SPIDER-1TX/1FX-SM: Hirschmann Industrial Ethernet Rail Switch
SPIDER-1TX/1FX-SM is an entry-level unmanaged industrial Ethernet media conversion switch launched by Hirschmann Automation, a subsidiary of Belden. It is specially designed for harsh environments such as industrial automation and marine control, enabling seamless conversion between twisted pair (TP) and single-mode fiber (SM), supporting long-distance data transmission and strong anti-interference capability.
- Core Identification & Grundlegende Informationen
| Parameter | Spezifikation |
| Hersteller | Hirschmann (Hirschmann Automation and Control GmbH, a Belden brand) |
| Modell | SPIDER-1TX/1FX-SM (Standard Order No.: 943928001) |
| Produkttyp | Unmanaged industrial Ethernet switch / media converter |
| Montage | Standard 35 mm DIN rail mounting (snap-in type) |
| Schutz vor Eindringen | IP30 (for installation in control cabinets) |
| Verschmutzungsgrad | Entspricht IEC 60664-1 Verschmutzungsgrad 2 |
| Laser Class | Entspricht IEC 60825-1 Klasse 1 laser product (sicher, no radiation risk) |
- Grundlegende technische Spezifikationen
- Port Configuration
| Port Type | Quantity | Spezifikation | Connection Notes |
| 10/100BASE-TX Twisted Pair Port | 1 | RJ45, auto crossover, auto-negotiation, auto polarity detection | Max transmission distance 100 M, suitable for 0.5~2.5 mm wires |
| 100BASE-FX Single-Mode Fiber Port | 1 | Duplex SC connector, 9/125 渭m single-mode fiber | Max transmission distance 32.5 km (1300 nm wavelength, 16 dB link budget) |
- Switching & Forwarding
Switching Mode: Store and Forward
Supported Standards: IEEE 802.3 (10 Mbit/s), IEEE 802.3u (100 Mbit/s)
MAC Address Table Capacity: Max 1000 MAC addresses
Frame Filtering: Automatically discards CRC error frames and fragment frames (< 64 bytes)
- Leistung & Stromverbrauch
| Parameter | Spezifikation | Bemerkungen |
| Betriebsspannungsbereich | 9.6~32 VDC (wide voltage compatible) | Unterstützt 12 VDC / 24 VDC industrial power supplies, built-in SELV safety isolation |
| Max Power Consumption | ≤ 3.0 W (bei 24 VDC) | Ca. 10.2 Btu/h, low-power design |
| Current Consumption | Max 130 mA at 24 VDC | Typical approx. 80 mA |
| Power Terminal | 3-pin pluggable terminal block, no signal pins | Terminal tightening torque: 0.5 Nm |
| Grounding Method | Grounded via the grounding pin of the power terminal block | Ensure reliable grounding for improved anti-interference |
- Umweltanpassungsfähigkeit
| Parameter | Spezifikation | Bemerkungen |
| Betriebstemperatur | -40°C ~ +70°C (wide-temperature design) | Suitable for extreme environments such as polar regions, Schiffe, Metallurgie |
| Lagertemperatur | -40°C ~ +85°C | Safe storage under extreme conditions |
| Relative Luftfeuchtigkeit | 10% ~ 95% (nicht kondensierend) | Adaptable to high-humidity marine/industrial environments |
| Vibration Resistance | IEC 60068-2-6: 3.5 mm amplitude, 1~150 Hz, 1 g acceleration | Complies with industrial equipment vibration standards |
| Shock Resistance | IEC 60068-2-27: 15 g acceleration, 11 ms duration | Resists transportation and on-site vibration |
- Electromagnetic Compatibility (EMV)
Immunity: IN 61000-4-2 (ESD), IN 61000-4-3 (radiated field), IN 61000-4-4 (fast transients), IN 61000-4-5 (surge)
Emission: IN 55032 Class A, FCC 47 CFR Teil 15 Class A
Industrial Standard: IN 61000-6-2 (immunity for industrial environments)
- Zuverlässigkeit & Zertifizierungen
Mean Time Between Failures (MTBF): 101.5 Jahre (MIL-HDBK 217F, 25°C)
Safety Certifications: cUL 508, CSA 22.2 No.142
Industrial Standard: Entspricht IEC 61131-2 (standard for programmable controllers)
- Stift & Wiring Configuration
- Power Terminal Block (3-Stift)
| Pin No. | Funktion | Wiring Description |
| 1 | GND (Ground) | Equipment grounding terminal, must be reliably connected to industrial ground |
| 2 | V- (Negative Power) | Connect to DC power negative (0 V) |
| 3 | V+ (Positive Power) | Connect to DC power positive (9.6~32 VDC) |
- RJ45 Port Pinout (10/100BASE-TX)
| Stift | Signal | Funktion |
| 1 | TX+ (Transmit+) | Data transmit positive |
| 2 | TX- (Transmit-) | Data transmit negative |
| 3 | RX+ (Receive+) | Data receive positive |
| 4 | Not used | Reserved |
| 5 | Not used | Reserved |
| 6 | RX- (Receive-) | Data receive negative |
| 7 | Not used | Reserved |
| 8 | Not used | Reserved |
- Fiber Port (SC Connector)
Uses duplex SC interface; requires connection of single-mode fiber transceiver pair (TX/RX cross-connected)
Fiber type: 9/125 μm single-mode fiber, wavelength 1300 nm
- LED Status Indicators
| LED Name | Farbe | Status | Bedeutung |
| P (Leistung) | Grün | Solid ON | Power supply normal |
| DA/STAT | Grün | Solid ON | Valid link established on port |
| DA/STAT | Grün | Blinking | Data traffic active on port |
| DA/STAT | Off | No link | Port not linked or faulty |
| 10/100 (Speed) | Gelb | Solid ON | 100 Mbps connection |
| 10/100 (Speed) | Off | 10 Mbps connection |
- Physikalische Eigenschaften
| Parameter | Spezifikation |
| Abmessungen (B×H×T) | 25 mm × 114 mm × 79 mm (1.0″ × 4.5″ × 3.2″) |
| Gewicht | Ca. 105 G (0.23 lb) |
| Gehäusematerial | Flame-retardant ABS plastic, compliant with industrial safety standards |
| Wire Size | Twisted pair: 0.5~2.5 mm²; power terminals: 0.5~1.5 mm² |
- Merkmale & Vorteile
- Plug-and-play: No configuration required, operates immediately after power-on, ideal for fast deployment
- Long-distance transmission: Single-mode fiber supports up to 32.5 km, exceeding the 100 m limit of twisted pair
- Strong anti-interference: Industrial-grade EMC design, suitable for strong electromagnetic interference environments (z.B., near motors, inverters)
- Wide-temperature operation: Cold start at -40°C, stable operation at 70°C, suitable for outdoor/polar applications
- Link protection: Supports Far-End Fault and Low Light Detection to improve network reliability
- Auto-adaptation: RJ45 port auto-negotiates speed, duplex mode, and auto-crossover cable, simplifying wiring
- Typische Anwendungen
- Industrielle Automatisierung: Steuerung der Produktionslinie, PLC networking, sensor data acquisition
- Shipbuilding & Meerestechnik: Ship automation systems, offshore platform control, remote equipment monitoring
- Intelligent transportation: Traffic signal control, tunnel monitoring, railway signaling systems
- Energie & Leistung: Substation monitoring, wind/PV systems, power transmission and distribution control
- Chemisch & metallurgical: Remote control in hazardous areas, networking in high-temperature/humidity conditions
- Fernüberwachung: Cross-regional equipment networking, fiber optic relaying to extend coverage
- Installation & Wartungsrichtlinien
- Installationsregeln
Ensure firm rail mounting to avoid loosening
Maintain at least 10 cm ventilation space around the device to prevent heat buildup
For wiring: connect ground first, then power cables, and finally signal cables
Do not open the housing while the device is powered
- Wartungsempfehlungen
Regularly check LED status for quick network fault diagnosis
Inspect cleanliness of power terminals and fiber interfaces every 6 Monate
Keep fiber ports free of dust; clean with professional fiber cleaning tools
For faults, first check power and physical link connections; disassembly by non-professionals is prohibited
- Alternative Modelle & Kompatibilität
| Alternatives Modell | Marke | Kompatibilitätshinweise |
| SPIDER-1TX/1FX-SM-EEC | Hirschmann | Erweiterte Version, supports wider voltage and higher temperature |
| RH1-TP/FO-SM | Hirschmann | Same-spec media converter, slightly different appearance |
| IEF-1100-SM | Phoenix Contact | Funktionell kompatibel; note differences in pinout and dimensions |
- Important Notes
- Power Safety: Only SELV (Safety Extra-Low Voltage) power supplies must be used; AC mains input is strictly prohibited
- Fiber Connection: Single-mode and multi-mode fiber must not be mixed; SC connectors must match fiber type
- Environmental Restriction: Do not use in explosive hazardous areas (Klasse I, Division 2) unless specially certified
- Cable Selection: Industrial shielded twisted pair (STP) is recommended for improved anti-interference
- Grounding Requirement: Reliable grounding is mandatory; ansonsten, equipment damage or unstable communication may occur
Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien