Schneider NSYCVF165M230PF Filterlüfter

Model Code Definition Breakdown of NSYCVF165M230PF Code Segment Meaning Description NSY Product series prefix General mark for Schneider ClimaSys cabinet cooling products CV Sub-series ClimaSys CV series standard cabinet filter fan F Product type Fan 165 Air flow rate Rated airflow 165m鲁/h at 50Hz, 193m鲁/h at 60Hz M Mounting type Side mounting on cabinet 230 ...

  • Produktdetails

Modellcode-Definition

Breakdown of NSYCVF165M230PF

CodesegmentBedeutungBeschreibung
NSYProduct series prefixGeneral mark for Schneider ClimaSys cabinet cooling products
CVUnterserieClimaSys CV series standard cabinet filter fan
FProdukttypLüfter
165Air flow rateRated airflow 165m鲁/h at 50Hz, 193m鲁/h at 60Hz
MMontageartSide mounting on cabinet
230Nennspannung230V und
PSchutzkonfigurationEquipped with pre-filter
FAir outlet configurationFitted with front grille
  1. Kernspezifikationsparameter
KategorieTechnischer IndexBemerkungen
Grundparameter
ProdukttypCabinet Filter FanClimaSys CV series, IP54 protection
Air Flow165m³/h (50Hz) / 193m³/h (60Hz)Measured with standard G2 filter
Spannungsbereich175~253V ACCompatible with most 230V power grids worldwide
Nennspannung230V 50/60HzDual frequency compatibility
Elektrische Parameter
Leistung16.3W (50Hz) / 14.3W (60Hz)High energy efficiency
Aktuell0.12A (50Hz) / 0.94A (60Hz)Design mit geringem Stromverbrauch
VerbindungFaston terminal + power cableEinfache Installation
Physical Parameters
External Dimension268×248×104mmHeight×Width×Depth
Cutout Size223×223mmStandard cabinet mounting hole
MaterialAir outlet grille: ASA+PC thermoplasticAnti-aging, grey RAL 7035
Gewicht1.14kgStable installation, low resonance
Leistungsparameter
SchutzklasseIP54Dustproof and splashproof, suitable for outdoor cabinets
Bearing TypeBall bearingLange Lebensdauer, geräuscharm
Noise Level50~51dBQuiet operation, applicable near office areas
Max Static Pressure50Pa (0m³/h)Resists certain air resistance
Umgebungsparameter
Betriebstemperatur-20℃~60℃Wide temperature range for harsh environments
Lagertemperatur-40℃~70℃Reliable transportation and storage
ZertifizierungREACH, RoHSCompliant with environmental standards
  1. Vollständige Modellliste der Serie
ModellAir Flow(m³/h)StromspannungKonfigurationCutout Size(mm)External Size(mm)
NSYCVF38M230PF39230V undGrille + Filter117×117137×137×85
NSYCVF54M230PF54230V undGrille + Filter148×148170×170×92
NSYCVF85M230PF85230V undGrille + Filter170×170190×190×95
NSYCVF165M115PF165/193115V undGrille + Filter223×223268×248×104
NSYCVF165M230PF165/193230V undGrille + Filter223×223268×248×104
NSYCVF165M24DPF165/19324In DCGrille + Filter223×223268×248×104
NSYCVF300M230PF300/350230V undGrille + Filter262×262300×300×110
NSYCVF550M230PF550/650230V undGrille + Filter336×336380×380×120
NSYCVF850M230PF838/980230V undGrille + Filter400×400450×450×130
NSYCVF850M400PF838/980400V undGrille + Filter400×400450×450×130
  1. Cross-brand Replacement Comparison
MarkeModellAir Flow(m³/h)StromspannungSchutzklasseCutout Size(mm)Vorteile des Ersatzes
Rittal323920074/87230V undIP54148×148Tool-free quick installation
Rittal3241700160/190230V undIP54223×223High-efficiency energy saving series
StegoFK 66230165/193230V undIP54223×223Integrated temperature control, intelligent start-stop
Pfannenberg1041230160/190230V undIP54223×223Long filter service life, low maintenance frequency
RS PRO130-853165/193115V undIP54223×223Kostengünstig, sufficient stock
  1. Häufige Fehlerbehebung & Wartung
FehlerphänomenMögliche UrsachenInspektionsschritteMaintenance Solution
Fan not running1. Power disconnected1. Test power voltage1. Reconnect power supply
2. Motor burnout2. Check motor winding resistance2. Replace identical motor
3. Stuck bearing3. Manually rotate fan blade3. Clean and lubricate bearing
4. Control circuit failure4. Inspect loose Faston connector4. Reconnect or replace connector
Reduced airflow1. Clogged filter1. Check filter blockage1. Clean or replace G2 filter
2. Dust accumulated on blades2. Inspect blade cleanliness2. Clean blades with soft brush
3. Unterspannung3. Measure operating voltage3. Adjust voltage to rated value
4. Rückwärtsdrehung4. Verify mounting direction4. Reinstall fan outward air discharge
Abnormal noise1. Worn bearing1. Locate noise source1. Replace bearing or whole fan
2. Unbalanced fan blade2. Check blade deformation and attachments2. Correct balance and clear debris
3. Loose mounting3. Tighten mounting screws3. Fasten all screws
4. Vibration resonance4. Observe cabinet vibration4. Add shock pad or adjust position
Überstromschutz1. Motor short circuit1. Test insulation resistance1. Replace motor
2. Excessive bearing friction2. Check bearing flexibility2. Lubricate or replace bearing
3. Überspannung3. Measure operating voltage3. Restore normal voltage
  1. Anwendungsumgebung & Branchenfälle

Anwendbare Szenarien

  1. Industrielle Automatisierung: Cooling for PLC, inverter and servo drive cabinets
  2. Energiesystem: Heat dissipation for outdoor ring main units, box substations and charging pile control boxes
  3. Telecommunication: Ventilation for base station cabinets, optical distribution boxes and data center server cabinets
  4. Schienenverkehr: Temperature control for signal boxes and converter cabinets
  5. Neue Energie: Cooling for photovoltaic inverters and energy storage control cabinets

Nicht empfohlene Szenarien

  1. Corrosive atmosphere such as chemical and marine environment (anti-corrosion model required)
  2. Heavy dust sites like mines and cement plants (extra pre-filter needed)
  3. Submerged or long-term rain exposure (IP54 only splash-proof)
  4. Fully sealed space without air inlet circulation

Typische Fälle

Automobile Factory: Installed on welding robot cabinets, failure rate reduced by 70% against high temperature

Power Grid Company: Eliminated switch misoperation, equipment service life extended 3 mal

Data Center: Hierarchical cooling with air conditioner, energy consumption cut by 20%

  1. Auswahltipps & Avoidance Guide

Quick Calculation Rule

  1. Airflow demand = Cabinet volume × (8~10) m³/h, suitable for 16~20m³ cabinet
  2. Voltage selection: 230V for general industry, 115V for North America, 24V for DC system
  3. Mounting mark: M=side, MF=top, FB=bottom

Operation Warnings

  1. Inspect and replace G2 filter every 3 months to avoid airflow drop and motor overload
  2. Keep air outlet outward and match air inlet for effective ventilation
  3. Adopt cabinet air conditioner when external temperature is 5℃ higher than internal temperature
  4. Restrict voltage fluctuation within ±10% to guarantee service life
  5. Confirm UL, CE and other certifications for export use
  6. Bestellinformationen

Modell: NSYCVF165M230PF

Bestell-Nr.: NSYCVF165M230PF (Global unified)

Packungsinhalt: 1 axial fan motor, 1 cutting template, 1 pre-filter, 1 air outlet grille, 1 power cable, 2 protective grilles

Delivery Lead Time: 3-5 working days for standard stock items