CHINT JYB-714 Flüssigkeitsstandrelais 3A AC220V - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

CHINT JYB-714 Flüssigkeitsstandrelais 3A AC220V - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Stromzähler/elektrisch/

CHINT JYB-714 Flüssigkeitsstandrelais 3A AC220V

Vollständiger Name: CHINT JYB-714 Series Liquid Level Relay (YB-714 is a simplified model) Key Specifications: Control voltage: AC220V 50Hz Contact rating: 3A AC220V (ohmsche Last) Kontaktkonfiguration: 1 changeover contact (NEIN + NC) Probe current: ≤ 50μA (safe low current) Control distance: ≤ 1km (length of probe cable) Betriebstemperatur: -5°C ~ +40°C Core Functions ...

  • Produktdetails

Vollständiger Name: CHINT JYB-714 Series Liquid Level Relay (YB-714 is a simplified model)

Key Specifications:

Control voltage: AC220V 50Hz

Contact rating: 3A AC220V (ohmsche Last)

Kontaktkonfiguration: 1 changeover contact (NEIN + NC)

Probe current: ≤ 50μA (safe low current)

Control distance: ≤ 1km (length of probe cable)

Betriebstemperatur: -5°C ~ +40°C

  1. Kernfunktionen & Anwendungen

Funktion: Detects water level via electrodes, automatically controls pump start/stop, supporting water supply / drainage modes.

Typische Anwendungen:

Civil water towers, elevated tanks, underground cisterns

Industrial circulating water systems, small sewage treatment equipment

Not suitable for: Oil, pure water (low conductivity), flammable and explosive liquids

  1. Funktionsprinzip (Electrode Detection)
  2. Water Supply Mode: When water level is below the low limit, electrodes 5-6 conduct, relay energizes, pump starts. When water rises to high limit, electrodes 6-7 conduct, relay de-energizes, pump stops.
  3. Drainage Mode: When water level exceeds high limit, electrodes 6-7 conduct, relay energizes, pump starts. When water drops to low limit, electrodes 5-6 disconnect, relay de-energizes, pump stops.
  4. Terminal Definition (Standard 8‑pin Base)
Terminal No.FunktionWiring Description
1Power Line LConnect to AC220V Live wire
2Normalerweise geschlossen (NC)Commonly used for drainage mode
3Common (COM)Common terminal of contacts
4Normalerweise geöffnet (NEIN)Commonly used for water supply mode
5Power Neutral NConnect to AC220V Neutral wire
6Middle Level ElectrodeMain detection electrode
7High Level ElectrodeUpper limit stop detection
8Low Level ElectrodeLower limit start detection
  1. Typical Wiring (Single‑phase Water Pump)
  2. Water Supply Control:

Terminal 1 to L, Terminal 5 to N

Terminal 6 to middle level, 7 to high level, 8 to low level

Terminal 4 (NEIN) + Terminal 3 (COM) connect to contactor coil control

  1. Drainage Control:

Terminal 1 to L, Terminal 5 to N

Terminal 6 to middle level, 7 to high level, 8 to low level

Terminal 2 (NC) + Terminal 3 (COM) connect to contactor coil control

  1. Installation & Nutzungshinweise
  2. Electrode Installation:

Electrode material: 304 stainless steel recommended for corrosion resistance

Spacing: ≥ 10cm between high/low electrodes; ≥ 15cm between electrodes and tank wall

Avoid installation in bubble‑prone areas

  1. Electrical Safety:

Route signal cables separately, keep ≥ 30cm from power cables

Must be protected by a 10A circuit breaker

Use waterproof junction boxes in damp environments

  1. Daily Maintenance:

Clean scale and dirt from electrodes regularly to maintain conductivity

Inspect probe cable insulation for damage

  1. Häufige Fehler & Fehlerbehebung
Fault SymptomMögliche UrsacheLösung
No operation at allPoor power connection / incorrect voltageMeasure AC220V between terminals 1 Und 5
Fails to detect water levelBroken probe wire / electrode foulingVerkabelung prüfen, clean electrodes
Malfunction / false triggeringExcessively high sensitivity / shorted electrodesAdjust electrode spacing, check insulation
Contact welding / stickingÜberlast / contact agingReplace relay; install freewheeling diode across contactor coil
  1. Auswahl & Alternativen

Upgraded Model: JYB-714B (with LED indicator for clearer status)

Alternative Brands: Xinling HHY7G/HHY7P, People Electrical Appliance JYB series (parameter‑compatible)

Notiz: For high‑power pumps, must use an AC contactor; do not drive directly (limited 3A contact capacity)

Recommended Replacements for CHINT JYB-714 (YB-714) 3A AC220V Liquid Level Relay

  1. CHINT Original Upgraded Alternatives
ModellKey ImprovementsAnwendung
JYB-714B AC220VAdded LED operating status indicator for clear visualizationAll basic level control requiring status indication
JYB-714C AC220VDual LED indicators (supply/drain), enhanced anti-interferenceIndustrial environments with frequent mode switching

Matching Core Parameters: All retain 3A AC220V contact rating, 1 changeover contact, electrode detection, fully compatible with original base and wiring.

  1. Direct Domestic Brand Alternatives (100% Parameter Compatible)
  2. Delixi Series

JYB-714 AC220V (Standardtyp)

JYB-714A AC220V (improved, stronger anti-interference)

Merkmale: Same platform design as CHINT, universal 8‑pin base, lower price, wide service network.

  1. Xinling Electric Series

HHY7G AC220V (water supply dedicated)

HHY7P AC220V (drainage dedicated)

Merkmale: 3A AC220V contact rating, control distance up to 100m, suitable for long probe cables.

  1. People Electrical Appliance Series

JYB-714 AC220V liquid level relay

Merkmale: Compliant with GB/T14048.5, excellent moisture resistance, ideal for humid environments.

  1. Specialized Alternatives (Upgraded Functions / Besondere Umgebungen)
  2. CKC (Taiwan)

C61F-GP-N AC220V non-float liquid level relay

Vorteile: Imported quality, strong anti-interference, suitable for precision control, supports 3A AC220V load.

  1. OMRON

61F-GP AC220V liquid level control relay

Vorteile: Internationally renowned, high reliability, LED status indication, Geeignet für kritische Geräte.

Notiz: Requires dedicated base, higher cost.

  1. Kabellos / Smart Alternative

CHINT NB-IoT Intelligent Liquid Level Controller: Fernüberwachung, mobile APP control, suitable for unattended sites.

Merkmale: No wiring needed, data transmission via NB-IoT, supports water level alarms and history query.

  1. Key Compatibility Requirements for Replacement
Key ParameterMuss übereinstimmenNotizen
Kontaktbewertung3A AC220V (ohmsche Last)Direct for small loads; contactor required for high power
Kontaktkonfiguration1 changeover contact (NEIN + NC)Ensures both supply and drainage modes
BetriebsspannungAC220V 50HzMatches original power supply
Mounting BaseStandard 8‑pin baseDirect replacement without re-drilling
Detection MethodElectrode type (≤50μA safe current)Compatible with existing probe cables
  1. Recommendation Priority
  2. Erste Wahl: CHINT JYB-714B/C → Original upgrade, fully compatible, clear indication
  3. Best Value: Delixi JYB-714A → Affordable, stable, convenient service
  4. Industrial Use: Xinling HHY7G/7P → Long distance, strong anti-interference
  5. Critical Equipment: OMRON 61F-GP → High reliability for continuous operation

Complete Model List of CHINT Liquid Level Relays

CHINT liquid level relays are available in three main series: JYB-714 (basic type), NJYW1 (industrial enhanced type), and NJB1-YW (modularer Typ). Below is the complete model list by series.

  1. JYB-714 Series (Core Basic Series)

1.1 Standard Models

ModellControl VoltageHauptmerkmaleSample Order No.
JYB-714 AC36VAC36V 50HzBasisversion, no indicator710039910301036
JYB-714 AC220VAC220V 50HzBasisversion, no indicator710039910301037
JYB-714 AC380VAC380V 50HzBasisversion, no indicator710039910301038

1.2 Upgraded Models (with LED Indicator)

ModellControl VoltageHauptmerkmaleSample Order No.
JYB-714B AC36VAC36V 50HzSingle LED operation indicator710039910301378
JYB-714B AC220VAC220V 50HzSingle LED operation indicator710039910301379
JYB-714B AC380VAC380V 50HzSingle LED operation indicator710039910301380
JYB-714C AC220VAC220V 50HzDual LED (supply/drain), enhanced anti-interference710039910401379
JYB-714C AC380VAC380V 50HzDual LED (supply/drain), enhanced anti-interference710039910401380

Common Parameters:

Contact rating: 3A AC220V (ohmsche Last)

Kontaktkonfiguration: 1 changeover contact (NEIN + NC)

Probe current: ≤ 50μA

Control distance: ≤ 1km

Montage: Standard 8‑pin base (Universal-)

  1. NJYW1 Series (Industrial Enhanced Series)
ModellControl VoltageHauptmerkmaleAnwendung
NJYW1-NL1 AC220VAC220V 50HzStandard, moisture-resistantCivil / light industrial water towers
NJYW1-NL1 AC380VAC380V 50HzStandard, moisture-resistantIndustrial water tanks
NJYW1-NL2 AC220VAC220V 50HzLong distance (≤2km)Large water conservancy
NJYW1-NL2 AC380VAC380V 50HzLong distance (≤2km)Sewage treatment plants
NJYW1-BL1 AC220VAC220V 50HzExplosion‑proofChemical industry, underground pump rooms
NJYW1-BL1 AC380VAC380V 50HzExplosion‑proofPetrochemical tank farms
NJYW1-BL2 AC220VAC220V 50HzExplosion‑proof + long distanceOffshore platforms, mine drainage
NJYW1-BL2 AC380VAC380V 50HzExplosion‑proof + long distanceTunnel drainage systems

Series Advantages: Protection class IP40, improved anti-interference, stable probe current ≤40μA.

  1. NJB1-YW Series (Modular Series)
ModellControl VoltageMontageAnwendung
NJB1-YW AC220VAC220V 50HzDIN rail mountingAutomation control panels
NJB1-YW AC380VAC380V 50HzDIN rail mountingIndustrial automation systems
NJB1-YW DC24VDC24VDIN rail mountingDC control systems, PLC integration

Merkmale:

DIN rail mounting (35mm-Standard) for automation integration

Fault diagnosis, PLC compatible

Contact rating increased to 5A AC220V, suitable for direct small pump control

  1. Model Naming Explanation
  2. JYB-714 Series: JYB (liquid level relay)-714 (design code)-[A/B/C] (version: A=basic, B=single LED, C=dual LED)-Stromspannung
  3. NJYW1 Series: N (CHINT) JYW (liquid level relay) 1 (Code)-[NL/BL] (NL=standard, BL=explosion‑proof)-[1/2] (distance: 1=1km, 2=2km)-Stromspannung
  4. NJB1-YW Series: N (CHINT) JB (modular) 1 (Code)-YW (liquid level control)-Stromspannung
  5. Selection Parameter Comparison
ParameterJYB-714 SeriesNJYW1 SeriesNJB1-YW Series
Kontaktbewertung3A AC220V3A AC220V5A AC220V
Control Distance≤1km≤1–2km≤1km
Montage8‑pin base8‑pin base / Schiene35mm DIN-Schiene
IndicatorOptional (B/C type)StandardStandard
Anti-interferenceBasicIndustriellIndustriell
UmfeldCivil / light industryIndustriell / feuchtAutomation systems

Vorher:

Nächste:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen