CJX2-4011 is a 3-pole AC contactor from CHNT’s classic CJX2 series, with a 40A rated current and equipped with 1 NEIN + 1 NC auxiliary contacts.
It is suitable for AC-3 duty (z.B., Drehstrommotoren) and widely used in industrial motor control, power distribution switching, and automation systems. It is a cost-effective choice from a leading domestic brand.
- Modell & Part Number Explanation
| Modellteil | Beschreibung |
| CJX2 | Series code (CJ = AC contactor, X2 = 2nd generation) |
| 40 | Rated operational current of main poles: 40A (AC‑3, 380V) |
| 11 | Hilfskontakte: 1 NEIN (Normalerweise geöffnet) + 1 NC (Normalerweise geschlossen) |
| Common coil voltages | AC24V / AC36V / AC110V / AC220V / AC380V (select as required) |
- Core Technical Specifications
| Artikel | Spezifikation | Notizen |
| Marke & Modell | CHNT CJX2-4011 | Compatible with Schneider LC1-D40 series |
| Polen | 3P (3 main poles) | For three‑phase AC loads |
| Nennstrom (Dh) | 40A (AC‑3, 380V) | Suitable for 18.5kW three‑phase motor |
| Rated operational voltage (Ue) | Max. AC690V | Normal use: AC380V/400V |
| Control coil voltage | Multi‑range optional (AC24/36/110/220/380V) | Must match control circuit voltage |
| Bruchkapazität | AC‑3: 40A; AC‑1: 110A | Meets general industrial load switching |
| Hilfskontakte | 1 NEIN + 1 NC | For status feedback and interlocking |
| Montage | 35mm DIN rail + screw fixing | Fits standard electrical cabinets |
| Wiring capacity | Hauptsächlich: 4~10mm² Cu; Spule: 1.5~2.5mm² | |
| Mechanisches Leben | ≥ 10 Millionen Operationen | Reliable for frequent use |
| Elektrisches Leben | ≥ 1 Millionen Operationen (AC‑3) | Silver alloy contacts for durability |
| Operating temp | -5℃ ~ +40℃ | For standard industrial environments |
| Schutzgrad | IP20 | Prevents finger contact with live parts |
- Merkmale & Vorteile
- High-reliability contact system
Silver alloy contacts offer good conductivity, anti-welding, and arc resistance
32-sheet silicon steel core for stable, low-noise operation (≤55dB)
Red copper coil + flame-retardant housing for high temperature resistance
- Dual mounting flexibility
Standard 35mm DIN rail for quick installation
Also supports screw mounting for panel installation
- Energy saving
Low power consumption for long-term operation
Stable coil pull-in, reduced control circuit energy use
- Strong compatibility
Directly matches CHNT NR2 series thermal overload relays
Dimensions compatible with Schneider LC1-D40 series for direct replacement
- Installation & Wiring Guide
4.1 Installationsanforderungen
DIN rail: Clip onto 35mm standard rail and ensure full locking
Screw mounting: Use M4 screws on a flat surface with ≥10mm clearance for heat dissipation
Prefer vertical installation; avoid horizontal mounting
4.2 Wiring Specification
| Terminal Type | Marking | Beschreibung | Cautions |
| Main poles | L1, L2, L3 (Linie); T1, T2, T3 (laden) | Connect three‑phase power / Motor | Disconnect power before wiring; torque 0.8~1.2N·m |
| Spule | A1, A2 | Connect to control circuit (pushbutton, SPS) | Coil voltage must match; do not reverse polarity |
| Auxiliary | NEIN (13‑14), NC (21‑22) | Feedback / interlock circuit | Distinguish NO/NC correctly |
4.3 Key Wiring Notes
Do NOT mix main pole and coil terminals
Securely crimp wires to avoid overheating
When used with a thermal relay, connect it after T1/T2/T3
- Typische Anwendungen
Three-phase motor control: 7.5kW~18.5kW pumps, Fans, Förderer
Industrielle Stromverteilung: cabinet switching, capacitor bank control
Automated production lines: PLC-controlled start/stop and interlock
Building systems: HVAC, Aufzüge, fire pumps
Machine tools: lathes, milling machines, drilling machines
- Ersatzmodelle & Kompatibilität
6.1 CHNT Upgraded Replacements
| Original | Ersatz | Key Difference | Anwendung |
| CJX2-4011 | NXC-4011 | Kunlun series, upgraded contacts, smaller, lower power | New panels, system upgrades |
| CJX2-4011 | CJX2-4001 | 1 NC only | Fault feedback only |
| CJX2-4011 | CJX2-4022 | 2 NEIN + 2 NC | Complex interlocking |
6.2 Cross-Brand Equivalents
| Marke | Equivalent Model | Matching Specs |
| Schneider | LC1-D4011M5C | 40A, 3P, 1NO+1NC, AC220V coil |
| Siemens | 3TF4722-0XM0 | 40A, 3P, 2NO+2NC |
| ABB | A40-30-11 | 40A, 3P, 1NO+1NC |
| Lecker | CJX2-4011 | Directly interchangeable |
- Purchasing & Nutzungstipps
- Authenticity
Buy via official channels to avoid counterfeits
Verify model, coil voltage, and poles
- Zubehör
Must use with NR2 thermal relay for motor overload protection
Surge suppressor (SR2 series) recommended for frequent switching
- Selection Rules
AC-3 for motors; AC-1 for resistive loads
Coil voltage must match control power
Higher protection grade for dusty/humid environments
- Wartung
Check terminal tightness every 6–12 months
Clean contacts and replace if worn
Energize briefly before long-term storage
> Notiz: CJX2-4011 is a general-purpose contactor with high cost-performance, stabile Versorgung, and easy replacement. Widely used in machinery, chemisch, building materials, light industry.
Complete CHNT AC Contactor Series-Models & Order Codes
Core Overview
CHNT AC contactors cover 5 main series:
CJX2 (classic), NXC (Kunlun upgrade), NC1 (industrial IEC), NC2 (high current), NC8 (high voltage heavy duty).
Models are coded by current + Hilfskontakte + coil voltage.
Order codes start with 710010xxxx and cover 6A ~ 1250A.
- CJX2-Serie (Classic, auslaufen)
Anwendung: Small-medium motors, 35mm DIN rail, compatible with Schneider LC1-D.
| Modell | Key Specs | Typical Order Code (AC220V) | Motor |
| CJX2-0610 | 6A, 1NEIN | 7100102000610220 | 2.2kW |
| CJX2-0910 | 9A, 1NEIN | 7100102000910220 | 4kW |
| CJX2-1210 | 12A, 1NEIN | 7100102001210220 | 5.5kW |
| CJX2-1810 | 18A, 1NEIN | 7100102001810220 | 7.5kW |
| CJX2-2510 | 25A, 1NEIN | 7100102002510220 | 11kW |
| CJX2-3210 | 32A, 1NEIN | 7100102003210220 | 15kW |
| CJX2-4011 | 40A, 1NO+1NC | 710010200403220 | 18.5kW |
| CJX2-5011 | 50A, 1NO+1NC | 7100102005011220 | 22kW |
| CJX2-6511 | 65A, 1NO+1NC | 7100102006511220 | 30kW |
| CJX2-9511 | 95A, 1NO+1NC | 7100102009511220 | 45kW |
> Notiz: 01=1NC, 10=1NO, 11=1NO+1NC. Coil voltages: AC24/36/110/220/380V. Last 3 digits = voltage code.
- NXC Series (Kunlun Upgrade, Mainstream)
Anwendung: CJX2 replacement, smaller, lower power, longer life.
| Modell | Key Specs | Typical Order Code (AC220V) | Anwendung |
| NXC-06 | 6A, 1NEIN | 710010100000498 | Small motor, Beleuchtung |
| NXC-09 | 9A, 1NEIN | 710010100000499 | Pumps, Fans |
| NXC-12 | 12A, 1NEIN | 710010100000500 | Small machines, A/C |
| NXC-18 | 18A, 1NEIN | 710010100000501 | 7.5kW motor |
| NXC-25 | 25A, 1NEIN | 710010100000502 | 11kW motor |
| NXC-32 | 32A, 1NEIN | 710010100000503 | 15kW motor |
| NXC-40 | 40A, 1NO+1NC | 710010100000504 | 18.5kW motor |
| NXC-50 | 50A, 1NO+1NC | 710010100000505 | 22kW motor |
| NXC-65 | 65A, 1NO+1NC | 710010100000506 | 30kW motor |
| NXC-80 | 80A, 2NO+2NC | 710010100000507 | 45kW motor |
| NXC-100 | 100A, 2NO+2NC | 710010100000508 | 55kW motor |
| NXCQ-40 | 40A, mechanical emergency | 710010100002345 | Fire pump |
> Notiz: Z = DC coil (z.B., NXC-12Z DC24V); M = mechanical latching.
- NC1 Series (Industrial IEC Standard)
Anwendung: International standard, high reliability, frequent operation.
| Modell | Key Specs | Typical Order Code (AC230V) | Coil Type |
| NC1-0910 | 9A, 1NEIN | 7100161000910230 | Wechselstrom |
| NC1-1201 | 12A, 1NC | 7100161001201230 | Wechselstrom |
| NC1-2511 | 25A, 1NO+1NC | 7100161002511230 | Wechselstrom |
| NC1-4011 | 40A, 1NO+1NC | 71001610804011200 | Wechselstrom |
| NC1-6511 | 65A, 1NO+1NC | 71001610806511200 | Wechselstrom |
| NC1-9511 | 95A, 1NO+1NC | 71001610809511200 | Wechselstrom |
| NC1-1210Z | 12A, 1NEIN | 710016121210024 | DC24V |
| NC1-2501Z | 25A, 1NC | 7100161212501020 | DC24V |
> Notiz: NC1-N = reversing contactor. Z = DC coil.
- NC2-Serie (High Current Industrial)
Anwendung: Heavy motors & main circuits up to 800A.
| Modell | Key Specs | Typical Order Code (AC220V) | Anwendung |
| NC2-150 | 150A, 3P | 7100162001501220 | Main switch, large fan |
| NC2-225 | 225A, 3P | 7100162002251220 | Air compressor |
| NC2-400 | 400A, 3P/4P | 7100162004001220 | Rechenzentrum |
| NC2-630 | 630A, 3P/4P | 7100162006301220 | Große Ausrüstung |
| NC2-800 | 800A, 3P/4P | 7100162008001220 | Haupteinnehmer |
> Notiz: 3P/4P available. Rangierfahrt, undervoltage release optional.
- NC8 Series (High Voltage Heavy Duty)
Anwendung: Up to 1140V, 2650A for metallurgy, Bergbau, marine.
| Modell | Key Specs | Typical Order Code (AC220V) | Anwendung |
| NC8-12M10 | 12A, 1NEIN | 71001680001210200 | High-voltage auxiliary |
| NC8-25M11 | 25A, 1NO+1NC | 71001680002511200 | HV motor control |
| NC8-40M22 | 40A, 2NO+2NC | 71001680004022200 | HV cabinet |
| NC8-100M22 | 100A, 2NO+2NC | 71001680010022200 | Large HV motor |
| NC8-500M22 | 500A, 2NO+2NC | 71001680050022200 | Bergbau, marine |
> Notiz: M = mechanical latching. 4P for 3P+N systems. DC coil available.
- General Selection & Order Code Rules
6.1 Model Coding
| Position | Bedeutung | Beispiel (CJX2-4011 AC220V) |
| Prefix | Serie | CJX2, NXC, NC1 |
| Middle | Nennstrom (AC‑3, 380V) | 40 = 40A |
| Suffix 1 | Hilfskontakte | 11 = 1NO+1NC |
| Suffix 2 | Poles/function | /4 = 4P; /Z = DC; /M = latching |
6.2 Order Code Format
Standard: 710010xxxxxxx
Beispiel:
CJX2-4011 AC220V → 710010200403220
NXC-12 DC24V → 710010100000500Z
6.3 Wichtige Auswahlpunkte
- Load: AC-3 for motors; AC-1 for resistive loads
- Coil voltage must match control power
- Hilfskontakte: 10, 01, 11, 22
- Polen: 3P for three-phase; 4P for 3P+N
- Series Comparison & Recommendation
| Serie | Aktuell | Key Strength | Anwendung |
| CJX2 | 6A~95A | Mature, low cost, compatible | Retrofit, general use |
| NXC | 6A~100A | Klein, low power, long life | New projects, automation |
| NC1 | 9A~95A | IEC standard, high reliability | Export, frequent duty |
| NC2 | 150A~800A | High current, heavy duty | Industrie, data center |
| NC8 | 12A~2650A | HV, extreme environment | Metallurgie, Bergbau, marine |
Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien
















NH42-63-318x560.png)