NXC-09M10-Z DC24V is a mini DC coil contactor from CHINT Kunlun NXC series, featuring 3P, 9A, 1 NO auxiliary contact, and DC24V control. It is used in DC control circuits, SPS-Steuerungssysteme, and automated equipment.
- Modellerklärung (Precise Breakdown)
NXC: CHINT Kunlun series contactor
09: Rated operational current 9A (AC-3)
M: Miniature type (kompakte Größe)
10: Auxiliary contact-1 NO (1 Normalerweise geöffnet)
Z: DC coil
DC24V: Coil voltage 24V DC
- Wichtige technische Parameter
Item Specification
Series NXC (Kunlun Miniature)
Poles 3P (3-Pole)
Hauptkontakte 3 NEIN (3 Normalerweise geöffnet)
Hilfskontakt 1 NEIN (1 Normalerweise geöffnet)
Nennstrom (Dh) 9A (AC-3, 380V)
Coil voltage DC24V
Rated insulation voltage 690V
Conventional thermal current 10A
Operating frequency 1200 Operationen/Stunde
Mechanical endurance 10 Millionen Operationen
Electrical endurance 1 Millionen Operationen
Mounting 35mm DIN rail / screw mounting
Abmessungen (B×H×T) 45.5×82×58mm
Weight Approx. 0.25kg
Certifications CCC, CE
- Main Features
Miniature size: Spart Platz im Schrank, ideal for compact distribution boards
DC coil (DC24V): Suitable for PLCs, DC-Steuerkreise, und Automatisierungssysteme
Low power consumption, lange lebensdauer: Energy-saving coil, good voltage fluctuation resistance
Flame-retardant housing: UL94 V0 flame rating, sicher und zuverlässig
Matchable: Can be used with NXR series thermal relays to form motor protection circuits
- Anwendungen
PLC output control (24V DC systems)
Control of small motors, Fans, Pumps
Automated equipment, Werkzeugmaschinen, Verpackungsmaschinen
DC-Steuerkreise, solenoid valves, Beleuchtung
Compact installation in power distribution cabinets, control cabinets
- Alternative / Similar Models in the Same Series
NXC-09M01-Z DC24V: 3P 9A, 1 NC (1 Normalerweise geschlossen)
NXC-09M/22-Z DC24V: 3P 9A, 2 NEIN + 2 NC
NXC-06M10-Z DC24V: 3P 6A, 1 NEIN
NXC-12M10-Z DC24V: 3P 12A, 1 NEIN
Legacy replacement: NC1-0910Z DC24V
The CHINT NXC series (Kunlun series) is an upgraded version of CJX2, covering 6A~630A, and is divided into standard type (N), miniature type (M), DC type (Z), 4P, usw. Below is the complete model list, naming rules, order numbers, and cross-brand replacements with Schneider / Siemens / ABB.
- Complete NXC Naming Rule
NXC-[Aktuell]-[Auxiliary]-[Typ]-[Spule]
NXC: Kunlun series contactor
06/09/12/18/25/32/38/40/50/65/80/95/100…630: Nennstrom (AC-3) in amps
M: Miniature type (compact, 06~12A)
10/01/11/22: Hilfskontakte
10 = 1 NEIN
01 = 1 NC
11 = 1 NEIN + 1 NC (Standard)
22 = 2 NEIN + 2 NC
Z: DC coil
Coil voltage: AC24V/36V/110V/220V/380V; DC24V/48V/110V/220V
Beispiele:
NXC-09M10-Z DC24V: Miniature, 9A, 1 NEIN, DC24V
NXC-1811 AC220V: Standard, 18A, 1 NO+1 NC, AC220V
- Complete NXC Model List (Mainstream)
1) Miniature Type (M: 06~12A, compact)
NXC-06M10 / 06M01 / 06M11 / 06M22 (AC/DC)
NXC-09M10 / 09M01 / 09M11 / 09M22 (AC/DC)
NXC-12M10 / 12M01 / 12M11 / 12M22 (AC/DC)
DC models: Suffixed with -Z (z.B. NXC-09M10-Z DC24V)
2) Standardtyp (N: 18~100A, general-purpose)
NXC-1810 / 1801 / 1811 / 1822
NXC-2510 / 2501 / 2511 / 2522
NXC-3210 / 3201 / 3211 / 3222
NXC-3810 / 3801 / 3811 / 3822
NXC-4010 / 4001 / 4011 / 4022
NXC-5010 / 5001 / 5011 / 5022
NXC-6510 / 6501 / 6511 / 6522
NXC-8010 / 8001 / 8011 / 8022
NXC-9510 / 9501 / 9511 / 9522
NXC-10010 / 10001 / 10011 / 10022
3) High Current (120~630A)
NXC-120 / 160 / 225 / 265 / 330 / 400 / 500 / 630
Auxiliary: Standard 2 NEIN + 2 NC
Spule: AC/DC universal (220V/380V)
4) 4-Pole (4P: 06M~12M)
NXC-06MD4 (4P, DC type)
NXC-09MD4
NXC-12MD4
- CHINT NXC Official Order Numbers (Partial)
NXC-06M10 AC220V: 710010100000627
NXC-09M10 AC220V: 710010100000491
NXC-09M10-Z DC24V: 710010100001024
NXC-12M10 AC220V: 710010100000499
NXC-1811 AC220V: 710010100000631
NXC-2511 AC220V: 710010100000578
NXC-3211 AC220V: 710010100000283
NXC-3811 AC220V: 710010100000610
NXC-5011 AC220V: 710010100000277
NXC-6511 AC220V: 710010100000278
NXC-8011 AC220V: 710010100000279
NXC-9511 AC220V: 710010100000280
- Cross-Brand Replacement Cross-Reference (NXC ↔ Schneider / Siemens / ABB)
1) Miniature DC (Beispiel: NXC-09M10-Z DC24V)
CHINT: NXC-09M10-Z DC24V
Schneider: LC1-D09BDC (DC24V) / Bestell-Nr.: LC1D09BD
Siemens: 3RT6016-1BB41 (DC24V)
ABB: A9-30-10 DC24V / Bestell-Nr.: 1SBL141001R8110
2) Full Model Cross-Reference (3P 1NO+1NC AC220V)
| CHINT NXC | Schneider LC1D | Siemens 3RT/3TF | ABB A Series |
| NXC-0611 | LC1-D0610M5C | 3RT6015-1AN21 | A6-30-10 |
| NXC-0911 | LC1-D0911M5C | 3RT6016-1AN21 | A9-30-11 |
| NXC-1211 | LC1-D1211M5C | 3RT6017-1AN21 | A12-30-11 |
| NXC-1811 | LC1-D1811M5C | 3RT6018-1AN21 | A16-30-11 / A26 |
| NXC-2511 | LC1-D2511M5C | 3RT6021-1AN21 | A26-30-11 / A30 |
| NXC-3211 | LC1-D3211M5C | 3RT6023-1AN21 | A30-30-11 / A40 |
| NXC-3811 | LC1-D3811M5C | 3RT6024-1AN21 | A40-30-11 |
| NXC-4011 | LC1-D4011M5C | 3RT6025-1AN21 | A50-30-11 |
| NXC-5011 | LC1-D5011M5C | 3RT6026-1AN21 | A63-30-11 |
| NXC-6511 | LC1-D6511M5C | 3RT6035-1AN21 | A75-30-11 |
| NXC-8011 | LC1-D8011M5C | 3RT6045-1AN21 | A90-30-11 |
| NXC-9511 | LC1-D9511M5C | 3RT6046-1AN21 | A110-30-11 |
- Selection Guidelines
Miniature M: Begrenzter Schrankraum, PLC DC control (DC24V)
Standard N: General motors, Fans, Pumps, Stromverteilung
DC type Z: Solenoid valves, Gleichstromkreise, Automatisierungsgeräte
Hilfskontakte: 10(1NEIN), 01(1NC), 11(1NO+1NC), 22(2NO+2NC)
Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien


















NH42-63-318x560.png)