1SFA896111R7000
PSR57-600-7057A30kW100~250V AC1SFA896112R7000
PSR72-600-7072A37kW100~250V AC1SFA896113R7000
PSR85-600-7085A45kW100~250V AC1SFA896114R7000
PSR105-600-70105A55kW100~250V AC1SFA896115R7000
  1. PSTX Series (Full-Intelligent, Three-Phase Control, Full Graphic Display, Advanced Functions)

Nennspannung: 208~690V AC, control voltage: 100~250V AC, order prefix: 1SFA8982

ModellNennstromSuitable Power @400VSuitable Power @690VBestell-Nr.
PSTX30-690-7030A15kW25kW1SFA898203R7000
PSTX45-690-7045A22kW37kW1SFA898204R7000
PSTX60-690-7060A30kW45kW1SFA898206R7000
PSTX72-690-7072A37kW55kW1SFA898207R7000
PSTX85-690-7085A45kW75kW1SFA898208R7000
PSTX105-690-70105A55kW90kW1SFA898209R7000
PSTX142-690-70142A75kW132kW1SFA898210R7000
PSTX170-690-70170A90kW160kW1SFA898211R7000
PSTX210-690-70210A110kW200kW1SFA898212R7000
PSTX250-690-70250A132kW250kW1SFA898213R7000
PSTX300-690-70300A160kW315kW1SFA898214R7000
PSTX370-690-70370A200kW355kW1SFA898215R7000
PSTX470-690-70470A250kW400kW1SFA898216R7000
PSTX570-690-70570A315kW500kW1SFA898217R7000
PSTX640-690-70640A355kW560kW1SFA898218R7000
  1. PSTB Series (Smart, Built-in Modbus TCP/IP, Network Integration)

Nennspannung: 208~600V AC, control voltage: 100~250V AC, order prefix: 1SFA8940

ModellNennstromSuitable Power @400VBestell-Nr.
PSTB37-600-7037A18.5kW1SFA894003R7000
PSTB45-600-7045A22kW1SFA894004R7000
PSTB60-600-7060A30kW1SFA894005R7000
PSTB72-600-7072A37kW1SFA894006R7000
PSTB85-600-7085A45kW1SFA894007R7000
PSTB105-600-70105A55kW1SFA894008R7000
PSTB142-600-70142A75kW1SFA894009R7000
PSTB170-600-70170A90kW1SFA894010R7000
PSTB210-600-70210A110kW1SFA894011R7000
PSTB250-600-70250A132kW1SFA894012R7000
PSTB300-600-70300A160kW1SFA894013R7000
PSTB370-600-70370A200kW1SFA894015R7000
PSTB470-600-70470A250kW1SFA894016R7000
PSTB570-600-70570A315kW1SFA894017R7000
PSTB720-600-70720A400kW1SFA894018R7000
PSTB840-600-70840A450kW1SFA894019R7000
  1. Auswahlhilfe & Alternativen
  2. Series Selection Guide

Simple applications, limited budget: PSR Series (basic soft start/stop)

Pumps, fans and light-medium loads: PSE Series (built-in electronic overload protection)

Precise control and diagnostics: PSTX Series (three-phase control, full graphic display)

Industrie 4.0 smart factories: PSTB Series (built-in Modbus TCP/IP)

  1. Cross-series substitution

PSE370-600-70-1 alternatives:

Upgrade: PSTX370-690-70 (Bestell-Nr. 1SFA898215R7000)-three-phase control, more advanced functions

Downgrade: PSR105-600-70 (Bestell-Nr. 1SFA896115R7000)-Grundfunktionen, more economical

  1. Cross-brand alternatives

Schneider: ATS48D37Q (370A, similar functions)

Siemens: 3RW4443-6BC44 (370A, integrated protection)

  1. All above models are standard versions; special versions required for harsh environments (high altitude, high humidity)
  2. Verify control voltage matches main circuit voltage before ordering
  3. For frequent starting (>10 starts/hour) or heavy-duty applications, PSTX/PSTB Series three-phase units are recommended
  4. Full specifications and latest pricing subject to ABB official catalog

Vorher:

Nächste:

Hinterlassen Sie eine Antwort