Danfoss SM147A4ALB Scrollkompressor

(Performer hermetischer Scrollkompressor) Bestell-Nr.: 120H0191, a fixed-speed scroll unit from the Danfoss SM series, designed for R22 central air conditioning applications. ✅ Model Decoding SM: Performer scroll series, air-conditioning duty 147: Displacement size 193.5 cm³/rev A: Motorversion 4: 3-phase 380~415V 50Hz / 460V 60Hz ALB: Oil sight glass, internal motor protection, ODF ...

  • Produktdetails

(Performer hermetisch scroll compressor)

Bestell-Nr.: 120H0191, a fixed-speed scroll unit from the Danfoss SM series, designed for R22 central air conditioning applications.

✅ Modelldekodierung

SM: Performer scroll series, air-conditioning duty

147: Displacement size 193.5 cm³/rev

A: Motorversion

4: 3-phase 380~415V 50Hz / 460V 60Hz

ALB: Oil sight glass, internal motor protection, ODF-Lötverbindungen, no economizer

📌 Technische Kernspezifikationen

ArtikelParameter
KältemittelR22 (compatible only with R22 mineral oil 160P)
Stromversorgung3Ph 380–415V 50Hz / 460V 60Hz
Kühlleistung32.6kW@50Hz;43.6kW@60Hz
Verschiebung193.5 cm³/r
Rotation Speed2900U/min(50Hz) / 3500U/min(60Hz)
RLA Rated Load Current20.7A
LRA Locked Rotor Current147A
MOC Maximum Operating Current26A
Nettogewicht67 kg, Bruttogewicht 71.75 kg
Pipe ConnectionsODF brazed, discharge 7/8″
GliederungOuter diameter φ243mm, height 509mm
ZertifizierungenCE / UL / UKCA
KapazitätskontrolleFixed speed, no variable frequency
Economizer❌ No subcooler/economizer port
Maximale Kältemittelfüllung7.9kg

🧊 Typische Anwendungen

Kommerziell luftgekühlt / wassergekühlte zentrale Klimaanlagen

Modulare Kältemaschinen, Nachrüstung eines Schraubenkompressors, industrielle Wasserkühler

Kommerzielle konstante Temperatur & Feuchtigkeitsklimaanlagen (Nur R22-System; R407C/R410A-Modelle können nicht direkt ersetzt werden)

⚠️ Wartung & Auswahlnotizen

  1. Kühlöl: 160P Mineralöl. POE-Synthetiköl darf nicht gemischt werden. Der Austausch des Kompressors erfordert gleichzeitig Öl & Ölfilterwechsel.
  2. Eingebauter thermischer Motorschutz. Es werden ein externer Phasenfolgeschutz und ein Hoch-/Niederdruckschutz empfohlen.
  3. Betrieb mit einer Einheit; Die parallele Installation mehrerer Kompressoren erfordert eine Ölausgleichslösung (Ölausgleichsanschlussgröße 1-3/4″ Rotolock).
  4. Maximal zulässiger Betriebsdruck: Hohe Seite 29,4 bar, Niederdruckseite 25bar.
  5. Schwerpunkt der Gebrauchtinspektion: Isolationswiderstand, Test zwischen den Runden, Ölfarbe, internes ungewöhnliches Geräusch, Hoch-/Niederdruck-Lecktest.

🔁 Äquivalent / Alternative Referenzen

SM147A3ALB: Andere Spannungsversion (Code 3)

SM147A4CLB: Difference in connection and accessory configuration

SZ147A4ALB: Same displacement, for R407C (nicht direkt austauschbar; refrigerant and lubricant differ)

SM147A4ALB Starting & Protection Circuit Selection List (3Ph 380~415V/50Hz, R22 Performer Scroll)

Compressor base electrical data: RLA=20.7A; MOC maximum continuous operating current=26A; LRA locked rotor current=147A; The compressor has built-in motor thermal protection. Complete external electrical and refrigerant pressure protection is still mandatory.

  1. Main Circuit Component Selection
KomponenteSpezifikationBemerkungen
3-phase Main ContactorAC-3 400V ≥32A, coil AC220V/AC380V optionalSchneider LC1D32, LC1E32; AC-3 rated to withstand LRA inrush. AC-1 contactors are prohibited.
MCCB Molded Case Circuit BreakerType D 3P, rated 40A, instantaneous trip 10InType D for motor starting inrush, Kurzschlussschutz. Type C not permitted.
Thermisches ÜberlastrelaisEinstellbereich:18~24A, 3P, manueller ResetSetpoint approx. 21A; fungiert als sekundärer Backup-Überlastschutz und kann den internen Thermoschutz des Kompressors nicht ersetzen.
HauptstromkabelKupfer ≥4mm² StromkabelEinzelgerät, Länge ≤30m; Upgrade auf 6 mm² für lange Läufe, Crimpkabelschuhe verwenden
Kurbelgehäuseheizung220V, 80W, AC220VÖlsumpfheizung; Minimum 8 Stunden Vorheizen vor dem Start. Unabhängig vom Heizkreis und abgeschaltet, bevor der Kompressor startet.
  1. Kältemitteldruckschutz (Sicherheitskette in Reihe mit dem Schützspulenkreis verdrahtet)
GerätEmpfohlenes ModellEinstellungReset-Modus
HochdruckschalterDanfoss KP5 (Hochdruck)Reise:27Bar; Zurücksetzen:21BarManueller Reset (obligatorisch), R22-Service
NiederdruckschalterDanfoss KP1 (Niederdruck)Reise:1.8Bar; Zurücksetzen:3.2BarAutomatischer Reset, Schützt vor Flüssigkeitsrückfluss bei geringer Saugleistung / niedrige Kältemittelfüllung
Öldifferenzdruckschutz (optional)Danfoss MP54Auslösung bei Öldifferenzdruck <2.5Bar mit 120s VerzögerungFür große Kühler dringend empfohlen

III. Phasenfolge & Phasenausfallschutz (obligatorisch)

Phasenfolge / Phasenausfallrelais: 3-Phase 380V, erkennt falsche Phase, Phasenverlust & 3-Phasenunsymmetrie

Empfehlung: Schneider RM22TG20 oder dreiphasiges Haushaltsschutzrelais

Logik: Unterbrechen Sie die Schützspule bei abnormalem Phasenzustand. Durch die Rückwärtsdrehung des Scrollkompressors kann die Scrollhülle innerhalb von Sekunden zerstört werden.

  1. Steuerkreis (AC220V-Steuerung)
  2. Steuerversorgung: AC220V mit C10-Miniaturschutzschalter (10A)
  3. Reihensicherungskette für Spulenkreis: Phasenfolgeschutz NC → Hochdruckschalter NC → Niederdruckschalter NC → Öldifferential (optional NC) → Start-/Stopp-Taste → Schützspule
  4. Hilfskontakte: Schütz-NO-Hilfskontakt zur Selbsthaltung; Fehleralarm über NO-Kontakte jedes Schutzgeräts verdrahtet.
  5. Harte Regeln für die Startsteuerung des Scroll-Kompressors
  6. Minimale Ausschaltverzögerung: Warte wenigstens 3 Minuten nach dem Herunterfahren vor dem Neustart; Für die Steuerung wird eine Mindeststoppverzögerung von 180 Sekunden empfohlen.
  7. Maximale Starts pro Stunde: ≤6 mal. Häufige Starts beschleunigen den Verschleiß von Lagern und Spiralwickel.
  8. Verbotene Operationen: Beginnen Sie mit der Druckdifferenz, Testen Sie die Drehung im Rückwärtsgang, Start ohne Kurbelgehäusevorwärmung.
  9. After internal protector trips: Power must be cut for cooling and reset. Do not repeatedly force power on for trial runs.
  10. Optional Sensors & Zubehör

Discharge temperature sensor (optional): PT100, discharge overtemperature protection for high-temperature R22 operation

Stromwandler (optional): 25/5A, for real-time current monitoring by unit controller

Terminals: Crimp lugs recommended for compressor terminals, tightening torque 3.5~4N·m per Danfoss manual

VII. Simplified Typical Control Sequence

Power on → Phase sequence self-check OK → Crankcase heater energized → Preheating timer satisfied → Start enable signal → Contactor pulls in, compressor runs.

Trip on high pressure (manueller Reset), Niederdruck, Phasenverlust / wrong phase: contactor de-energized immediately, unit stops and triggers fault alarm.

VIII. Checkliste für Auswahlfallen

  1. Thermal relay is only backup protection. The compressor built-in thermal protector will activate first. Do not use thermal relay as sole motor protection.
  2. High pressure protection must use manual reset. Auto-reset high pressure switches violate safety requirements.
  3. Phase sequence protection must never be omitted; reverse rotation can ruin scroll plates in tens of seconds.
  4. Crankcase heater cannot be omitted. For R22 mineral oil, refrigerant dissolves in oil at low standby temperature; startup without preheating risks bearing seizure from oil starvation.

Danfoss Performer SM Series (R22 fixed-speed scroll, single unit) Vollständige Modellliste

SM series: R22 refrigerant, mineral oil 160P, air-conditioning scroll compressors; SZ series of same footprint for R407C; SY series covers larger displacement range.

Benennungsregel: SM+displacement code+motor code+voltage code+suffix (connections/accessories); Code 4 = 380~415V 50Hz /460V 60Hz (main domestic engineering variant; SM147A4ALB uses code 4)

  1. Base Displacement Core Models (bare unit without ALB/CLB suffix)
BasismodellDisplacement cm³/revCooling Capacity kW@50HzBemerkungen
SM084112.0816.1Small modular units, Gebläsekonvektoren
SM090120.517.3Air-cooled modular, large residential central AC
SM100127.218.5Commercial air conditioning
SM110144.220.8Water chillers
SM112151.522.1Short body version
SM115156.823
SM120166.624.6Mainstream modular chiller model
SM124169.525.4Kurzer Körper
SM147193.532.6Bare model of your SM147A4ALB
SM148194.533SM147 upgraded variant
SM160210.135.4Medium water chillers
SM161216.636.6
SM17022938.8
SM17523340.2
SM18024141.8
SM185249.943.7Largest single unit in SM range
SM200254.446.1Older large SM, mostly superseded by SY series for new projects
SM220288.452.7Older large SM
SM242333.261.3Older large SM
SM24834264Older large SM
SM444597117Built-in tandem parallel compressor
SM483649.8127Built-in tandem parallel compressor
  1. SM147 Full Suffix Variants (subfamily of your compressor)

SM147 bare unit, voltage codes: 3 /4 /9

SM147A3ALB: Spannungscode 3 Variante

SM147A4ALB: Ihr Modell, 380~415V 50Hz, ODF brazed ports, oil sight glass, no economizer, Order No.120H0191

SM147A4CLB: Different connection style, Rotolock port

SM147A9ALB: 60Hz North American voltage version

Suffix-Erklärung:

ALB = ODF brazed pipe connections, oil sight glass, internal thermal protection, no economizer

CLB = Rotolock flange connections, oil sight glass, internal thermal protection

III. Voltage Code Definition (middle digit of model)

3: 200–230V 3-phase 60Hz

4: 380–415V 50Hz /460V 60Hz (main domestic engineering model)

9: 380V 3-phase 60Hz (North American unit)

  1. Platform Differentiation (avoid selection error)
  2. SM: R22, mineral oil 160P (this list)
  3. SZ: Same outer dimensions, R407C, POE synthetic oil, cannot directly replace SM
  4. SY: Larger displacement range, R22, high-capacity water chillers (SY240, SY300, SY380, SY550 etc., not part of SM series)
  5. End-of-Life Notice

SM200/SM220/SM242/SM248 are legacy large SM models, mostly discontinued. New projects are recommended to adopt SY series. SM084~SM185 remain mainstream stocked models.

Danfoss Performer SM Series (R22) Current Parameter Table

Notiz: Power supply 3Ph 380~415V 50Hz; RLA=Rated Load Current; MOC=Maximum Continuous Operating Current; LRA=Locked Rotor Current; all single units, tandem compressors listed separately.

ModellDisplacement cm³/revCooling Capacity kW@50HzRLA(A)MOC(A)LRA(A)
SM084112.0816.111.214.184
SM090120.517.312.115.290
SM100127.218.512.81694
SM110144.220.814.418106
SM112151.522.114.818.5108
SM115156.82315.419.3112
SM120166.624.616.220.3118
SM124169.525.416.620.8122
SM147193.532.620.726147
SM148194.5332126.3149
SM160210.135.422.528.1160
SM161216.636.623.229163
SM17022938.824.330.4171
SM17523340.225.131.4176
SM18024141.82632.5182
SM185249.943.72733.8188
SM200254.446.128.435.5196
SM220288.452.732.240.3222
SM242333.261.336.846254
SM2483426438.247.7262

Tandem Integrated Compressors (dual scroll block)

ModellDisplacement Cm³/revCooling Capacity kW@50HzRLA(A)MOC(A)LRA(A)
SM44459711764.580.6440
SM483649.812770.287.8478

Ergänzende Hinweise

  1. This table applies to suffix code 4 Versionen (A4ALB/A4CLB). Code3/9 variants (220V 3-phasig, 60Hz North America) have different current values and must not use this table.
  2. Thermal overload relay setting recommendation: RLA × 1.02 ~ 1.05, used as backup protection and shall not exceed MOC.
  3. LRA locked rotor current is used for contactor and circuit breaker short-time inrush sizing only, not continuous current rating.
  4. SM series only works with R22 + 160P mineral refrigeration oil; SZ-Serie (R407C) of identical external shape has different current parameters and shall not be mixed.