CHINT YBLX-K1/511 (often miswritten as YBLX-K1511) is a universal self-resetting limit switch belonging to the YBLX-K1 series. It is widely used for overtravel protection and position control in industrial automation and machine tools.
- Kernparameter & Struktur
| Artikel | Spezifikation |
| Vollständiges Modell | YBLX‑K1/511 (JLXK1/511) |
| Actuator Type | Universal type (Code “5”) |
| Kontaktkonfiguration | 1 NEIN + 1 NC |
| Nennspannung | Wechselstrom 380 V, Gleichstrom 220 V |
| Nennstrom | AC‑15 0.8 A, DC‑13 0.15 A |
| Schutzgrad | IP52 |
| Standards | GB/T14048.5, IEC60947‑5‑1 |
| Verkabelungskapazität | 1×(0.5–1) mm² cable, stripping length 7–9 mm |
| Fastening Screw | M3.5, Anzugsdrehmoment 0.8 N·m |
| Betriebsfrequenz | Mechanisch: 1200 Operationen/Stunde; Elektrisch: 600 Operationen/Stunde |
| Lebensdauer | Mechanical ≥ 1,000,000 Zyklen; Electrical ≥ 100,000 Zyklen |
- Model Meaning Explanation
Meaning of each part in YBLX-K1/511:
YBLX: General code for limit switch
Q1: Quick-action series
/5: Actuator is universal type (actuated from any direction)
/11: Contact combination 1 NEIN + 1 NC
- Main Features & Vorteile
- Universal actuation design: Actuator senses in 360° directions, suitable for complex installations
- Self-resetting: Automatically returns to original position after actuation, no manual reset needed
- Silver-alloy contacts: Excellent conductivity, arc resistance, wear resistance, lange lebensdauer
- IP52 protection: Dust-proof and moisture-proof for industrial environments
- Flexible installation: Supports multiple mounting methods for various layouts
- Safe and reliable: Complies with international standards, short-circuit withstand up to 1000 A
- Anwendungen
- Werkzeugmaschinen: Table travel limit, automatic reciprocating control
- Automatisierte Produktionslinien: Material positioning, lifting mechanism limit protection
- Lifting machinery: Limit protection, anti-collision control
- Verpackungsmaschinen: Positionierung, counting control
- Textilmaschinen: Yarn tension control, mechanical limit
- Other industrial equipment: Motion control, direction/speed change control
- Installation & Wiring Guide
Installationsschritte
- Select proper mounting position to ensure reliable actuation of the actuator
- Secure the switch with M4 screws, tightening torque 0.8–1.2 N·m
- Connect wires:
NO contact: “turn on at position” in control circuit
NC contact: “turn off at position” (commonly used for emergency stop)
- Check actuation direction and reset for sensitive and reliable operation
- Power on and test to confirm normal circuit function
Wiring Notes
Cable stripping length: 7–9 mm; avoid too short or too long exposed conductor
Tighten terminals securely to prevent loose connections
Distinguish AC/DC circuits; do not exceed rated voltage/current
Avoid direct control of high-power loads; use an intermediate relay if needed
- Betrieb & Wartung
- Regularly check actuator flexibility and reset performance
- Clean contact area to remove dust and oil, preventing poor contact
- Inspect wire connections for looseness caused by vibration
- Avoid overtravel and overfrequency operation to protect internal mechanism
- Replace the switch promptly if contact burning, sluggish action, usw. occur
- Ersatz & Auswahlreferenz
Other common models in YBLX-K1 series:
YBLX-K1/111: Single roller lever type, 1 NEIN + 1 NC
YBLX-K1/211: Double roller lever type, 1 NEIN + 1 NC
YBLX-K1/311: Plunger type, 1 NEIN + 1 NC
YBLX-K1/411: Roller plunger type, 1 NEIN + 1 NC
- Einkauf & Warranty Information
Official Order No.: 7101125000000511
CHINT Limit Switch Series List & Cross-Brand Model Cross-Reference
- Complete CHINT Limit Switch Series List
| Serie | Merkmale | Typische Anwendungen | Representative Models |
| YBLX‑K1 / JLXK1 | Quick‑action, multiple actuators, self‑resetting | Werkzeugmaschinen, automation | YBLX‑K1/111, YBLX‑K1/511 |
| YBLX‑ME / 8000 | General purpose, compatible with Schneider XCE mounting | General machinery, Montagelinien | YBLX‑ME/8108, YBLX‑ME/8101 |
| YBLX‑19 | Roller lever type, various lever configurations | Machine tables, lifting mechanisms | YBLX‑19‑111, YBLX‑19‑222 |
| YBLX‑WL | Watertight, IP65 | Outdoor equipment, wet environments | YBLX‑WL/CA120, YBLX‑WL/CA220 |
| YBLX‑P1 | Plunger type, short stroke, high frequency | Stamping equipment, counters | YBLX‑P1/303, YBLX‑P1/120 |
| YBLX‑10 | Heavy‑duty, high current, metal housing | Kräne, Metallurgie | YBLX‑10/11, YBLX‑10/21 |
| YBLX‑JW2 | Micro, short stroke, high sensitivity | Precision machinery, instruments | YBLX‑JW2/11Z/3, YBLX‑JW2/22Z |
| YBLX‑33 / 44 | Heavy‑duty, high operating force, robust | Hafenmaschinen, Bergbau | YBLX‑33/11, YBLX‑44/22 |
| YBLX‑X2 | Kompakt, miniaturized | Kleine Ausrüstung, medical devices | YBLX‑X2/11G, YBLX‑X2/22D |
| NKX2 / NKX3 | Modern design, modular mounting | Smart factories, automation lines | NKX2‑11Z, NKX3‑22Z |
| YBLXW‑6 | Microswitch, small size, high sensitivity | Electronics, home appliances | YBLXW‑6/11DL, YBLXW‑6/22CL |
| YBLX‑HL | High temperature resistant, ‑25 ~ +120 °C | Metallurgie, drying equipment | YBLX‑HL/11, YBLX‑HL/22 |
| YBLX‑3 / LX3 | Metal housing, protected design | Heavy machinery, explosion‑proof areas | YBLX‑3/11H, YBLX‑3/22J |
- Cross-Brand Model Cross-Reference (Major Brands)
2.1 CHINT vs Schneider (Most Common Replacement)
| CHINT Model | Equivalent Schneider | Notizen |
| YBLX‑K1/511 | XCE145 | Universal actuator, 1 NEIN + 1 NC, compatible mounting |
| YBLX‑ME/8108 | XCE102 | Roller lever, self‑resetting, matching electrical ratings |
| YBLX‑ME/8101 | XCE101 | Plunger type, quick action, same mounting holes |
| YBLX‑K1/111 | XCE118 | Single roller lever, 1 NEIN + 1 NC, similar operating force |
| YBLX‑19‑111 | XCE110 | Straight lever inner actuation, same mounting space |
| YBLX‑WL/CA120 | XCKD2120P16 | Watertight, 2 NEIN + 2 NC, IP65 |
2.2 CHINT vs Siemens
| CHINT Model | Equivalent Siemens | Notizen |
| YBLX‑K1/511 | 3SE5 112‑0CH01 | Universal, 1 NEIN + 1 NC, mechanical life ≥ 1M cycles |
| YBLX‑ME/8108 | 3SE5 100‑0CH02 | Roller lever, self‑resetting, compatible mounting |
| YBLX‑19‑222 | 3SE5 122‑0CH01 | Forked double roller lever, bidirectional limit |
| YBLX‑P1/303 | 3SE5 212‑0CH01 | Long plunger, short stroke, high frequency |
| YBLX‑WL/CA220 | 3SE5 232‑0CH01 | Watertight, 3 NEIN + 3 NC, outdoor use |
2.3 CHINT vs ABB
| CHINT Model | Equivalent ABB | Notizen |
| YBLX‑K1/111 | LS31K01 | Single roller lever, 1 NEIN + 1 NC, matching ratings |
| YBLX‑ME/8108 | LS31K10 | Roller lever, self‑resetting, same mounting position |
| YBLX‑19‑131 | LS31K20 | Straight lever groove actuation, consistent precision |
| YBLX‑P1/120 | LS31K30 | Short plunger, quick action, similar response |
2.4 CHINT vs Omron
| CHINT Model | Equivalent Omron | Notizen |
| YBLX‑K1/511 | D4V‑8108SZ | Universal, 1 NEIN + 1 NC, operating force 0.5–1.5 N |
| YBLX‑ME/8108 | D4V‑8166Z | Roller lever, self‑resetting, mechanical life ≥ 1M cycles |
| YBLX‑WL/CA120 | D4V‑8122Z | Watertight, 2 NEIN + 2 NC, IP65 |
| YBLXW‑6/11DL | D4V‑2120Z | Microswitch, short roller lever, 1 NEIN + 1 NC |
- Key Points for Replacement & Auswahl
- Mounting compatibility: Prefer models with identical mounting dimensions (z.B., YBLX-ME ↔ XCE) for direct replacement
- Electrical matching:
Nennspannung: Wechselstrom 380 V / Gleichstrom 220 V
Nennstrom: AC-15 0.8 A, DC-13 0.15 A
Kontakte: 1 NEIN + 1 NC (Standard), 2 NEIN + 2 NC (special)
- Actuator type matching:
| Actuator Type | CHINT Code | International Equivalent |
| Universal | 5 | XCE145, 3SE5 112 Serie |
| Single roller lever | 1 | XCE118, 3SE5 100 Serie |
| Double roller lever | 2 | XCE110, 3SE5 122 Serie |
| Plunger | 3 | XCE101, 3SE5 101 Serie |
| Roller plunger | 4 | XCE103, 3SE5 103 Serie |
- Protection level selection:
General environment: IP52 (YBLX-K1)
Humid environment: IP65 (YBLX-WL)
Outdoor use: IP67 (custom models)
- Auswahl & Replacement Recommendations
- Prefer direct series replacement: YBLX-ME ↔ XCE, YBLX-K1 ↔ 3SE5 are most reliable
- Contact count: Ensure NO/NC quantity matches to avoid logic errors
- Mechanical parameters: Match operating force, travel, reset speed to prevent misoperation
- Special environment adaptation:
Im Freien / wet: YBLX-WL (IP65)
Hohe Temperatur: YBLX-HL (-25 ~ +120 °C)
Explosion-proof: YBLX-3 (metal housing, zertifiziert)
Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien






















NH42-63-318x560.png)