PNOZ-X2.8P-777301 PILZ Safety Relay

PNOZ-X2.8P-777301-PILZ is the most widely used dual-channel safety relay from Pilz’s PNOZ X product line. Its core advantages cover wide 24V AC/DC operating voltage, 3NO+1NC contact configuration, high safety rating of SIL 3 / PL e, and ultra-fast response within ≤50ms. It is extensively deployed for various industrial safety monitoring applications. Thanks to hardwired design, ...

  • Produktdetails

PNOZ-X2.8P-777301-PILZ is the most widely used dual-channel safety relay from Pilz’s PNOZ X product line. Its core advantages cover wide 24V AC/DC operating voltage, 3NO+1NC contact configuration, high safety rating of SIL 3 / PL e, and ultra-fast response within ≤50ms. It is extensively deployed for various industrial safety monitoring applications. Thanks to hardwired design, it delivers superior reliability over software-based solutions under high-vibration and severe EMI conditions, making it an optimal choice for industrial automation safety protection.

  1. Aufschlüsselung des Modellcodes
CodesegmentDefinitionDetaillierte Beschreibung
PNOSISPräfix der ProduktserieIdentifier for Pilz core safety relay product range
XSeriencodeBasic standalone safety relay of PNOZ X series, operable without extension modules
2.8Functional code“2” stands for dual-channel monitoring; “8” denotes automatic / monitored start mode with 3 safety outputs plus 1 Hilfsausgang
PBeendigungstypScrew terminal version; Push-in indicates spring-cage pluggable terminals, unmarked for standard terminals
777301Order numberUnique global part number for purchasing and inventory management
PILZMarkennamePilz GmbH & Co. KG, Deutschland
  1. Grundlegende technische Spezifikationen
ParameterkategorieSpezifikationBemerkungen
General Data
ProdukttypDual-channel safety relayKonform mit EN ISO 13849-1 (PL e) & IN 62061 (SIL 3)
Bewertetes Angebot24V AC/DC (±15 %)Wide-range input compatible with standard industrial power supplies
Dimension94×22.5×121mm (H×B×T)22.5mm standard width for compact cabinet layout
Montage35mm DIN-Schiene (IN 60715)Vertikale Installation, Anzugsdrehmoment: 0.5~0.8Nm
Eingabemerkmale
Input Circuits2 independent dual-channel inputs (S11-S12/S52, S21-S22)24In DC, 30mA input, compatible with PNP sensors
EingabefunktionOptional cross-contact short-circuit detectionEnabled by short-circuiting S11-S12; disabled by short-circuiting S21-S22
Ausgabeeigenschaften
Sicherheitsausgänge3 Normalerweise geöffnet (NEIN) contacts with redundant dual-contact series designRedundant structure for guaranteed safe cut-off
Hilfsausgang1 Normalerweise geschlossen (NC) KontaktNur zur Statusanzeige, NOT permitted in safety circuits
KontaktbewertungAC1:240V/6A; DC1:24V/6AAgCuNi silver-copper-nickel contact material for arc oxidation resistance
AC15:230V/5A; DC13:24V/5A
Leistungsparameter
Ansprechzeit≤50ms (input to output); reset time ≤100msFast safety cut-off for high-speed machinery
StromverbrauchMax.100mALow-power design for energy saving
UmgebungstemperaturBetrieb: -10°C ~ +55°C; Lagerung: -35°C ~ +70°CSuitable for harsh industrial ambient conditions
Schutz vor EindringenIP20 (main body), IP40 (terminal area)Must be installed inside control cabinet ≥IP54
ZertifizierungenCE, CCC, UL, RoHSGlobal market access certifications

III. Full Range Model List (Core PNOZ X2 Series)

ModellBestell-Nr.VersorgungsspannungAusgabekonfigurationStart ModeTerminaltyp
PNOZ X2.8P77730124V AC/DC3NO+1NCAutomatisch / MonitoredSchrauben
PNOZ X2.877730024V AC/DC3NO+1NCAutomatisch / MonitoredStandard
PNOZ X2.8P PI77730224V AC/DC3NO+1NCAutomatisch / MonitoredPlug-in
PNOZ X2.7P77731124~240V AC/DC3NO+1NCAutomatisch / MonitoredSchrauben
PNOZ X2.777731024~240V AC/DC3NO+1NCAutomatisch / MonitoredStandard
PNOZ X2.10P77732124In DC2NO+1NCManueller ResetSchrauben
PNOZ X2.11P77733124In DC3NO+1NCManueller ResetSchrauben
  1. Cross-Brand Equivalent Replacement Table
MarkeAlternative PartHauptunterschiedeAnwendungsbereich
SchneiderZelio SR2B121BDSingle-channel, 2NO+1NC, 24VDC onlyLow-risk applications with limited budget
Siemens3SK1111-1AB30Zweikanalig,3NO+1NC,24V AC/DCFull drop-in replacement, SIL3 compliant
OmronG9SA-321-T075Zweikanalig,3NO+1NC,24V AC/DCMatched for Japanese-built equipment, kostengünstig
ABBMSR125TPZweikanalig,3NO+1NC,24V AC/DCHeavy-duty machinery with superior anti-vibration performance
Pilz UpgradePNOZ X2.7P (777311)Breite Spannung:24~240V AC/DCGlobal projects with varying supply voltages
  1. Anwendungsumgebung & Branchenfälle

Empfohlene Anwendungen

  1. Machinery Safety Monitoring: Emergency stop pushbuttons, safety door interlocks, safety light curtains, two-hand control stations
  2. Automobilbau: Schweißroboter, coating production lines, lithium battery equipment interlock control
  3. Electronics Assembly: SMT-Bestückungsmaschinen, AOI inspection equipment, laser cutter safety circuits
  4. Verpackungsmaschinen: Hochgeschwindigkeitsverpackungslinien, palletizing robots, over-temperature protection for heat-sealing devices
  5. Logistics Automation: Stacker cranes, AGVs, conveyor safety door & E-stop systems

Non-Recommended Applications

Safety systems requiring complex logic operations (PNOZmulti modular safety controller recommended)

Extreme high-vibration environments (>10G): extra vibration dampening required

Unprotected outdoor mounting (only IP20 body protection)

Typische Anwendungsfälle

Case1: Lithium Battery Aging Room Safety Control for Automotive Industry

Funktionen: Access door interlock, emergency cut-off on over-temperature, fire protection linkage

Konfiguration: PNOZ X2.8P(777301)+safety door switch+temperature sensor+E-stop button

Ergebnis: PL e safety level achieved to prevent thermal runaway of lithium cells

Case2: Safety Circuit Retrofit for Laser Cutting Machine

Original Issue: Distributed safety PLC I/O triggered false shutdown twice in three years due to EMI interference

Lösung: Replace with hardwired safety circuit using PNOZ X2.8P

Ergebnis: Zero breakdown over 5 Jahre, response optimized ≤50ms, Wartungskosten um reduziert 60%

  1. Auswahltipps & Kurzreferenzregeln

Quick Selection Formula

24V AC/DC X2.8, dual-channel with three NO & one NC<Br>

Schraubklemme 777301, automatic start with top safety grade<Br>

Not-Aus, Lichtvorhang & Sicherheitstür, certified SIL3 & PL e<Br>

DIN rail mounting saves cabinet space, fits all industrial sites

Kurzreferenzregeln

  1. Model Memorization: PNOZ X2.8P = Dual-channel + Mode8 + P=screw terminals
  2. Bestellcode:777301 = standard baseline part of Pilz X2 family
  3. Kernspezifikationen:24V AC/DC,3NO+1NC,≤50ms response,SIL3/PL e
  4. Terminal Wiring Rules:

Short S11-S12: Activate contact short-circuit detection

Short S21-S22: Deactivate contact short-circuit detection

Short S12-S34: Enable automatic start mode

Short S52-S11: Enable automatic reset function

VII. Installation & Wartungsrichtlinien

Installationsspezifikationen

  1. Mount vertically inside control cabinet with terminals facing upward for natural convection cooling
  2. Maintain ≥50mm clearance from heat-generating components, ≥30mm from cabinet inner walls
  3. Separate wiring of safety circuits and power circuits; route crossing wires at 90° to reduce EMI coupling
  4. Install 10A fuse in series ahead of output contacts for contact protection

Common Troubleshooting Guide

FehlerphänomenGrundursacheRemedial Action
Betriebsanzeige aus1. No power supply or reversed polarity1. Verify A1/A2 wiring
2. Input voltage out of tolerance2. Confirm stable 24V AC/DC supply
Safety outputs fail to close1. Open input circuit1. Check continuity of S11-S12/S21-S22
2. Incorrect start circuit configuration2. Confirm jumper status of S12-S34
Contact ablation/burning1. Overloaded output rating1. Upgrade to higher-rated relay
2. Missing snubber for inductive loads2. Fit freewheeling diode(Gleichstrom) or varistor(Wechselstrom) in parallel
Unexpected false tripping1. Electromagnetic interference on input lines1. Apply shielded cable with proper grounding
2. Misconfigured short-circuit detection2. Adjust S11-S12/S21-S22 jumper setup

VIII. Compliance bei Lufttransporten & Certification Details

UN-Nummer: Keine eingebaute Lithiumbatterie, classified as non-dangerous goods

Transport Category: Stückgut, acceptable for air, sea and land freight

CE Compliance: Complies with EN 60947-5-1/-2 und EN ISO 13849-1

HS-Code: 85364900 (Other electrical relays)