Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

Schneider Electric NSX250N‑3P‑160A - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Leistungsschalter/

Schneider Electric NSX250N‑3P‑160A

This is a Schneider Electric ComPacT NSX series molded case circuit breaker (MCCB) for power distribution protection. New standard order number: C25N3TM160 Obsolete old order number: LV431832 Compliant with IEC 60947‑2 and GB/T 14048.2 Standards. Basic Rated Core Parameters Item Value Type Low‑voltage MCCB for power distribution protection Frame rating 250A Poles 3P (3 Stangen, ...

  • Produktdetails

This is a Schneider Electric ComPacT NSX series Kompaktleistungsschalter (MCCB) for power distribution protection.

New standard order number: C25N3TM160

Obsolete old order number: LV431832

Compliant with IEC 60947‑2 and GB/T 14048.2 Standards.

  1. Basic Rated Core Parameters
ArtikelWert
TypLow‑voltage MCCB for power distribution protection
Frame rating250A
Poles3P (3 Stangen, all protected)
Rated current In160A (continuous at 40℃)
Rated operational voltage Ue690V AC 50/60Hz, suitable for 380V/400V/415V systems
Rated insulation voltage Ui800V und
Rated impulse withstand voltage Uimp8kV
Frequenz50/60Hz
Utilization categoryType A (no short‑time delay, general distribution)
Isolation functionCertified isolating function per IEC 60947‑2
  1. Short‑Circuit Breaking Capacity
System VoltageRated ultimate shortircuit breaking capacity IcuRated service shortircuit breaking capacity Ics
415V und50Die50Die (100% Icu, reusable after breaking)
500V und36Die36Die
690V und10Die10Die

Rated short‑time withstand current Icw (1S): 12kA at 415V AC

  1. TMD Thermal‑Magnetic Release Characteristics

Standard TMD thermal‑magnetic release, LI protection (long‑time overload + instantaneous short‑circuit).

  1. Long‑time overload thermal protection

Ir setting range: 0.7–1×In (112A–160A)

Merkmal: 120–400s at 1.5×Ir; ≤15s at 6×Ir (standard inverse time)

  1. Short‑circuit instantaneous magnetic protection

Instantaneous current Ii: fixed at 1250A

Operating time: ≤20ms

  1. Mechanical & Installation Parameters
ArtikelWert
Abmessungen (W×H×D)105mm × 161mm × 86mm
Standard mounting centersVertical 125mm × Horizontal 35mm
MontageBehoben, front connected; horizontal/vertical, kein Derating
Wiring capacityUp to 70mm² copper cable / busbar
Mechanical endurance20,000 Operationen
Electrical endurance10,000 operations at 440V AC, In
Ingress protectionIP40 (body), IP54 (panel‑mounted)
Impact resistanceIK07
Net weightApprox. 2.4kg
  1. Environmental & Compliance Parameters

Ambient temperature: -25℃ ~ +70℃; no derating below 40℃

Höhe: 0–2000m without derating

Pollution degree: 3

Overvoltage category: II

Certifications: CCC, CE, EAC, Marine, usw.

Accessory slots: 5 standard slots for auxiliary, alarm, shunt, undervoltage release, usw.

  1. Expansion & Compatibility

Can be fitted with Vigi earth‑leakage modules

Compatible with motor operators for remote control

Can add interlock, position indicator, padlock devices

Top/bottom feed both allowed without performance derating

Replacement & Auswahlnotizen

  1. Old type LV431832 is discontinued; use C25N3TM160 instead.
  2. For electronic release (adjustable short delay / earth fault), upgrade to NSX250N with MicroLogic (2.2/5.0).
  3. Breaking ratings: H (70Die), S (100Die), based on short‑circuit calculation.
  4. Konkurrenten: ABB Tmax T2, Siemens 3VT250, suitable for cross‑brand replacement.

NSX250N‑3P‑160A Direct Replacement Solutions

Core Matching Rules (100% match required)

Frame rating: 250A (do NOT downgrade to 160A frame)

Poles: 3P

Nennstrom: 160A

Bruchkapazität: ≥50kA at 415V AC

Release type: thermal‑magnetic (LI characteristic)

Montage: fixed front connection, matching panel holes

  1. Recommended Replacements

Scenario 1: Import Brand Direct Replacement

ABB Tmax XT3N250 TMD160/1600 FF 3P

Order No.: 1SDA068266R1

Match: 100%

Frame 250A, 3P, 160A, TMG thermal‑magnetic

Icu=50kA, Ics=50kA at 415V AC

Identical dimensions and mounting holes

Full accessory compatibility

Anwendung: foreign‑funded plants, export equipment, on‑site repair

Siemens 3VC250N TMA160 3P

Order No.: 3VC2316‑2DA33‑0AA0

Match: 98%

Frame 250A, 3P, 160A, TMA thermal‑magnetic

50kA at 415V AC

Highly compatible dimensions

Anwendung: Siemens low‑voltage systems

Scenario 2: Domestic High‑Cost‑Performance Replacement

Changshu Switch CM3‑250H/3300 160A

Match: 99%

Frame 250A, 3P, 160A, distribution type thermal‑magnetic

Icu=50kA at 415V AC

Compliant with IEC 60947‑2 / GB 14048.2

Anwendung: industrial, building distribution, domestic projects

Chint NM8‑250N/3P 160A

Match: 95%

Frame 250A, 3P, 160A, thermal‑magnetic

50kA at 415V AC

Anwendung: civil construction, general distribution

  1. Abmessungen & Parameters Comparison
ModellAbmessungen (W×H×D)Mounting CentersIcu (415V)ReleaseFrame
NSX250N‑3P‑160A105×161×86mm125mm×35mm50DieTMD250A
ABB XT3N250 3P 160A105×161×86mm125mm×35mm50DieTMG250A
Siemens 3VC250N 3P 160A105×160×85mm125mm×35mm50DieTMA250A
CM3‑250H 3P 160A108×162×86mm125mm×35mm50DieThermal‑magnetic250A

> Notiz: ABB XT3N250 matches dimensions and holes 100% – best direct replacement.

  1. Safety Rules for Replacement
  2. No frame downgrade: Do NOT use 160A frame breakers (z.B., ABB T2N, NSX160).
  3. Breaking capacity ≥50kA: Do NOT use 36kA / 25kA models.
  4. Release matching: Use distribution‑type thermal‑magnetic only.
  5. Accessory compatibility: Match auxiliary, shunt, Unterspannung, earth‑leakage modules.
  6. Final Selection Guide

Direct replacement, import, no cabinet modification: ABB XT3N250 TMD160/1600 FF 3P

New project, domestic approval, cost‑effective: Changshu CM3‑250H/3300 160A

Siemens system replacement: Siemens 3VC250N TMA160 3P