(Modicon X80 Platform Hardened 8-channel Isolated High-speed Analog Input Module), including model breakdown, core parameters, interface/configuration, and application scenarios Model and Positioning Model: BMXAMI0810H; belongs to Modicon X80 I/O platform, compatible with Modicon M580, M340 PAC/PLC Suffix H = Hardened type. Compared with the standard BMXAMI0810, it features wider temperature range, higher vibration resistance and ...

  • Produktdetails

(Modicon X80 Platform Hardened 8-channel Isolated High-speed Analog Input Module), including model breakdown, core parameters, interface/configuration, and application scenarios

  1. Model and Positioning

Modell: BMXAMI0810H; belongs to Modicon X80 I/O platform, compatible with Modicon M580, M340 PAC/PLC

Suffix H = Hardened type. Compared with the standard BMXAMI0810, it features wider temperature range, higher vibration resistance and stronger EMI immunity, geeignet für raue Industrieumgebungen.

Funktion: 8-channel fully isolated voltage/current analog input, high-speed conversion, flexible signal type and range configuration via software + DIP switches.

  1. Core Technical Specifications
ParameterkategorieDetaillierte Spezifikationen
Input Channels8 Kanäle, per-channel independent isolation
SignaltypenStromspannung (±10V, 0–10V, ±5V, 0–5V); Aktuell (4–20mA, 0–20mA)
Auflösung15 Bits + Vorzeichenbit (equivalent to 16-bit accuracy)
KonvertierungsgeschwindigkeitHigh-speed mode, short single-channel conversion time, supports synchronous batch acquisition
Genauigkeit±0.1% of full scale (typical), low drift design
Power Supply24In DC, power consumption 1.54W
BetriebstemperaturGehärteter Typ: -25°C bis +70°C (standard version: 0°C~60°C)
SchutzgradIP20 (must be installed in control cabinet)
MontageDIN rail mounting (standard 35mm)
ZertifizierungenCE, UL, CSA, ATEX, IECEx (suitable for hazardous areas)
Wiring AccessoriesBMXFTB2800 (screw terminal), BMXFTB2820 (spring terminal), BMXFTW308S/508S flying leads, BMXFTA150/300 (with ABE7 base)
  1. Key Features and Advantages
  2. Full-channel electrical isolation: Effectively suppresses common-mode interference and surges in industrial sites, ensuring stable data acquisition.
  3. Hardened wide-temperature design: Adapts to extreme temperature and vibration environments such as metallurgy, Bergbau, and outdoor cabinets.
  4. High-speed conversion + flexible filtering: Filter parameters can be adjusted via software, balancing dynamic response and data smoothing.
  5. Seamless integration with M580/M340: Unified backplane bus of X80 platform, supports hot-swappable maintenance (system configuration required).
  6. Multiple wiring schemes: Optional terminal blocks / flying leads / base cables to adapt to different cabinet wiring habits.
  7. Typische Anwendungsszenarien
  8. Process control: Chemical, petroleum, water treatment; acquisition of pressure, flow, Ebene, pH value (4–20mA/0–10V transmitter signals).
  9. Metallurgie / Paper making: High-temperature workshops, production line monitoring; wide-temperature tolerance, strong anti-EMI capability.
  10. Energy industry: Wind power, Photovoltaik, Umspannwerke; acquisition of voltage, aktuell, Leistung; stable operation in outdoor / box-type substations.
  11. Heavy machinery / Marine: High-vibration, large temperature-fluctuation scenarios such as offshore platforms and port machinery.
  12. Smart manufacturing lines: Equipment status monitoring, sensor data acquisition; works with M580 redundant systems to improve reliability.
  13. Model Differentiation and Alternatives
  14. BMXAMI0810 vs BMXAMI0810H: The former is standard version (0°C~60°C); the latter H-type hardened wide-temperature (-25°C~70°C), with stronger shock and vibration resistance.
  15. Equivalent alternative models:

Siemens: 6ES7531-7KF00-0AB0 (ET 200SP AI module)

ABB: AI890 8-channel isolated analog input

Rockwell: 1756-IF8H (ControlLogix high-temperature analog module)

  1. Selection and Notes
  2. Confirm on-site temperature range: If below 0°C or above 60°C, H-type must be selected.
  3. Confirm wiring method: Terminal blocks suit fixed cabinets; flying leads suit narrow spaces or frequent replacement.
  4. System redundancy requirements: In M580 redundant systems, modules must be configured in pairs with redundant communication enabled.
  5. Grounding and shielding: Full shielding of analog signal cables, single-point grounding to avoid interference.

Schneider Electric BMX Series (Modicon X80)

Full Model List & Alternative Product Manual

  1. BMX Series Overview and Coding Rules

Schneider BMX Series are core I/O modules of the Modicon X80 platform, compatible with M580, M340 PAC/PLC. They cover digital, analog, Kommunikation, power supply, motion control and other categories. Suffix H means hardened type (wide temperature -25°C~+70°C, higher vibration & EMI resistance).

Model Coding Rule (BMXABCDEFG)

SegmentBedeutungBeispiel
BMXFixed prefix (Modicon X80 series)BMX
AModule typeD=Digital, A=Analog, N=Communication, C=Power, M=Motion
BSubtypeDI=Digital Input, DO=Digital Output, AI=Analog Input, AO=Analog Output, NO=Ethernet
CDEFChannel count / specification0810=8-channel/standard, 0410=4-channel/high-speed
G/HVersionH=Hardened, Default=Standard (0°C~60°C)
  1. Complete BMX Series Model List (By Type)

2.1 Digital Input Modules (BMXDDI/BMXDAI)

ModellSpezifikationAnwendungHardened Version
BMXDDI160216-ch 24V DC, sink, non-isolatedGeneral industrial signal acquisitionBMXDDI1602H
BMXDDI3202K32-ch 24V DC, source, isolatedHigh-density I/O, centralized cabinet acquisitionBMXDDI3202KH
BMXDDI6402K64-ch 24V DC, source, dual 40-pinLarge production lines, robot workstationsBMXDDI6402KH
BMXDAI08148-ch 100-120V AC, isolatedMotor control loops, high-voltage equipment monitoringBMXDAI0814H
BMXDAI160416-ch 100-120V AC, isolatedFactory power systems, HVAC controlBMXDAI1604H

2.2 Digital Output Modules (BMXDDO/BMXDAO)

ModellSpezifikationAnwendungHardened Version
BMXDDO160216-ch 24V DC, 0.5A, non-isolatedSolenoid valves, indicator controlBMXDDO1602H
BMXDDO3202K32-ch 24V DC, 0.5A, isolatedDistributed control for large equipmentBMXDDO3202KH
BMXDDO6402KC64-ch 24V DC, 0.5A, dual 40-pinAutomotive production lines, logistics sortingBMXDDO6402KCH
BMXDAO160516-ch 100-240V AC, triacHeating systems, lighting controlBMXDAO1605H
BMXDDO161016-ch 24V DC, 2A, high-powerKleine Motoren, valve actuatorsBMXDDO1610H

2.3 Analog Input Modules (BMXAMI/BMXART)

ModellSpezifikationGenauigkeitHardened Version
BMXAMI04104-ch voltage/current, isolated, high-speed15 Bits + VorzeichenbitBMXAMI0410H
BMXAMI08108-ch voltage/current, isolated, high-speed15 Bits + VorzeichenbitBMXAMI0810H (Popular)
BMXART04144-ch RTD/TC, isolated16-bit, dedicated for temperatureBMXART0414H
BMXART08148-ch RTD/TC, isolated16-bit, temperature patrolBMXART0814H

2.4 Analog Output Modules (BMXAMO)

ModellSpezifikationGenauigkeitHardened Version
BMXAMO04104-ch voltage/current, isolated, high-speed15 Bits + VorzeichenbitBMXAMO0410H
BMXAMO08028-ch voltage/current, isolated, Standard14 Bits + VorzeichenbitBMXAMO0802H

2.5 Mixed I/O Modules (BMXAMM)

ModellSpezifikationAnwendung
BMXAMM06004AI + 2AO, mixed analog, isolatedSmall process control, equipment integrated control
BMXAMM10008AI + 2AO, mixed analog, isolatedMedium process monitoring, building automation

2.6 Kommunikationsmodule (BMXNOE/BMXNOM/BMXCRA)

ModellFunktionInterfaceKompatibilität
BMXNOE0100Ethernet interface, TCP/IP1×RJ45M340/M580 local
BMXNOM0200Modbus RTU/ASCII Master2×RS485Instrument networking, inverter control
BMXCRA31210PROFIBUS-DP Master1×DP portSiemens interconnection, process control
BMXETH0100Dual Ethernet, redundancy2×RJ45M580 redundant systems, critical control

2.7 Power Supply Modules (BMXCPS)

ModellInput / OutputLeistungMerkmale
BMXCPS2000100-240V AC/DC → 24V DC20WKompakt, for M340
BMXCPS3500100-240V AC/DC → 24V DC35WStandard type, for M580
BMXCPS402285-264V AC → 24V DC40WWide input voltage, industrial grid compatible

2.8 Motion Control Modules (BMXMSP)

ModellFunktionAxesKompatibilität
BMXMSP02002-axis PTO + 4DI/2DO auxiliary, 24In DC2 AchsenStepper/servo control, positioning systems
BMXMSP04004-axis PTO + 8DI/4DO auxiliary, 24In DC4 AchsenMulti-axis linkage, robot control
  1. BMX Series vs. Other Brands Alternative Models (with Order Numbers)
Schneider ModelSiemens AlternativeOrder NumberKey Matching Points
BMXDDI3202KH6ES7131-6BH01-0BA06ES7131-6BH01-0BA032DI/24V DC, isolated, source
BMXAMI0810H6ES7531-7KF00-0AB06ES7531-7KF00-0AB08AI/isolated/high-speed, 16bit
BMXAMO0410H6ES7532-5HF00-0AB06ES7532-5HF00-0AB04AO/isolated/high-speed, 16bit
BMXCRA312106ES7138-4HA00-0AB06ES7138-4HA00-0AB0PROFIBUS-DP Master, M580 compatible

3.2 ABB Alternatives (AC500/S700 Series)

Schneider ModelABB AlternativeOrder NumberKey Matching Points
BMXDDI1602HAI8103BSE018100R116DI/24V DC, isolated, hardened
BMXAMI0810HAI8903BSE018190R18AI/isolated/wide-temp, 16bit
BMXAMO0410HAO8903BSE018200R14AO/isolated/wide-temp, 16bit
BMXNOE0100CM5793BSE018151R1Ethernet interface, TCP/IP, AC500 compatible

3.3 Rockwell Alternatives (ControlLogix)

Schneider ModelRockwell AlternativeOrder NumberKey Matching Points
BMXDDI3202KH1756-IB321756-IB3232DI/24V DC, source, isolated
BMXAMI0810H1756-IF8H1756-IF8H8AI/isolated/high-temp, 16bit
BMXAMO0410H1756-OF41756-OF44AO/isolated/high-speed, 16bit
BMXCRA312101756-DP11756-DP1PROFIBUS-DP Master, ControlLogix compatible
  1. Key Points for Selection and Replacement

4.1 Core Matching Dimensions (Must Check for Replacement)

DimensionPassender StandardNotizen
Channel count / typeExactly the same (z.B., 8AI→8AI, 32DI→32DI)Avoid insufficient or redundant channels
Electrical isolationSame level (per-channel / group isolation)Isolated type is mandatory for industrial sites
Temperature rangeHardened → Hardened (-25°C~+70°C)No downgrading for outdoor / metallurgy / Bergbau
Communication protocolCompatible with original system (z.B., PROFINET/Modbus)Bus compatibility test required for non-Schneider modules
MontagemethodeSame rail / backplane adaptationSpecial adaptation required for M580 redundant systems

4.2 Replacement Implementation Recommendations

  1. Schneider→Schneider: Prioritize same-series upgrades (z.B., BMXAMI0810→BMXAMI0810H). No program modification needed; only firmware version check required.
  2. Cross-brand replacement:

Perform signal compatibility test before replacement (voltage/current range, Ansprechzeit).

In M580 redundant systems, alternative modules must support hot-swap and redundant communication.

Analog modules require accuracy deviation calibration (±0.1% F.S. as industrial standard).

  1. Cost optimization: Domestic alternatives such as Advantech, NORCO are available, with similar performance and 30%-50% lower price.
  2. Schnellauswahltabelle (Popular Models)
AnwendungPreferred Schneider ModelSiemens AlternativeABB AlternativeRockwell Alternative
Process control (4-20mA acquisition)BMXAMI0810H6ES7531-7KF00-0AB0AI8901756-IF8H
Factory automation (24V DC I/O)BMXDDI3202KH/BMXDDO3202KH6ES7131-6BH01-0BA0 / 6ES7132-6BH01-0BA0AI810/AO8101756-IB32/1756-OB32
Temperature monitoring (TC/RTD)BMXART0814H6ES7531-7PF00-0AB0AI8951756-IT6
Instrument networking (Modbus RTU)BMXNOM02006ES7138-4CA01-0AA0CM5781756-MODULE