Part Number Breakdown & Product Positioning EA9RN3C3230CA is a 3‑pole integrated Residual Current Circuit Breaker with Overcurrent protection (RCBO) from Schneider Electric’s Easy9 series (EA9R). It provides threefold protection: Überlast, short‑circuit, and earth‑leakage protection, suitable for final distribution systems in residential, kommerziell, and light industrial applications. Part Segment Description EA9R Easy9 series RCBO N Standard ...

  • Produktdetails

Part Number Breakdown & Produktpositionierung

EA9RN3C3230CA is a 3‑pole integrated Residual Current Circuit Breaker with Overcurrent protection (RCBO) from Schneider Electric’s Easy9 series (EA9R).

It provides threefold protection: Überlast, short‑circuit, and earth‑leakage protection, suitable for final distribution systems in residential, kommerziell, and light industrial applications.

Part SegmentBeschreibung
EA9REasy9 series RCBO
NStandard breaking capacity (6 kA)
3Number of poles (3P), three‑phase protection
CTripping curve type, für allgemeine Belastungen (Beleuchtung, Steckdosen)
32Nennstrom: 32 A
30Residual current sensitivity: 30 mA, for personal electric shock protection
CAType‑A leakage protection, detects AC and pulsating DC leakage for modern electronic loads
  1. Key Electrical Specifications
ParameterSpezifikation
Rated operational voltage230/400 V AC, three‑phase four‑wire system
Bemessungsisolationsspannung600 V AC
Rated impulse withstand voltage4 kV
Nennstrom (In)32 A
AuslösekurveTyp C, magnetic tripping range: 5–10 × In
Bruchkapazität (Icn)6 kA (at 400 V)
Residual current sensitivity (IΔn)30 mA, fast operation (≤ 0.1 s)
Leakage protection typeType‑A, detects AC and pulsating DC leakage
Rated frequency50/60 Hz
IsolationsfunktionComplies with IEC standards, provides isolation
  1. Merkmale & Benefits
  2. Threefold protection: Überlast, short‑circuit, and earth‑leakage protection for comprehensive electrical safety.
  3. Type‑A leakage detection: Suitable for pulsating DC leakage from modern electronic equipment (switching power supplies, inverters, usw.).
  4. Clear status indication: Handle and contact position indication for quick status judgment.
  5. Reliable mechanical performance: Mechanical life ≥ 20,000 operations; electrical life ≥ 5,000 operations.
  6. Einfache Installation: Standard 35 mm DIN‑rail mounting with locking clamps.
  7. Eco‑friendly: Mercury‑free, complies with EU RoHS and China RoHS; part of Schneider Green Premium.
  8. Wide operating temperature: -25 °C to +60 °C.
  9. Installation & Maintenance Guide

Installationsanforderungen

Montage: Standard 35 mm DIN‑rail; width = 3 Module (54 mm); height = 117 mm.

Wiring capacity:

Top: M5 terminal, max 25 mm² flexible cable

Bottom: M6.5 terminal, max 25 mm² flexible / 35 mm² semi‑rigid / solid cable

Environment: Dust‑free, dry, non‑corrosive, low vibration; installation altitude ≤ 2000 m.

Sicherheit: Must be installed by a qualified electrician in accordance with GB 16917 and IEC 61009.

Wartung

  1. Operate ON/OFF monthly to check mechanical function.
  2. Test leakage protection quarterly using the TEST button.
  3. Nach Fehlerauslösung, resolve the cause before resetting.
  4. Avoid frequent unnecessary operation.
  5. Clean with dry cloth only when power is off; no chemical cleaners.
  6. Ersatz & Upgrade Options

Same‑Series Replacements

ModellUnterschiedAnwendung
EA9RN3C3230CRNew marking, identical performanceStock replacement
EA9RN3C3230CNEWNew naming, same performanceProduct iteration
EA9RN3C32100CA100 mA sensitivity, for equipment protectionMotoren, Pumps

Upgraded Models (Higher Performance)

SerieTypisches ModellWichtigste Verbesserungen
A9 ProA9P323230Smart monitoring, Fernbedienung, fault diagnostics
Acti9 iIDA9R26332Selective protection, 10 kA breaking capacity, longer life

Cross‑Brand Compatible Replacements

MarkeErsatzmodellKompatibilität
Siemens5SU9356‑3CR32Identical electrical & mounting dimensions
ABBGS201 A‑C32/0.03Equivalent protection, Type‑A, 32 A/30 mA, DIN‑rail
ChintNXBLE‑32‑3P‑C32/0.03ACost‑effective direct replacement
  1. Anwendungen & Selection Tips

Typische Anwendungen

Three‑phase power circuits in residential/commercial buildings (AC units, Pumps, Fans)

Final distribution for light industrial equipment (Werkzeugmaschinen, Verpackungsmaschinen)

Input protection for PV inverters, UPS, and power electronics

Hospitals, Rechenzentren, and high‑safety locations

Selection Guidelines

  1. Verify voltage (230/400 V) and frequency (50/60 Hz).
  2. Choose tripping curve: Type C for general loads.
  3. Nennstrom: 32 A suitable for three‑phase loads ≤ 7 kW.
  4. Use Type‑A for systems with electronic equipment.
  5. 6 kA breaking capacity suits most final circuits; upgrade to 10 kA near transformers.
  6. Approvals & Einhaltung

Standards: GB 16917 / IEC 61009

Certifications: CCC, CE

Environment: EU RoHS, China RoHS, REACH compliant

Garantie: 3‑year official Schneider warranty under normal use

EA9RN3C3230CA is a reliable, easy‑to‑install 3‑pole, 32 A, 30 mA, Type‑A RCBO from the Schneider Easy9 series. It provides comprehensive protection for final distribution applications. Suppliers can recommend same‑series replacements, upgrade to A9 Pro / Acti9 iID, or offer cross‑brand alternatives based on project requirements.

Cross‑Brand & Equivalent Model List for Schneider EA9RN3C3230CA

  1. Full List of Equivalent Models

(EA9RN series, 3P, 32 A, 30 mA, Type‑A RCBO)

ModellBeschreibungKey SpecsNotizen
EA9RN3C3230CAStandard model3P, C32A, 30mA, Type‑A, 6DieBase version
EA9RN3C3230CRNew marking3P, C32A, 30mA, Type‑A, 6DieLabel update only
EA9RN3C3230CNEWNew naming3P, C32A, 30mA, Type‑A, 6DiePerformance unchanged
EA9RN3C3230CARRegional variant3P, C32A, 30mA, Type‑A, 6DieRegional supply

Other Current Ratings (3P, 30 mA, Type‑A)

ModellNennstromAnwendung
EA9RN3C1030CA10 ASmall three‑phase loads
EA9RN3C1630CA16 ASmall/medium equipment
EA9RN3C2030CA20 AGeneral power circuits
EA9RN3C2530CA25 AMedium power loads
EA9RN3C4030CA40 AHeavy three‑phase loads
EA9RN3C5030CA50 AHigh‑power equipment
EA9RN3C6330CA63 AMain switches / large machinery
  1. Cross‑Brand Cross‑Reference

(3P, 32 A, 30 mA, Type‑A RCBO, direct interchangeable)

MarkeModellNennstromSensitivityBreakingKompatibilität
Siemens5SU9356‑3CR3232 A30 mA6 kAFully compatible
Siemens5SU9356‑3CR32NEW32 A30 mA6 kANew version
ABBGS201 A‑C32/0.0332 A30 mA6 kADirekter Ersatz
ABBS201‑C32 A‑0.0332 A30 mA6 kACompact design
ChintNXBLE‑32‑3P‑C32/0.03A32 A30 mA6 kACost‑effective
NaderNDBLE‑32‑3P‑C32/0.03A32 A30 mA6 kAReliable domestic
LeckerCDL7‑32‑3P‑C32/0.03A32 A30 mA6 kAEconomic option
Changshu-SchalterCH3L‑32‑3P‑C32/0.03A32 A30 mA6 kAIndustrial grade
  1. Full Naming Convention for EA9RN Series
SegmentBedeutungOptionen
EA9RSerieEasy9 RCBO
NBruchkapazitätN = 6 kA
3Polen1P, 2P, 3P, 4P, 1P+N
CAuslösekurveC = general; D = motor / heavy load
32Nennstrom6, 10, 16, 20, 25, 32, 40, 50, 63 A
30Leakage sensitivity30 mA (personal); 100 mA (equipment)
CALeakage typeCA = Type‑A; AC = Type‑AC
  1. Auswahlnotizen
  2. Leakage type: Use Type‑A for systems with inverters, switching power supplies.
  3. Bruchkapazität: 6 kA for most final circuits; 10 kA near transformers.
  4. Abmessungen: 35 mm DIN‑rail; 3P = 3 Module (54 mm).
  5. Zertifizierung: Use CCC‑approved products in China.
  6. Brand consistency: Prefer same brand in one system to avoid unwanted tripping.
  7. Ersatz & Upgrade-Pfad

Upgrades Within Schneider

SerieModellImprovementsAnwendung
Acti9 iIDA9R26332Selective protection, 10 kACommercial & industrial
A9 ProA9P323230Smart monitoring, FernbedienungSmart buildings, Rechenzentren

Cross‑Series Drop‑In Replacements

EA9RN3C3230CA ↔ EA9RN3C3230CR (new marking)

For higher breaking: EA9RH3C3230CA (10 kA), same dimensions

The Schneider EA9RN3C3230CA is a robust 3P, 32 A, 30 mA, Type‑A RCBO. Equivalent models include EA9RN3C3230CR and EA9RN3C3230CNEW.

Top cross‑brand direct replacements:

Siemens 5SU9356‑3CR32, ABB GS201 A‑C32/0.03, Chint NXBLE‑32‑3P‑C32/0.03A.