LUCA05BL is a standard control unit of Schneider’s TeSys U series, suitable for three-phase motors. It features an adjustable rated current of 1.25–5A, a control voltage of 24V DC, and a Class 10 thermal overload rating. Equipped with protection against overload, Kurzschluss, Phasenverlust, phase interruption, and ground fault, it is designed for direct-on-line ...

  • Produktdetails

LUCA05BL is a standard control unit of Schneider’s TeSys U series, suitable for three-phase motors. It features an adjustable rated current of 1.25–5A, a control voltage of 24V DC, and a Class 10 thermal overload rating. Equipped with protection against overload, Kurzschluss, Phasenverlust, phase interruption, and ground fault, it is designed for direct-on-line starting control of motors below 1.5kW (400V).

ParameterWertBeschreibung
Kompatible SerienTeSys UStandard-Steuergerät (LUCA-Serie)
Nennstrom (Und)1.25-5AEinstellbar; rated continuous current (Iu)=5A
Steuerspannung24In DCOperating voltage of the control circuit
Thermal Overload ClassKlasse 10Entspricht IEC 60947-4-1
Hauptstromkreisspannung≤690 V WechselstromGeeignet für Drehstrommotoren
Motorleistung (400V)≤1,5 kWDreiphasig, 50/60Hz
Kurzschlussschutz65A (augenblicklich)Nicht verstellbar
SchutzfunktionenOverload/Short Circuit/Phase Loss/Current Unbalance/Ground FaultManual reset required
Abmessungen (B×H×T)45×66×60mmStandard modular installation
HerkunftsortFrankreichOriginal imported product

Produktpositionierung & Anwendungen

– As a standard control unit of the TeSys U series, it combines with compatible power bases (z.B., LUB05) to form a direct-on-line starter, providing basic control and protection for three-phase motors.

Anwendungsszenarien: Light to medium-load working conditions such as pumps, Fans, Kompressoren, and small conveyor lines, suitable for industries including textile, Papierherstellung, chemical engineering, and food & Getränk.

Differentiation from Series Peers: Unlike LUCB (advanced type with alarm/test functions) and LUCC (communication type), LUCA only provides basic protection with a lower cost.

Auswahl & Ersatz

Compatible Bases: LUB05, LUB05BL, usw. The base must match the rated current of the control unit.

Ersatzreferenzen: Equivalent models from Chint NJR2 series and ABB MS116 series. Jedoch, interface and protection logic differences exist; it is necessary to verify installation dimensions and control circuit parameters.

Installation & Wartungsrichtlinien

  1. Install via DIN rail or screw mounting; modular plug-and-play design enables quick replacement.
  2. The control circuit requires an external 24V DC power supply. Set Ir (1.25-5A) on the main circuit according to the motor’s rated current.
  3. Manual reset is required after a fault. Ground fault protection is only for equipment and does not replace personal safety protection.
  4. Betriebstemperaturbereich: -25~+60℃. Avoid dusty, feucht, und korrosiven Umgebungen; regularly check wiring and terminal tightness.

Beschaffung & Liefern

Common Channels: Schneider authorized distributors, industrial e-commerce platforms. Referenzpreis: approximately €60–100 (inklusive Mehrwertsteuer). In-stock delivery typically takes 2–5 working days.

Kompatibles Zubehör: Can be paired with LUFDA local alarm module and LULC remote signal module to expand status monitoring functions.

Detailed Comparison Between Schneider TeSys U Series LUCA05BL and LUCB05BL

VergleichsdimensionLUCA05BL (Standardtyp)LUCB05BL (Advanced Type)
KernpositionierungBasic motor protection & direct-on-line starting controlVerbesserter Schutz + Fehleralarm + test functions
Nennstrombereich1.25-5A1.25-5A
Steuerspannung24In DC24In DC
Thermal Overload ClassKlasse 10 (IEC 60947-4-1)Klasse 10 (IEC 60947-4-1)
Kompatible Motorleistung (400V)≤1,5 kW≤1,5 kW
Hauptstromkreisspannung≤690 V Wechselstrom≤690 V Wechselstrom
Grundlegende SchutzfunktionenÜberlast, Kurzschluss, Phasenverlust, aktuelle Unsymmetrie, ErdschlussSame as LUCA05BL, plus overload pre-alarm function
Besondere MerkmaleManual reset only; no alarm/test functions1. Fehleralarmausgang: Relay contact signal, connectable to indicator lights or PLC
2. Manual test function: Simulate faults without power supply to verify protection logic
3. Statusanzeige: Multi-color LED distinguishes running/overload/short circuit/phase loss status
Methode zurücksetzenManual reset onlyManueller Reset + external remote reset signal support (accessories required)
Modulare ZubehörkompatibilitätSupports basic bases only (z.B., LUB05)Compatible with LUFDA local alarm module and LULC remote signal module; supports expansion
InstallationsmethodeDIN rail/screw mounting; Plug-and-PlaySame as LUCA05BL; einheitliche Einbaumaße
AnwendungsszenarienLight/medium-load conditions without remote monitoring needs (z.B., kleine Pumpen, Fans)Scenarios requiring fault pre-alarm and status monitoring (z.B., automatisierte Produktionslinien, chemical equipment)
Kostenreferenz€60–100 (inklusive Mehrwertsteuer)€120–180 (inklusive Mehrwertsteuer), approximately twice the price of LUCA05BL
ErsatzkompatibilitätBase-compatible with LUCB05BL; direct plug-and-replaceDownward compatible with LUCA05BL replacement; redundant functions but higher cost

Zusammenfassung der wichtigsten Unterschiede

  1. Funktionelle Unterschiede: The core advantages of LUCB05BL are overload pre-alarm + Fehleralarm + manual test, which can detect motor overload trends in advance to avoid downtime losses. Im Gegensatz, LUCA05BL only provides post-fault protection with no pre-alarm capability.
  2. Erweiterungsfähigkeit: LUCB05BL can be connected to external alarm lights, SPS, or remote monitoring modules to adapt to automated systems; LUCA05BL has no expansion interface and only meets basic control needs.
  3. Kosten & Kosteneffizienz: LUCA05BL is suitable for cost-sensitive scenarios with simple working conditions; LUCB05BL is ideal for industrial scenarios requiring high reliability. Although it has a higher price, it can reduce fault troubleshooting time and maintenance costs.

Auswahlempfehlungen

– If end customers only require “basic motor protection against damage”, prioritize LUCA05BL for higher cost-effectiveness.

– If customers operate in scenarios such as automated factories and production lines that require fault pre-alarm and remote monitoring, recommend LUCB05BL to improve equipment operation rate.

Cross-Brand Selection Comparison Table: Schneider LUCA05BL/LUCB05BL vs. Chint NJR2-5 vs. ABB MS116-5

VergleichsdimensionSchneider LUCA05BLSchneider LUCB05BLChint NJR2-5ABB MS116-5
Positionierung der ProduktserieTeSys U standard control unitTeSys U advanced control unitNJR2 series thermal overload relayMS116 series motor starter protection circuit breaker
Nennstrombereich1.25-5A (einstellbar)1.25-5A (einstellbar)1.6-5A (einstellbar)1.6-5A (einstellbar)
Steuerspannung24In DC24In DCNo control circuit (passiv)No control circuit (passiv)
Thermal Overload ClassKlasse 10Klasse 10Klasse 10Klasse 10
Kompatible Motorleistung (400V)≤1,5 kW≤1,5 kW≤1,5 kW≤1,5 kW
Hauptstromkreisspannung≤690 V Wechselstrom≤690 V Wechselstrom≤660V AC≤690 V Wechselstrom
KernschutzfunktionenOverload/Short Circuit/Phase Loss/Current Unbalance/Ground FaultOverload+Short Circuit+Phase Loss+Current Unbalance+Ground FaultÜberlast, Phase Interruption, Current UnbalanceÜberlast, Kurzschluss, Phasenverlust, Current Unbalance
Overload Pre-Alarm, Fault Alarm OutputNo short circuit/ground fault protectionNo ground fault protection
Besondere MerkmaleManueller ResetManual/remote resetManual/automatic reset optionKnob-type current adjustment
Modular plug-and-playStörungsmeldekontaktKompakte Größe, niedrige KostenIntegrated circuit breaker function
Manual test functionManual closing/opening operation
Accessory expansion support
InstallationsmethodeDIN rail/screw mountingDIN rail/screw mountingDIN-SchienenmontageDIN-Schienenmontage
Requires TeSys U base (z.B., LUB05)Compatible with full range of TeSys U basesDirect combination with contactorsIntegriertes Design, no base required
AnwendungsszenarienLight-load conditions, cost-sensitive scenariosAutomatisierte Produktionslinien, fault pre-alarm required scenariosDomestic industrial supporting, low-end equipment supportingMid-to-high-end industrial scenarios requiring integrated circuit breaker functions
Kleine Pumpen/LüfterChemical/textile equipmentDistribution boxes/pumps & FansProduction lines/compressors
Kostenreferenz (Inklusive Steuern)€60–100€120–180RMB 80–150€90–160
ErsatzkompatibilitätBase-compatible with TeSys UBase-compatible with LUCA05BLEinfache Verkabelung; cross-brand replacement of international models requires mounting hole adjustmentIntegriertes Design; cross-brand replacement requires main circuit wiring matching
Cross-brand replacement requires wiring modificationDirect replacement for LUCA05BL

Key Selection Conclusions

  1. Chint for Cost Priority: NJR2-5 has the lowest price, suitable for domestic low-end equipment supporting, but lacks short circuit and ground fault protection and needs to be used with additional circuit breakers.
  2. ABB for Integrated Control: MS116-5 is an integrated protection circuit breaker with built-in closing/opening functions, requiring no base matching, suitable for scenarios with high integration requirements.
  3. Schneider LUCB for Automated Scenarios: Equipped with alarm and test functions, it can be connected to PLCs for remote monitoring, reducing fault troubleshooting time, ideal for high-end production lines.
  4. Schneider LUCA for Basic Protection: Balanced functions with a lower price than LUCB and ABB, suitable for overseas small and medium-sized customers without monitoring needs.

Export Adaptation Tips (For Markets Such as Algeria)

– Both Schneider and ABB products are certified by IEC and CE, directly meeting the import certification requirements of African countries such as Algeria.

– Chint NJR2-5 requires additional local access documents such as SASO certification. Some channels can handle the certification on behalf of customers, with a cost increase of approximately 10%–15%.

Vorher:

Nächste:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen