ABB-MCCB-XT6S-3P-800

Interpretation des Modellcodes (ABB SACE Tmax XT Series) Code Segment Description Details ABB‑MCCB Brand & Type ABB Molded Case Circuit Breaker XT6S Series & Rating XT6 series (800A frame), S = standard breaking capacity (22Die). Also available: L = high (50Die), H = ultra‑high (65Die) 3P Number of Poles 3‑pole, für den dreiphasigen Stromkreisschutz 800 ...

  • Produktdetails

Interpretation des Modellcodes (ABB SACE Tmax XT Series)

CodesegmentBeschreibungEinzelheiten
ABB‑MCCBMarke & TypABB Molded Case Circuit Breaker
XT6SSerie & BewertungXT6 series (800A frame), S = standard breaking capacity (22Die). Also available: L = high (50Die), H = ultra‑high (65Die)
3PAnzahl der Pole3-Pole, für den dreiphasigen Stromkreisschutz
800NennstromRated operational current 800A; adjustable range varies by trip unit type
Complete Model Examples1SDA100740R1XT6S 800 TMA 800‑8000 3p F F (Thermisch-magnetischer Auslöser)XT6S 800 EkipDip LS/I 800A 3p F F (Elektronische Reise)
1SDA100741R1
  1. Technische Kernparameter (XT6S 800A 3P Standard Configuration)
ParameterkategorieSpezifikationBemerkungen
Rahmenstrom800ASuitable for rated current settings from 630A to 800A
Nennbetriebsspannung690V und, 750In DCEntspricht IEC 60947-2
Bemessungsisolationsspannung1000VEnsures safe insulation performance
Bewertete Stoßspannungsfestigkeit8kVSurge voltage immunity
BruchkapazitätIcu = 22kA @ 400VType S standard breaking capacity, for general industrial environments
Ics = 11kA @ 400V (50% Icu)
MontageartBehoben (F) / Plug-in (P) / Drawer (D)Standard: Behoben (F); other types available on request
VerbindungstypFrontanschluss (F) / Anschluss hinten (R)Standard: Frontanschluss (F), easy for panel installation and maintenance
Schutz vor EindringenIP30Complies with EN 60529; dust‑protected, finger‑protected
Betriebstemperatur-25℃ ~ +70℃Standard range; Über 40℃ ist eine Leistungsreduzierung erforderlich
  1. Auslösertypen & Schutzfunktionen (Key Configuration Differences)
  2. Thermisch-magnetische Auslöseeinheit (TMA)

Schutzfunktionen: Überlastschutz (L) + instantaneous short-circuit protection (ICH)

Current Settings: Overload 0.8-1.0×In (640-800A), instantaneous 4000-8000A (5-10×In)

Anwendung: Simple power distribution systems, no complex settings required, kostengünstig

Komplettes Modell: XT6S 800 TMA 800-8000 3p F F (1SDA100740R1)

  1. Electronic Trip Unit (EkipDip LS/I)

Schutzfunktionen: Adjustable overload (L) + short-time delay short-circuit (S) + sofortiger Kurzschluss (ICH) Schutz

Current Settings: L = 0.4-1.0×In (320-800A), S = 1.0-10×In (800-8000A), I = 5-10×In (4000-8000A)

Additional Features: Supports remote control, fault indication, communication expansion (with Ekip Com module)

Anwendung: Complex power distribution systems requiring precise protection settings; suitable for motors and transformers

Komplettes Modell: XT6S 800 EkipDip LS/I 800A 3p F F (1SDA100741R1)

  1. Hauptmerkmale & Vorteile (XT6S Series)
  2. Modularer Aufbau: Interchangeable thermal-magnetic / electronic trip units; 3 breaking capacity levels for flexible system matching
  3. Installation Flexibility: Behoben, Plug-in, and drawer mounting; front/rear connection options to save panel space
  4. Sicherheit & Zuverlässigkeit: UL 100% rated, IEC certified; mechanical life 20,000 Operationen, elektrische Lebensdauer 5,000 Operationen
  5. Smart Expansion: Electronic trip versions support Ekip Com modules for Profinet, EtherNet/IP and other protocols
  6. Eco-Design: RoHS-konform, frei von Schadstoffen, high recyclability
  7. Einfache Wartung: Modular components enable quick replacement and reduced downtime
  8. Complete Model Matrix (XT6S 800A 3P Full Configurations)
ReisetypBruchkapazitätKomplettes Modell (Bestellcode)
Thermal‑Magnetic (TMA)S (22Die)1SDA100740R1XT6S 800 TMA 800‑8000 3p F F
Thermal‑Magnetic (TMA)S (22Die)1SDA102846R1XT6S 800 TMA In=800A 3p F F UL (UL certified)
Elektronisch (EkipDip)S (22Die)1SDA100741R1XT6S 800 EkipDip LS/I 800A 3p F F
Elektronisch (EkipM)S (22Die)1SDA100747R1XT6S 800 EkipM Dip I 800A 3p F F (Motorschutz)
Elektronisch (EkipG)S (22Die)1SDA102847R1XT6S 800 EkipG Dip LS/I 800A 3p F F (Advanced protection)
  1. Anwendungen & Auswahlempfehlungen

Typische Anwendungen

Main power distribution in industrial plants (secondary protection for 630-800kW transformers)

Große Motorkontrollzentren (MCC), protecting 75-90kW three-phase motors (parallel groups)

UPS output protection in data centers

Main distribution boards in commercial buildings

Inverter output protection in PV power stations

Auswahlrichtlinien

  1. Anpassung der Schaltleistung: Select S/L/H versions based on system short-circuit current
  2. Trip Selection: Thermisch-magnetisch (TMA) for simple distribution; elektronisch (Ekip) for complex systems
  3. Montageart: Fixed for new installations; plug-in/drawer for frequent maintenance
  4. Nennstromeinstellung: Match total load current; recommended 1.1-1.2× load current
  5. Umweltanpassung: No derating at -10℃~+40℃; derate 1% per °C above 40℃
  6. Alternative Modelle & Brand Comparison (Marktreferenz 2026)

ABB Same-Series Alternatives

Alternatives ModellHauptunterschiedAnwendung
XT6L 800 3PHigher breaking capacity 50kASystems with high short‑circuit current
XT6H 800 3PUltra‑high breaking capacity 65kAIndustrial busbars, Isc > 50Die
XT6S 630 3PSmaller frame current 630ALoad current ≤ 630A

Andere Markenalternativen

MarkeAlternatives ModellEquivalent Breaking CapacityPreisvergleich
SchneiderNSX630N‑800A 3P25Die (similar to S type)5–8% lower than ABB
Siemens3VA6880‑6EL32‑0AA025Die (similar to S type)Comparable to ABB, richer smart functions
EatonZM800M3‑V080025Die (similar to S type)3–5% lower than ABB
ChintNM1‑800S/330025Die (similar to S type)30–40% lower than ABB, kostengünstig
  1. 2026 Market Price Reference (RMB, 13% VAT included)
KonfigurationPremier Distributor PriceGeneral Distributor PriceStaffelpreis (≥5 units)Bemerkungen
Thermal‑Magnetic (TMA)18,000–22,00016,000–20,00015,000–18,0001SDA100740R1
Elektronisch (EkipDip)22,000–26,00020,000–24,00019,000–22,0001SDA100741R1
Elektronisch (EkipM)24,000–28,00022,000–26,00021,000–24,0001SDA100747R1 (Motorschutz)
Price Factors• Channel: Authorized distributors offer stable pricing; unauthorized channels 10–15% cheaper but no warranty
• Lead time: In stock +3–5%; 4–6 week lead time at better prices
• Services: Installation support +500–1000 RMB; 3‑year extended warranty +8–10%
  1. Installation & Wartungshinweise
  2. Installationsumgebung

Betriebstemperatur: -10℃ ~ +40℃ (derate 1% per °C above 40℃)

Relative Luftfeuchtigkeit: ≤95 %, nicht kondensierend

Höhe: ≤2000m (derate above 2000m)

  1. Verkabelungsspezifikationen

Conductor size: ≥185mm² copper cable for sufficient current carrying capacity

Drehmomentbedarf: Main terminal bolt torque 70Nm for reliable connection

  1. Maintenance Intervals

Routine inspection: Once monthly, check appearance and tightness

Periodic maintenance: Once yearly, clean, test trip functions, verify ON/OFF performance

  1. Selection Summary
  2. Load Evaluation: Select 800A rated current based on total three-phase current, within frame limit
  3. Short-Circuit Analysis: Calculate system short-circuit current to choose S/L/H breaking capacity
  4. Protection Requirements: Thermal-magnetic for basic distribution; electronic for precise protection and monitoring
  5. Installation Conditions: Choose mounting/connection based on panel space and maintenance needs
  6. Budget Consideration: Balance cost and reliability; electronic trip units recommended for critical circuits

ABB MCCB Model List & Bestellcodes

  1. Overview of ABB MCCB Series

ABB molded case circuit breakers mainly include two series: Tmax XT Series (high-end industrial, SACE Tmax XT1-XT7) and Formula Series (wirtschaftlich, Formula A1-A3), covering 16A-1600A for various applications.

  1. Regeln zur Modellbenennung (Tmax XT Series Example)
PositionCodeBeschreibungOptionen
1XT[1–7]Serie & RahmengrößeXT1(160A), XT2(160A), XT3(250A), XT4(250A), XT5(630A), XT6(1000A), XT7(1600A)
2C/N/L/H/MSchaltleistungsklasseC=15kA, N=25kA, L=36/50kA, H=65kA, M=100kA
3NummerRahmenstrom160/250/630/800/1000/1200/1600A
4TMD/TMA/Ekip…ReisetypTMD = Thermal‑magnetic (distribution)
TMA = Thermal‑magnetic (Motor)
EkipDip = Basic electronic
EkipC = Advanced electronic
5Number/RangeNennstrom / Setting Rangez.B. 800‑8000 (thermisch-magnetisch), 800A (elektronisch)
63P/4PPolen3P = Three‑phase, 4P = Three‑phase + N
7F/P/DMontageF=Fixed, P=Plug‑in, D=Drawer
8F/RVerbindungF=Front, R=Rear
91SDA…R1Offizieller BestellcodeABB standard order number
  1. Tmax XT Series (SACE Tmax XT1-XT7) Modellliste & Bestellcodes
  2. XT1 Series (Frame 160A, 16-160A adjustable)
ModellbeispielBestellcodeBruchkapazitätReisetypNennstromPolenMontage/Anschl
XT1C 160 TMD R16‑160 FF 3P1SDA067393R115DieThermisch-magnetisch (dist)16‑160A3PFixed/Front
XT1N 160 TMD R100 FF 4P1SDA067461R125DieThermisch-magnetisch (dist)100A4PFixed/Front
XT1H 160 TMA R125‑1250 FF 3P1SDA067462R165DieThermisch-magnetisch (Motor)125A3PFixed/Front
XT1L 160 EkipDip LS/I R160 FF 3P1SDA067463R150DieElektronisch160A3PFixed/Front
  1. XT2 Series (Frame 160A, Prämie)
ModellbeispielBestellcodeBruchkapazitätReisetypNennstromPolenMontage/Anschl
XT2N 160 TMD R63 FF 3P1SDA100730R125DieThermisch-magnetisch (dist)63A3PFixed/Front
XT2L 160 EkipC LSIG R100 FF 3P1015286950DieAdvanced Electronic100A3PFixed/Front
XT2H 160 EkipM I R125 FF 3P1SDA100735R165DieMotor Electronic125A3PFixed/Front
XT2N 160 TMA R160‑1600 FF 4P1SDA100736R125DieThermisch-magnetisch (Motor)160A4PFixed/Front
  1. XT3 Series (Frame 250A, 16-250A adjustable)
ModellbeispielBestellcodeBruchkapazitätReisetypNennstromPolenMontage/Anschl
XT3N 250 TMD R200 FF 3P1SDA100737R125DieThermisch-magnetisch (dist)200A3PFixed/Front
XT3L 250 EkipDip LS/I R250 FF 3P1SDA100738R150DieBasic Electronic250A3PFixed/Front
XT3H 250 TMA R225‑2250 FF 3P1SDA100739R165DieThermisch-magnetisch (Motor)225A3PFixed/Front
  1. XT4 Series (Frame 250A, Prämie)
ModellbeispielBestellcodeBruchkapazitätReisetypNennstromPolenMontage/Anschl
XT4N 250 TMD R160 FF 3P1SDA100740R125DieThermisch-magnetisch (dist)160A3PFixed/Front
XT4L 250 EkipC LSIG R200 FF 3P1015303750DieAdvanced Electronic200A3PFixed/Front
XT4H 250 EkipM I R250 FF 4P1SDA100742R165DieMotor Electronic250A4PFixed/Front
  1. XT5 Series (Frame 630A, 250-630A adjustable)
ModellbeispielBestellcodeBruchkapazitätReisetypNennstromPolenMontage/Anschl
XT5N 630 TMD R630‑6300 FF 3P1SDA100743R125DieThermisch-magnetisch (dist)630A3PFixed/Front
XT5L 630 EkipDip LS/I R630 FF 3P1SDA100744R150DieBasic Electronic630A3PFixed/Front
XT5H 630 EkipC LSIG R500 FF 3P1SDA100745R165DieAdvanced Electronic500A3PFixed/Front
  1. XT6 Series (Frame 800/1000A, 630-1000A adjustable)
ModellbeispielBestellcodeBruchkapazitätReisetypNennstromPolenMontage/Anschl
XT6S 800 TMA 800‑8000 FF 3P1SDA100740R122DieThermisch-magnetisch (Motor)800A3PFixed/Front
XT6S 800 EkipDip LS/I 800A FF 3P1SDA100741R122DieBasic Electronic800A3PFixed/Front
XT6L 1000 TMD 1000‑10000 FF 3P1SDA100746R150DieThermisch-magnetisch (dist)1000A3PFixed/Front
  1. XT7 Series (Frame 1200/1600A, 1000-1600A adjustable)
ModellbeispielBestellcodeBruchkapazitätReisetypNennstromPolenMontage/Anschl
XT7M 1200 EkipC LSIG 1200A FF 3P1SDA100748R1100DieAdvanced Electronic1200A3PFixed/Front
XT7M 1600 TMD 1600‑16000 FF 3P1SDA100749R1100DieThermisch-magnetisch (dist)1600A3PFixed/Front
  1. Formula Series (Economic, A1-A3) Modellliste & Bestellcodes
  2. A1 Series (Frame 125A, 16-125A adjustable)
ModellbeispielBestellcodeBruchkapazitätReisetypNennstromPolenMontage/Anschl
A1N125 TMF125/1250 FF 3P1011644825DieThermisch-magnetisch (dist)125A3PFixed/Front
A1C125 TMF63/630 FF 4P1011644915DieThermisch-magnetisch (dist)63A4PFixed/Front
  1. A2 Series (Frame 250A, 16-250A adjustable)
ModellbeispielBestellcodeBruchkapazitätReisetypNennstromPolenMontage/Anschl
A2N250 TMF250/2500 FF 3P1011645025DieThermisch-magnetisch (dist)250A3PFixed/Front
A2L250 MA200/2000 FF 3P1011645136DieMagnetisch (Motor)200A3PFixed/Front
  1. A3-Serie (Frame 400A, 250-400A adjustable)
ModellbeispielBestellcodeBruchkapazitätReisetypNennstromPolenMontage/Anschl
A3N400 TMF400/4000 FF 3P1011645225DieThermisch-magnetisch (dist)400A3PFixed/Front
A3L400 TMF315/3150 FF 4P1011645336DieThermisch-magnetisch (dist)315A4PFixed/Front
  1. Special Function Models
Special FunctionCodeExample ModelBestellcodeBeschreibung
DC ApplicationGleichstromXT4L 250 EkipDip DC 200A FF 3P1SDA100750R1For DC circuit protection
Enhanced Environment383XT6S 800 TMA 800‑8000 FF 3P 3831SDA100751R1Operating temp -25℃~+70℃
MotorschutzMA/MXT2N 160 MA100/600‑1400 FF 3P10152868Dedicated motor trip unit
Drawer MountingDXT5N 630 TMD 630‑6300 FD 3P1SDA100752R1Drawer type for easy maintenance
  1. Auswahl & Ordering Guidelines
  2. Bruchkapazität: Select C/N/L/H/M according to system short-circuit current for safe fault interruption
  3. Trip Unit Selection

Verteilung: TMD thermal-magnetic or EkipDip basic electronic

Motorschutz: TMA thermal-magnetic or EkipM dedicated electronic

Complex systems: EkipC advanced electronic with full LSIG protection

  1. Montageart: Behoben (F) lowest cost; Plug-in (P) for easy replacement; Drawer (D) for frequent maintenance
  2. Order Code Verification: ABB official codes start with 1SDA…R1 or 101…; purchase via authorized channels to avoid counterfeits
  3. Quick Selection Chart (By Current Range)
Aktueller BereichEmpfohlene SerieTypisches ModellSample Order Code
16–160AXT1/XT2/A1XT2N 160 TMD R100 FF 3P1SDA100730R1
160–250AXT3/XT4/A2XT4L 250 EkipDip 200A FF 3P1SDA100738R1
250–630AXT5/A3XT5N 630 TMD 630‑6300 FF 3P1SDA100743R1
630–1000AXT6XT6S 800 EkipDip 800A FF 3P1SDA100741R1
1000–1600AXT7XT7M 1200 EkipC 1200A FF 3P1SDA100748R1