The Chint NXB63-3P-D63 circuit breaker is a three-phase miniature circuit breaker (MCB) designed for high-load scenarios. It is suitable for circuits with an alternating current of 50/60Hz and a rated voltage of 400V AC, providing overload, Kurzschlussschutz, and isolation functions. Below is an analysis of its core information: Core Parameters and FunctionsChint NXC-75/220V AC ...

  • Produktdetails

The Chint NXB63-3P-D63 Leistungsschalter is a three-phase miniature circuit breaker (MCB) designed for high-load scenarios. It is suitable for circuits with an alternating current of 50/60Hz and a rated voltage of 400V AC, providing overload, Kurzschlussschutz, and isolation functions. Below is an analysis of its core information:

  1. Kernparameter und FunktionenChint NXC-75/220V AC-Schütz
  2. Specification FeaturesChint DC-Schütz NC1-5011-36V

Poles: 3P (three-phase), suitable for three-phase four-wire power distribution systems.

Nennstrom: 63A, matching the continuous operation requirements of high-power equipment (z.B., Motoren, Transformatoren).

Trip Characteristic: Type D curve, with an instantaneous trip current of 10–16 times the rated current, effectively handling inrush currents during motor starting.

Bruchkapazität: 6Die, safely interrupting short-circuit fault currents to prevent contact welding or equipment damage.

  1. Technical Standards

Complies with IEC 60898-1 (international) und GB/T 10963.1 (China) Standards, and is 3C certified.

– Betriebstemperaturbereich: -35°C to 70°C, adapting to temperature fluctuations in industrial environments.

  1. Anwendungsszenarien

Industrial Sector: Motor control, power distribution for production line equipment. The Type D trip characteristic avoids frequent false tripping.

Commercial and Residential Use: Main switches or branch protection in three-phase power supply systems, such as power distribution in shopping malls and factories.

Besondere Szenarien: Equipment requiring high short-circuit protection (z.B., welding machines, Transformatoren), enabling rapid response to fault currents.

III. Installation and Usage Recommendations

  1. Installationsanforderungen

– Muss von einem professionellen Elektriker installiert werden, vertically mounted on a standard 35mm rail, ensuring wiring screws are tightened to prevent loosening and heat generation.

Use wires with appropriate cross-sectional area (z.B., 6mm² copper wire) and reserve sufficient operating space during wiring.

  1. Maintenance and Precautions

Regularly inspect contacts and terminal blocks to avoid poor contact due to oxidation or looseness.

If tripping occurs frequently, check whether the load exceeds the rated current or if a short-circuit fault exists.

  1. Price and Market Positioning

Reference Price: More cost-effective than similar imported brands (z.B., Siemens EA9 series).

Positioning: As an upgraded version of the DZ47 series, the NXB-63 improves breaking capacity and reliability, suitable for cost-sensitive scenarios requiring high protection performance.

  1. Comparison with Siemens Equivalent Products

Bruchkapazität: The Siemens EA9AN3C63 has a breaking capacity of 6kA, comparable to the NXB-63, but its price is typically 30–50% higher.

Trip Characteristics: Siemens Type D curve products (z.B., 5SJ6 series) have an instantaneous trip multiple of 10–14 times, close to the NXB-63’s 10–16 times, both suitable for motor protection.

Certifications: Siemens products are usually UL-certified, while the NXB-63 does not explicitly mention North American certifications. U.S. users are advised to prioritize models with UL marks.

  1. Vorsichtsmaßnahmen

Spannungsanpassung: The 3P model has a rated voltage of 400V AC and cannot be used in single-phase 230V circuits.

Zertifizierungskonformität: For use in the U.S., verify whether the product is UL-certified or choose other models compliant with North American standards (z.B., Siemens 5SJ6 series).

Technical Parameters of Chint NXB63-3P-D63 Circuit Breaker

(Compiled from official data and industry standards)

  1. Core Electrical Parameters
  2. Nennspannung: AC 400V (three-phase system), suitable for 380V/400V power distribution scenarios; not for single-phase 230V circuits.
  3. Nennstrom: 63A, matching continuous operation of high-power equipment (z.B., Motoren, Transformatoren).
  4. Trip Characteristic: Type D curve, instantaneous trip current 10–16× rated current, effectively handling motor starting inrush currents.
  5. Bruchkapazität: 6Die (compliant with IEC 60898-1), safely interrupting short-circuit fault currents.
  6. Mechanical and Environmental Parameters
  7. Poles: 3P (three-phase), suitable for three-phase four-wire power distribution systems.
  8. Mechanisches Leben: 20,000 Operationen; Elektrisches Leben: 10,000 Operationen, ensuring long-term stable operation.
  9. Betriebstemperatur: -35°C bis +70°C, adapting to industrial temperature fluctuations.
  10. Installationsmethode: Standardmäßige 35-mm-Schienenmontage, requiring vertical fixation for heat dissipation and operational stability.

III. Zertifizierungen und Compliance

  1. Inländische Zertifizierung: 3C certified (Certificate No. 2020980307001645), compliant with GB/T 10963.1.
  2. Internationale Standards: Compliant with IEC 60898-1, but not explicitly UL-certified. North American users should prioritize models with UL marks (z.B., Siemens 5SJ6 series).
  3. Accessories and Extended Functions
  4. Auxiliary Contacts: Supports accessories like AX-X1 (1NO+1NC), MX+OF (shunt trip + Hilfskontakt) for remote control and status feedback.
  5. Wiring Terminals: Threaded pressure plate terminals recommended for 6mm² copper wire (for 63A load), with a tightening torque of 2.0N·m to avoid heat generation.
  6. Dimensions and Installation Size

Abmessungen: Approximately 90mm (W) × 75mm (H) × 85mm (D), subject to the official manual.

Wiring Space: Reserve sufficient space; recommended wire cross-sectional area: 1–25mm² (selected by load current).

  1. Notizen
  2. Spannungsanpassung: Only for 400V three-phase systems; not for single-phase 230V circuits.
  3. Überlastschutz: Frequent tripping indicates checking whether the load exceeds the rated current or a short circuit exists.
  4. North American Market: Not UL-certified; recommend Siemens 5SJ6 or other North American-compliant models.

For complete technical manuals or customized parameters, visit Chint Electric’s official website or contact a supplier. For North American applications, ensure product compliance to avoid safety risks.