Mitsubishi FR-A840-18.5K High-Performance Inverter - Schütz,Leistungsschalter,Sensor,Encoder,SPS,Konverter

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

 Mitsubishi FR-A840-18.5K High-Performance Inverter - Schütz,Leistungsschalter,Sensor,Encoder,SPS,Konverter

Solarwechselrichter/

Mitsubishi FR-A840-18.5K High-Performance Inverter

FR:Inverter A:A800 high-performance series 8:8Generation 4:3-phase 400V class (380~500V) 0:Standard open type, IP20 18.5K:ND rated applicable motor power 18.5kW -1:Japanese domestic specification (corresponding China domestic model: FR-A840-00470-2-60) Core Electrical Specifications Input: 3-phase AC380~500V, 50/60Hz ND (Normal duty, Werkseinstellung): For 18.5kW motor, rated output current 38A, 150% overload for 60s LD (Leichte Pflicht): Antriebe ...

  • Produktdetails

FR:Wechselrichter

A:A800 high-performance series

8:8Generation

4:3-phase 400V class (380~500V)

0:Standard open type, IP20

18.5K:ND rated applicable motor power 18.5kW

-1:Japanese domestic specification (corresponding China domestic model: FR-A840-00470-2-60)

Grundlegende elektrische Spezifikationen

Eingang: 3-phase AC380~500V, 50/60Hz

ND (Normal duty, Werkseinstellung): For 18.5kW motor, rated output current 38A, 150% Überlastung für 60s

LD (Leichte Pflicht): Drives up to 22kW, Nennstrom 43A; SLD super light duty max 47A

HD Heavy duty mode: For 15kW motor, 31A, 180% Überlastung für 60s (selected for cranes, extruders and other high-shock loads)

Ausgangsfrequenz: 0.2~590Hz; max 400Hz under vector control

Built-in braking transistor (18.5kW model includes built-in braking transistor, externer Bremswiderstand anschließbar)

Schutzklasse: IP20 (cabinet mounting)

Kontrollieren Sie die Leistung

  1. Sensorlose Vektorsteuerung: Hohes Drehmoment bei niedriger Drehzahl, 200% torque output at 0.5Hz; supports asynchronous motor + PM permanent magnet synchronous motor drive, motor auto-tuning
  2. V/F-Steuerung, advanced magnetic flux vector; closed-loop vector available with encoder option card FR-A8AP
  3. Built-in simple PLC (sequence operation function), capable of simple logic programming to reduce external PLC I/O points
  4. Speed response up to 50Hz, suitable for high-precision tension, Spindel, winding and positioning applications

Kommunikation & Erweiterung

Standard RS485 (Modbus RTU)

Optionale Kommunikationskarten: CC-Link, CC-Link IE Field, Profinet, Profibus-DP, DeviceNet, usw.

Terminals: Digitale Eingänge, Relaisausgänge, open-collector outputs, AM analog voltage monitor, CA analog current monitor

Optionen: Operation panel, braking resistor FR-ABR, EMV-Filter, Gleichstromreaktor, encoder interface card

Typische Anwendungsszenarien (High Search Keywords)

Spindelantrieb, Kran, Winde, extruder, centrifuge, Lüfter & Wasserpumpe, Förderband, Spannungskontrolle, Verpackungsmaschinen, air compressor. The A800 series is positioned as a high-performance heavy-duty general inverter, superior to F800 for loads requiring fast dynamic response.

Umweltspezifikationen

Betriebstemperatur: -10℃~+50℃ (no icing); SLD mode upper limit +40℃

Lagertemperatur: -20℃~+65℃

Luftfeuchtigkeit: Max 95%RH, nicht kondensierend; altitude ≤1000m (derating required above 1000m)

Ersatz & Migration Notes

  1. Ersatz des Vorgängermodells: FR-A740-18.5K upgraded to this model; mounting dimensions and terminal definitions differ, parameters cannot be copied directly and motor auto-tuning must be re-performed
  2. Japanese `-1` vs domestic `-2-60`: Same hardware core, different firmware/standards, nameplate and factory preset parameters. Cannot be interchanged for procurement; region code must be distinguished during ordering
  3. Inländische alternative Referenz: Innovation MD880, Infineon platform high-performance inverters

Quick Reference for Common Faults

E.OC1: Überstrom während der Beschleunigung; E.OC2: Overcurrent at constant speed; E.OC3: Overcurrent during deceleration

E.OV: Überspannung im DC-Bus (high inertia loads require braking resistor)

E.THT: Inverter heatsink overheat (Lüfterausfall, blocked cooling duct)

E.THM: Motor electronic thermal overload

Auswahltipps

Shock loads & frequent start-stop → Use HD mode, it is recommended to select one higher capacity grade

Stable loads such as fans and pumps → Use LD/SLD for higher available motor power

High inertia shutdown → Braking resistor mandatory; 18.5kW unit has built-in braking transistor, no separate braking unit needed

Anwendungsgebiete von Mitsubishi FR-A840-18.5K-1 (A800 18.5kW 400V Class)

The FR-A840 is a high-performance heavy-duty vector inverter. Featuring high low-speed torque, schnelle Reaktion, support for torque/tension control and built-in braking transistor, it is ideal for heavy impact, Spannungskontrolle, spindle and lifting applications, and also supports energy-saving retrofit for fans and pumps.

  1. Crane & Hebezeuge (HD Heavy Duty Mode Preferred)

Gantry crane, overhead crane, small winch, AS/RS stacker, hoist

Merkmale: Hohes Drehmoment bei niedriger Drehzahl, anti-sway control, load holding for heavy weights, high inertia load, häufiges Start-Stopp; 18.5kW built-in braking transistor realizes fast braking with braking resistor

Application keywords: Crane, Winde, stacker, Heben, anti-sway

  1. Web Tension Control Industry (Wicklung & Entspannen)

Papierherstellung, Film, Vliesstoff, adhesive tape, Draht & cable drawing, printing machine, schlittern

Supports sensorless tension control, dancer roller feedback, Synchronisierung der Liniengeschwindigkeit, reduces web tension fluctuation and ensures uniform winding quality

Application keywords: Wicklung, entspannen, Schlitzen, Beschichtung, wire drawing, Drucken, Spannungskontrolle

  1. Werkzeugmaschine & Verarbeitungsausrüstung

CNC machine spindle, grinder, Fräsmaschine, stone cutting machine, Graviermaschine

Wide speed range, schnelle Reaktion, supports asynchronous and PM motor drive; closed-loop vector available with FR-A8AP encoder card for high-precision spindle speed regulation

Application keywords: Machine spindle, grinding machine, high-speed cutting

  1. Extrusion & Rubber/Plastics Machinery

Plastic extruder, rubber extruder, Pelletierer, internal mixer

Large load fluctuation, high starting torque requirement, stable screw speed control to stabilize extrusion pressure and improve product consistency

  1. Fördern & Logistikautomatisierung

Belt conveyor, roller conveyor, automated warehouse, sorting line, heavy-duty pallet conveyor

Multi-drive synchronous control, soft start to reduce mechanical shock; supports PM permanent magnet motor energy-saving solution

Application keywords: Heavy-duty conveyor, Rollenlinie, Logistiksortierung

  1. General Fluid Equipment (Energy-saving Retrofit, LD/SLD Light Duty Mode)

Großer Ventilator, process water pump, air compressor, central air conditioning circulating pump

PID constant pressure/flow control, optimized excitation for energy saving; suitable for energy-saving retrofit of constant torque / variable torque loads

Notiz: F800 series is preferred for fans and pumps; A800 advantage is versatile capability for heavy-duty applications

  1. Other Heavy Industry Applications

Press machine, auxiliary drive for shield machine, mixer, centrifuge, marine deck auxiliary machinery (with filter to meet class society certification)

Heavy-duty host for food packaging, large mixing equipment

Auswahl & Anwendungsschwerpunkte

  1. Shock loads, Heben, Extrusion, Wicklung: HD heavy duty mode, 180% Überlastung für 60s
  2. Stable fan/pump loads: LD/SLD light duty mode for energy saving priority
  3. High inertia shutdown (Winde, Wicklung): External braking resistor required, braking transistor built-in
  4. Japanese FR-A840-18.5K-1 shares identical hardware with China domestic model but differs in factory preset parameters and standards; distinguish region version for project selection.
  5. FR-A840 (3-Phase 400V, Japanese domestic suffix -1, FR-A840-18.5K-1 listed here)

Power Model List (ND rated motor power)

  1. FR-A840-0.4K-1
  2. FR-A840-0.75K-1
  3. FR-A840-1.5K-1
  4. FR-A840-2.2K-1
  5. FR-A840-3.7K-1
  6. FR-A840-5.5K-1
  7. FR-A840-7.5K-1
  8. FR-A840-11K-1
  9. FR-A840-15K-1
  10. FR-A840-18.5K-1 (Ihr Modell)
  11. FR-A840-22K-1
  12. FR-A840-30K-1
  13. FR-A840-37K-1
  14. FR-A840-45K-1
  15. FR-A840-55K-1
  16. FR-A840-75K-1
  17. FR-A840-90K-1
  18. FR-A840-110K-1
  19. FR-A840-132K-1
  20. FR-A840-160K-1
  21. FR-A840-185K-1
  22. FR-A840-220K-1
  23. FR-A840-250K-1
  24. FR-A840-280K-1

Corresponding China Domestic Models (Suffix -2-60, current code type)

LeistungInländisches ModellAktueller Code
0.4KFR-A840-00023-2-6023
0.75KFR-A840-00038-2-6038
1.5KFR-A840-00052-2-6052
2.2KFR-A840-00083-2-6083
3.7KFR-A840-00126-2-60126
5.5KFR-A840-00170-2-60170
7.5KFR-A840-00250-2-60250
11KFR-A840-00310-2-60310
15KFR-A840-00380-2-60380
18.5KFR-A840-00470-2-60470
22KFR-A840-00620-2-60620
30KFR-A840-00770-2-60770
37KFR-A840-00930-2-60930
45KFR-A840-01160-2-601160
55KFR-A840-01800-2-601800
75KFR-A840-02160-2-602160
90KFR-A840-02600-2-602600
110KFR-A840-03250-2-603250
132KFR-A840-03610-2-603610
160KFR-A840-04320-2-604320
185KFR-A840-04810-2-604810
220KFR-A840-05470-2-605470
250KFR-A840-06100-2-606100
280KFR-A840-06830-2-606830
  1. Other A800 Series Models (Full Product Line)
  2. FR-A820 (3-phase 200V class): 0.4K~90K, Suffix -1 (japanisch) / -2-60 (China)
  3. FR-A840 (3-Phase 400V, main model as listed above): 0.4K~280K
  4. FR-A842 (High power split type, 400V): 315K~500K (separate rectifier + inverter unit)
  5. FR-A846 (Dust-proof 400V): 0.4K~132K, enhanced cabinet dust resistance
  6. FR-A840M (Module type 400V): 160K, 200K, common DC bus dedicated
  7. Derivative suffixes:

E: Global general version

GF: Built-in CC-Link IE Field

GN: Built-in CC-Link

CRN: Class certified marine model

III. Wichtige Anmerkungen

  1. Suffix-Erklärung: -1 = Japanese domestic unit; -2-60 = China mainland unit. Hardware identical, factory parameters and safety standards differ; cannot be directly interchanged for purchase.
  2. Models 18.5kW and below have built-in braking transistor; 22kW and above high power models require separate braking unit.
  3. HD mode for heavy-duty applications; LD/SLD light duty for fans & pumps with derating operation.

Mitsubishi FR-A840-18.5K-1 Installation & Commissioning Full Tutorial

Model description: FR-A840-18.5K-1, 3-Phase 400V, 18.5kW, eingebauter Bremstransistor (P/+, PR terminals for braking resistor); Japanese version, hardware identical to China FR-A840-00470-2-60, different factory default parameters.

⚠️ Safety Precaution: All wiring work must be performed with power off; capacitors retain high voltage after main power cut-off. Warte wenigstens 10 minutes and confirm charge lamp is OFF before opening cover.

  1. Mechanische Installation (Cabinet Mounting IP20)
  2. Umgebungsanforderungen für die Installation

Montageausrichtung: Vertical wall mount, Horizontale oder umgekehrte Montage verboten; fixed on non-combustible rigid steel plate

Umgebungstemperatur: Operation -10℃~+50℃ (no icing); SLD light duty ≤40℃; Schrankbelüftung erforderlich

Umfeld: Von Staub fernhalten, Ölnebel, ätzendes Gas, direkte Sonneneinstrahlung; humidity ≤95%RH non-condensing; altitude ≤1000m, derating required above 1000m

Schrankabstand: ≥100mm free space top & Boden zur Wärmeableitung; multiple units can be mounted side-by-side at ambient temperature, ≥50mm gap recommended for high-temperature environments

  1. Installationsschritte
  2. Unpacking inspection: Check housing integrity, fan intact, operation panel and terminal cover complete; verify nameplate model FR-A840-18.5K-1
  3. Position and drill holes, fasten with M6/M8 screws, tighten torque per manual to prevent vibration loosening
  4. Remove front cover for main circuit and control circuit wiring; reinstall cover after wiring completion
  5. Install optional parts (falls erforderlich): Bremswiderstand, EMV-Filter, Gleichstromreaktor, FR-A8AP encoder card (for closed-loop vector)
  6. Elektrische Verkabelung (Key Terminals)

Hauptstromkreisklemmen

R/L1, S/L2, T/L3: 3-phase 380~500V power input

U, V, W: Anschluss an 3-Phasen-Asynchronmotor; Do NOT install capacitor or surge absorber on inverter output side; this will damage inverter

P/+, PR: Braking resistor terminals (eingebauter Bremstransistor); remove PR-PX jumper before connecting braking resistor; braking resistor mandatory for winch, winding and high inertia loads

Ground terminal: Reliable earth connection required, earth resistance ≤10Ω; separate grounding for inverter and motor to reduce interference

Control Circuit Terminals (Häufig verwendet)

STF: Forward run; STR: Reverse run; SD: Digital input common terminal (sink type default)

RH/RM/RL: Multi-speed terminals

AU: Current input selection; Terminal 4: 4~20mA; Terminal 2: 0~10V voltage reference

BIN: Analog voltage monitor; CA: Analog current monitor

ABC: Fault relay output (B-C closed, A-C open during fault)

Verkabelungsspezifikation: Main power cable recommended 10mm²; shielded motor cable preferred; separate routing for power cable and control cable; shielded control cable with single-end grounding.

III. Inspektion vor dem Einschalten (Mandatory to Prevent Damage)

  1. Use multimeter in power-off state: No short circuit between R/S/T, U/V/W; no short circuit between P/+ and PR; no short circuit to ground
  2. Confirm motor wiring correct, mechanical load decoupled (Decouple mechanical load for first trial run, test motor without load)
  3. Verify braking resistor wiring without short circuit; all terminal screws tightened
  4. Confirm input power AC380~480V, keine Überspannung
  5. Einschalten & Basic Parameter Setting (PU Panel Commissioning)

Panel keys: MODUS, SET confirm, ESC exit, PU/EXT toggle, Knopfverstellung; PU = panel control; EXT = external terminal control

Step1: Einschalten, parameter reset (optional for new unit; recommended for used unit or motor replacement)

Enter parameter, set Pr.ALLC=1 for all parameter clear; power cycle to restore factory settings

Step2: Basic motor nameplate parameters (Core for vector control, must be filled)

Parameter-Nr.ParameternameWert (from motor nameplate)
Pr.80Nennleistung des Motors18.5 (kW)
Pr.81Nennspannung des Motors380/400V
Pr.82MotornennstromMotor nameplate rated current
Pr.83Nennfrequenz des Motors50Hz
Pr.84Nenndrehzahl des MotorsNameplate speed
Pr.9Electronic thermal overload protection currentMotornennstrom

Step3: Operation Mode Pr.79 (Am häufigsten)

Pr.79=0: PU/EXT switchable (Werkseinstellung)

Pr.79=1: PU panel mode, start/stop and frequency set via panel, for commissioning

Pr.79=2: External terminal mode, STF/STR start-stop, potentiometer /4-20mA frequency reference, normal field operation

Pr.79=3: Terminal start, panel knob frequency setting (combined mode)

Step4: Auswahl des Steuermodus (A800 core)

Pr.800=0: V/F-Steuerung (Fans, Pumps, simple conveyor)

Pr.800=20: Sensorlose Vektorsteuerung (asynchronous motor), recommended for crane, extruder, Wicklung, high low-speed torque

Pr.800=30: Closed-loop vector (FR-A8AP encoder card required for motor with encoder)

Schritt 5: Beschleunigung / Deceleration, Frequency Limit

Pr.0: Torque boost; normally not increased under vector control

Pr.1: Upper frequency limit; Pr.2: Lower frequency limit

Pr.7: Beschleunigungszeit; Pr.8: Verzögerungszeit; extend deceleration time for high inertia loads and use braking resistor

  1. Motor Auto-Tuning (Mandatory for Vector Control, Kritischer Schritt)

Two auto-tuning types: Static auto-tuning (Motor steht) and Rotational auto-tuning (motor rotating, höhere Genauigkeit)

✅ Empfohlen: Perform Rotational auto-tuning with load decoupled

  1. Set Pr.96=11 (Rotational auto-tuning for asynchronous motor), press SET
  2. Panel shows “READY”, press FWD start, inverter excites motor automatically, motor runs at low speed
  3. Process lasts dozens of seconds, panel displays END after completion → auto-tuning successful
  4. If ERR displayed: Check motor wiring, nameplate parameters, motor jamming, re-run auto-tuning

Static auto-tuning (when load cannot be decoupled): Pr.96=10; accuracy lower than rotational tuning

  1. No-load Trial Run (PU Mode)
  2. Pr.79=1, PU mode, confirm mechanical no-load, personnel keep clear of transmission mechanism
  3. Set target frequency (e.g.10Hz), press FWD forward run
  4. Monitor: Motor rotation direction, aktuell, Vibration, Lärm; check output frequency & current on panel
  5. Reverse test: REV; stop by STOP
  6. Wrong rotation direction: Power off and swap U & V motor leads; Do NOT swap input R/S/T

Normal no-load current is 30%~60% of motor rated current; stop immediately if abnormal current occurs

Vii. Loaded Commissioning (Switch to External Mode)

  1. Wire external terminals: STF-SD (forward switch), potentiometer to Terminal2 & 5 for 0~10V frequency reference
  2. Pr.79=2, switch to EXT external mode
  3. Low frequency trial run (5~10Hz) under load, monitor torque, current and alarms
  4. Gradually increase frequency and observe:

Heavy-duty applications (Winde, extruder): Enable HD heavy duty mode, 180% overload 60s

Fans & Pumps: LD/SLD light duty mode

  1. Tune acceleration/deceleration time and braking duty ratio; fine-tune tension parameters for tension control applications

VIII. Communication Commissioning (RS485/CC-Link/Profinet, Optional)

  1. Built-in RS485: Modbus RTU, set station address, Baudrate, parity bit
  2. Communication option cards (FR-A8NP Profinet, FR-A8NC CC-Link): Install when power off, configure parameters, communication address and parameter mapping
  3. Common Commissioning Alarm Troubleshooting

E.OC1: Überstrom während der Beschleunigung; motor short circuit, mechanischer Stau, zu kurze Beschleunigungszeit

E.OV: Überspannung im DC-Bus; high inertia shutdown, increase braking resistor capacity or extend deceleration time

E.THT: Wechselrichter überhitzt; fan damage, verstopfter Kühlluftkanal

E.UVT: Unterspannung; input phase loss, large voltage drop

E.ALM: Motorüberlastung; incorrect Pr.9 thermal setting, mechanical binding

  1. Handover & Dokumentation
  2. Upload parameters to operation panel for backup (parameter copy), save parameter document
  3. Record auto-tuning result, motor parameters and alarm history
  4. Ziehen Sie alle Klemmen wieder fest, reinstall cover, clean cabinet debris

Wichtige Hinweise

  1. Japanese FR-A840-18.5K-1 has different safety specs and factory preset settings vs China -2-60 Modell. Do not directly download Chinese project parameter files; re-run motor auto-tuning.
  2. 18.5kW unit has built-in braking transistor, but braking resistor needs separate selection, cannot be omitted.
  3. Motor auto-tuning is mandatory for vector control, otherwise low-speed torque is insufficient and trip may occur.

Vorher:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen