CHINT YBLX-K1/511 Limit Switch

CHINT YBLX-K1/511 (often miswritten as YBLX-K1511) is a universal self-resetting limit switch belonging to the YBLX-K1 series. It is widely used for overtravel protection and position control in industrial automation and machine tools. Kernparameter & Structure Item Specification Full Model YBLX‑K1/511 (JLXK1/511) Actuator Type Universal type (Code “5”) Kontaktkonfiguration 1 NEIN + 1 ...

  • Produktdetails

CHINT YBLX-K1/511 (often miswritten as YBLX-K1511) is a universal self-resetting limit switch belonging to the YBLX-K1 series. It is widely used for overtravel protection and position control in industrial automation and machine tools.

  1. Kernparameter & Struktur
ArtikelSpezifikation
Vollständiges ModellYBLX‑K1/511 (JLXK1/511)
Actuator TypeUniversal type (Code “5”)
Kontaktkonfiguration1 NEIN + 1 NC
NennspannungWechselstrom 380 V, Gleichstrom 220 V
NennstromAC‑15 0.8 A, DC‑13 0.15 A
SchutzgradIP52
StandardsGB/T14048.5, IEC60947‑5‑1
Verkabelungskapazität1×(0.5–1) mm² cable, stripping length 7–9 mm
Fastening ScrewM3.5, Anzugsdrehmoment 0.8 N·m
BetriebsfrequenzMechanisch: 1200 Operationen/Stunde; Elektrisch: 600 Operationen/Stunde
LebensdauerMechanical ≥ 1,000,000 Zyklen; Electrical ≥ 100,000 Zyklen
  1. Model Meaning Explanation

Meaning of each part in YBLX-K1/511:

YBLX: General code for limit switch

Q1: Quick-action series

/5: Actuator is universal type (actuated from any direction)

/11: Contact combination 1 NEIN + 1 NC

  1. Main Features & Vorteile
  2. Universal actuation design: Actuator senses in 360° directions, suitable for complex installations
  3. Self-resetting: Automatically returns to original position after actuation, no manual reset needed
  4. Silver-alloy contacts: Excellent conductivity, arc resistance, wear resistance, lange lebensdauer
  5. IP52 protection: Dust-proof and moisture-proof for industrial environments
  6. Flexible installation: Supports multiple mounting methods for various layouts
  7. Safe and reliable: Complies with international standards, short-circuit withstand up to 1000 A
  8. Anwendungen
  9. Werkzeugmaschinen: Table travel limit, automatic reciprocating control
  10. Automatisierte Produktionslinien: Material positioning, lifting mechanism limit protection
  11. Lifting machinery: Limit protection, anti-collision control
  12. Verpackungsmaschinen: Positionierung, counting control
  13. Textilmaschinen: Yarn tension control, mechanical limit
  14. Other industrial equipment: Motion control, direction/speed change control
  15. Installation & Wiring Guide

Installationsschritte

  1. Select proper mounting position to ensure reliable actuation of the actuator
  2. Secure the switch with M4 screws, tightening torque 0.8–1.2 N·m
  3. Connect wires:

NO contact: “turn on at positionin control circuit

NC contact: “turn off at position” (commonly used for emergency stop)

  1. Check actuation direction and reset for sensitive and reliable operation
  2. Power on and test to confirm normal circuit function

Wiring Notes

Cable stripping length: 7–9 mm; avoid too short or too long exposed conductor

Tighten terminals securely to prevent loose connections

Distinguish AC/DC circuits; do not exceed rated voltage/current

Avoid direct control of high-power loads; use an intermediate relay if needed

  1. Betrieb & Wartung
  2. Regularly check actuator flexibility and reset performance
  3. Clean contact area to remove dust and oil, preventing poor contact
  4. Inspect wire connections for looseness caused by vibration
  5. Avoid overtravel and overfrequency operation to protect internal mechanism
  6. Replace the switch promptly if contact burning, sluggish action, usw. occur
  7. Ersatz & Auswahlreferenz

Other common models in YBLX-K1 series:

YBLX-K1/111: Single roller lever type, 1 NEIN + 1 NC

YBLX-K1/211: Double roller lever type, 1 NEIN + 1 NC

YBLX-K1/311: Plunger type, 1 NEIN + 1 NC

YBLX-K1/411: Roller plunger type, 1 NEIN + 1 NC

  1. Einkauf & Warranty Information

Official Order No.: 7101125000000511

CHINT Limit Switch Series List & Cross-Brand Model Cross-Reference

  1. Complete CHINT Limit Switch Series List
SerieMerkmaleTypische AnwendungenRepresentative Models
YBLX‑K1 / JLXK1Quick‑action, multiple actuators, self‑resettingWerkzeugmaschinen, automationYBLX‑K1/111, YBLX‑K1/511
YBLX‑ME / 8000General purpose, compatible with Schneider XCE mountingGeneral machinery, MontagelinienYBLX‑ME/8108, YBLX‑ME/8101
YBLX‑19Roller lever type, various lever configurationsMachine tables, lifting mechanismsYBLX‑19‑111, YBLX‑19‑222
YBLX‑WLWatertight, IP65Outdoor equipment, wet environmentsYBLX‑WL/CA120, YBLX‑WL/CA220
YBLX‑P1Plunger type, short stroke, high frequencyStamping equipment, countersYBLX‑P1/303, YBLX‑P1/120
YBLX‑10Heavy‑duty, high current, metal housingKräne, MetallurgieYBLX‑10/11, YBLX‑10/21
YBLX‑JW2Micro, short stroke, high sensitivityPrecision machinery, instrumentsYBLX‑JW2/11Z/3, YBLX‑JW2/22Z
YBLX‑33 / 44Heavy‑duty, high operating force, robustHafenmaschinen, BergbauYBLX‑33/11, YBLX‑44/22
YBLX‑X2Kompakt, miniaturizedKleine Ausrüstung, medical devicesYBLX‑X2/11G, YBLX‑X2/22D
NKX2 / NKX3Modern design, modular mountingSmart factories, automation linesNKX2‑11Z, NKX3‑22Z
YBLXW‑6Microswitch, small size, high sensitivityElectronics, home appliancesYBLXW‑6/11DL, YBLXW‑6/22CL
YBLX‑HLHigh temperature resistant, ‑25 ~ +120 °CMetallurgie, drying equipmentYBLX‑HL/11, YBLX‑HL/22
YBLX‑3 / LX3Metal housing, protected designHeavy machinery, explosion‑proof areasYBLX‑3/11H, YBLX‑3/22J
  1. Cross-Brand Model Cross-Reference (Major Brands)

2.1 CHINT vs Schneider (Most Common Replacement)

CHINT ModelEquivalent SchneiderNotizen
YBLX‑K1/511XCE145Universal actuator, 1 NEIN + 1 NC, compatible mounting
YBLX‑ME/8108XCE102Roller lever, self‑resetting, matching electrical ratings
YBLX‑ME/8101XCE101Plunger type, quick action, same mounting holes
YBLX‑K1/111XCE118Single roller lever, 1 NEIN + 1 NC, similar operating force
YBLX‑19‑111XCE110Straight lever inner actuation, same mounting space
YBLX‑WL/CA120XCKD2120P16Watertight, 2 NEIN + 2 NC, IP65

2.2 CHINT vs Siemens

CHINT ModelEquivalent SiemensNotizen
YBLX‑K1/5113SE5 112‑0CH01Universal, 1 NEIN + 1 NC, mechanical life ≥ 1M cycles
YBLX‑ME/81083SE5 100‑0CH02Roller lever, self‑resetting, compatible mounting
YBLX‑19‑2223SE5 122‑0CH01Forked double roller lever, bidirectional limit
YBLX‑P1/3033SE5 212‑0CH01Long plunger, short stroke, high frequency
YBLX‑WL/CA2203SE5 232‑0CH01Watertight, 3 NEIN + 3 NC, outdoor use

2.3 CHINT vs ABB

CHINT ModelEquivalent ABBNotizen
YBLX‑K1/111LS31K01Single roller lever, 1 NEIN + 1 NC, matching ratings
YBLX‑ME/8108LS31K10Roller lever, self‑resetting, same mounting position
YBLX‑19‑131LS31K20Straight lever groove actuation, consistent precision
YBLX‑P1/120LS31K30Short plunger, quick action, similar response

2.4 CHINT vs Omron

CHINT ModelEquivalent OmronNotizen
YBLX‑K1/511D4V‑8108SZUniversal, 1 NEIN + 1 NC, operating force 0.5–1.5 N
YBLX‑ME/8108D4V‑8166ZRoller lever, self‑resetting, mechanical life ≥ 1M cycles
YBLX‑WL/CA120D4V‑8122ZWatertight, 2 NEIN + 2 NC, IP65
YBLXW‑6/11DLD4V‑2120ZMicroswitch, short roller lever, 1 NEIN + 1 NC
  1. Key Points for Replacement & Auswahl
  2. Mounting compatibility: Prefer models with identical mounting dimensions (z.B., YBLX-ME ↔ XCE) for direct replacement
  3. Electrical matching:

Nennspannung: Wechselstrom 380 V / Gleichstrom 220 V

Nennstrom: AC-15 0.8 A, DC-13 0.15 A

Kontakte: 1 NEIN + 1 NC (Standard), 2 NEIN + 2 NC (special)

  1. Actuator type matching:
Actuator TypeCHINT CodeInternational Equivalent
Universal5XCE145, 3SE5 112 Serie
Single roller lever1XCE118, 3SE5 100 Serie
Double roller lever2XCE110, 3SE5 122 Serie
Plunger3XCE101, 3SE5 101 Serie
Roller plunger4XCE103, 3SE5 103 Serie
  1. Protection level selection:

General environment: IP52 (YBLX-K1)

Humid environment: IP65 (YBLX-WL)

Outdoor use: IP67 (custom models)

  1. Auswahl & Replacement Recommendations
  2. Prefer direct series replacement: YBLX-ME ↔ XCE, YBLX-K1 ↔ 3SE5 are most reliable
  3. Contact count: Ensure NO/NC quantity matches to avoid logic errors
  4. Mechanical parameters: Match operating force, travel, reset speed to prevent misoperation
  5. Special environment adaptation:

Im Freien / wet: YBLX-WL (IP65)

Hohe Temperatur: YBLX-HL (-25 ~ +120 °C)

Explosion-proof: YBLX-3 (metal housing, zertifiziert)

Vorher:

Nächste: