Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

Chint CJX2-9511 AC Contactor - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Schütz/

Chint CJX2-9511 AC Contactor

Model SegmentBedeutung
CJX2Chint AC contactor series code (equivalent and compatible with Schneider LC1D series)
95Rated operating current of 95A (under AC-3 utilization category at 400V)
11Auxiliary contact configuration: 1 Normalerweise geöffnet (NEIN) + 1 Normalerweise geschlossen (NC)

  • Produktdetails

Kernpositionierung: The Chint CJX2-9511 is a 3-pole AC-Schütz with a rated current of 95A, equipped with 1 normalerweise offen (NEIN) + 1 normalerweise geschlossen (NC) Hilfskontakt. It is suitable for AC 50/60Hz circuits, mainly used for remote switching on/off of circuits, frequent starting and control of three-phase AC motors. It can be combined with a thermal overload relay to form an electromagnetic starter for overload protection.

  1. Modellinterpretation
Model SegmentBedeutung
CJX2Chint AC contactor series code (equivalent and compatible with Schneider LC1D series)
95Rated operating current of 95A (under AC-3 utilization category at 400V)
11Auxiliary contact configuration: 1 Normalerweise geöffnet (NEIN) + 1 Normalerweise geschlossen (NC)
  1. Technische Kernparameter
ParameterelementSpecification Details
Contactor TypeAC coil contactor, 3-pole main contacts + 1NEIN + 1NC auxiliary contacts
NennbetriebsspannungHauptstromkreis: Wechselstrom 50/60 Hz, up to 690V
Nennbetriebsstrom95A at AC-3, 400V; 132A at AC-1, 400V
Coil Voltage OptionsAC 24V/36V/110V/220V/380V, compatible with 50/60Hz
Coil Power ConsumptionPull-in power approx. 1800VA, holding power approx. 180VA
Bemessungsisolationsspannung800V (entspricht IEC 60947-4-1 Standard)
Rated Impulse Withstand Voltage8kV
Mechanisches LebenEtwa 10 Millionen Operationen
Elektrisches LebenEtwa 1 million operations at AC-3, 400V, 95A
Rated Operating FrequencyBis zu 1200 operations per hour (AC-3 utilization category)
Control Circuit VoltageCoil voltage range: 85%~110% of rated voltage
MontagemethodeDIN rail mounting (35mm standard rail) or screw fixing
VerkabelungsmethodeDouble-hole terminal blocks, main circuit applicable wire cross-section: 16~35mm²
Betriebstemperatur-5°C ~ +40°C (can reach +40°C when relative humidity ≤50%, derating required at higher humidity)
SchutzklasseIP20 (protects against finger contact and solid foreign objects with diameter ≥12mm)
WeightApproximately 1.2kg

III. Funktionsmerkmale

  1. High Compatibility Design: Same dimensions as Schneider LC1D series, directly interchangeable, compatible with various functional accessories
  2. High-efficiency Energy-saving Coil: Adopts high-quality electromagnetic materials, pull-in/holding power ratio up to 10:1, with significant energy-saving effect
  3. Multiple Protection Mechanisms:

Built-in overvoltage suppressor in the coil to extend coil service life

Main contacts made of silver alloy material, arc-resistant and anti-welding, improving reliability

Dust cover design, suitable for harsh industrial environments

  1. Flexible Wiring System: Double-hole terminal block design, more secure wiring, reducing loosening risk
  2. Wide Voltage Adaptability: Wide coil voltage range (85%~110%), adapting to power grid fluctuations
  3. Easy Installation: Standard-DIN-Schienenmontage, space-saving and convenient for quick replacement
  4. Application Scope

The CJX2-9511 contactor is suitable for the following industrial scenarios:

  1. Motorsteuerung:

Direct start/stop control of three-phase asynchronous motors (ca. 45kW at 380V)

Control of continuous operation equipment such as fans, water pumps and compressors

Control of frequent starting equipment such as conveyors and mixers

  1. Electrical Control Systems:

Remote switching on/off of circuits in power distribution systems

Control of electric heating equipment and lighting systems

Kombiniert mit thermischen Überlastrelais (z.B., NR2 series) to form electromagnetic starters for overload protection

  1. Industrielle Automatisierung:

Executive component of PLC control systems

Bypass contactor for soft starters and frequency converters

Electrical control of machine tools, printing machinery and packaging equipment

  1. Auswahlempfehlungen

5.1 Wichtige Auswahlpunkte

Selection FactorRecommended Considerations
LasttypSelect AC-3 rated current for motor loads; select AC-1 rated current for resistive loads
Power MatchingCan control ≤45kW three-phase asynchronous motors at 380V (AC-3)
SpulenspannungSelect according to control circuit power supply (220V/380V commonly used, 24V/36V/110V optional for special occasions)
Hilfskontakte1NO+1NC meets basic control needs; auxiliary contact modules can be added for more contacts
Operating FrequencyFor frequent operation (>600 times/hour), derating is recommended or special high-frequency contactors should be selected
UmgebungsbedingungenFor high-temperature, humid and dusty environments, derating or protection class upgrade should be considered

5.2 Alternative Modelle und Kompatibilität

Alternative ModelBrandDifference DescriptionCompatibility
NXC-9511Chint (Kunlun Series)Upgraded version of CJX2 series with improved performance and compatible dimensionsFully compatible, can be directly replaced
LC1D9511SchneiderOriginal design with consistent performanceInstallation and electrically compatible, interchangeable
TGC1-9511TengenSame specification product with more competitive priceInstallation compatible, consistent functions
CJX2-9501/9510ChintDifferent auxiliary contact configurations (01: 1NC; 10: 1NEIN)Consistent main circuit parameters, different auxiliary contacts

5.3 Recommended Supporting Products

  1. Thermisches Überlastrelais: NR2-93 (setting current 63~93A), directly pluggable with CJX2-9511 to form an electromagnetic starter
  2. Überlastschutz: Motor protectors (z.B., JD-5) can be optionally configured for more comprehensive protection
  3. Auxiliary Contact Expansion: Auxiliary contact modules such as F4-11 and F4-22 to increase the number of contacts
  4. Surge Suppression: RC snubber or varistor to protect coils and contacts
  5. Leitfaden zur Fehlerbehebung

6.1 Häufige Fehler und Lösungen

FehlerphänomenMögliche UrsachenTroubleshooting Steps
Contactor fails to pull in1. Coil not powered; 2. Low coil voltage; 3. Burned coil; 4. Mechanical jamming1. Check control circuit power supply and wiring; 2. Measure coil voltage (should be ≥85% of rated value); 3. Measure coil resistance with multimeter (normal value approx. several hundred ohms); 4. Check if iron core is jammed and remove foreign objects
Loud noise after pull-in1. Oil/dust on iron core end face; 2. Broken shading coil; 3. Low coil voltage1. Clean iron core end face; 2. Check shading coil (replace iron core if broken); 3. Adjust coil voltage to rated range
Contact overheating/ablation1. Overload operation; 2. Poor contact connection; 3. Arc suppression failure1. Check load current and replace with contactor of larger capacity; 2. Clean contacts and replace if severely ablated; 3. Check arc chute and ensure it is intact
Poor auxiliary contact connection1. Kontaktoxidation; 2. Spring fatigue; 3. Lose Verkabelung1. Clean contacts; 2. Replace auxiliary contact module; 3. Tighten wiring terminals
Durchbrennen der Spule1. Excessively high voltage; 2. Frequent starting; 3. Hohe Umgebungstemperatur1. Check power supply voltage and install overvoltage protection; 2. Reduce starting frequency or select high-frequency contactor; 3. Improve ventilation and lower ambient temperature

6.2 Contactor Status Judgment

Inspection ItemNormal StatusAbnormality Judgment
Coil ResistanceApprox. 300~800Ω (depending on coil voltage)Resistance of 0 (Kurzschluss) oder Unendlichkeit (offener Stromkreis) is abnormal
Main Contact Voltage Drop≤50mV when closedExcessively high voltage drop indicates poor contact connection
Iron Core Pull-inNo obvious noise and slight vibrationLoud noise and obvious vibration are abnormal
Arc ChuteIntact without carbonization marksSevere damage or carbonization requires replacement

VII. Installation and Maintenance Precautions

  1. Pre-installation Preparation:

Confirm that the model matches the load (aktuell, Stromspannung, auxiliary contacts)

Check for no external damage and complete accessories (arc chute, mounting bracket)

Select appropriate installation location (well-ventilated, von Wärmequellen und Vibrationsquellen fernhalten)

  1. Installationsspezifikationen:

Install after power cut, live operation is strictly prohibited

Standard-DIN-Schienenmontage (35mm), fix firmly

Main circuit wiring: wire cross-section 16~35mm², double-hole wiring to ensure firm connection

Control circuit wiring: wire cross-section 0.75~1.5mm², avoid laying in the same slot as main circuit

Installation direction: vertical installation (iron core upward), tilt ≤5°

  1. Wichtige Wartungspunkte:

Regular inspection (recommended once a month):

Contact status (presence of ablation and oxidation)

Coil temperature (should not exceed ambient temperature +40°C)

Wiring terminals (presence of loosening and overheating)

Arc chute (presence of damage and carbonization)

Reinigung: Remove dust with dry brush, solvent use is prohibited

Lubrication: Oil application is prohibited on iron core end face, keep clean and dry

Austauschzyklus:

Mechanical life: ca. 10 Millionen Operationen, replacement is recommended after reaching the limit

Electrical life: ca. 1 Millionen Operationen (AC-3), replacement cycle should be shortened for frequent starting

VIII. Zusammenfassung

The Chint CJX2-9511 contactor is an industrial-grade contactor with high cost performance and high compatibility. With its 95A rated current and 1NO+1NC auxiliary contact configuration, it is widely used in the control of three-phase motors below 45kW and electrical systems. During selection, comprehensive consideration should be given to factors such as load type, power and coil voltage. Installation and maintenance must strictly follow specifications to ensure safe and reliable operation. Compared with the Kunlun series NXC-9511, the CJX2-9511 has a more competitive price; compared with the Schneider LC1D9511, it has higher cost performance, making it an ideal choice in the field of industrial automation.