TE Connectivity RAYCHEM POLT 3XIH1-L12A

3XIH1-L12A is the specification code of TE Connectivity RAYCHEM brand POLT series ≤12kV 3-core heat-shrink power cable terminal. The complete model is usually marked as POLT-12D/3XIH1-L12A. It is suitable for outdoor terminal installation of polymer insulated power cables such as Cross-Linked Polyethylene (XLPE) and Polyethylene (PE), providing reliable electrical insulation and environmental protection.

TE Connectivity RAYCHEM POLT 3XIH1-L12A Heat-Shrink Power Cable Terminal

3XIH1-L12A is the specification code of TE Connectivity RAYCHEM brand POLT series ≤12kV 3-core heat-shrink power cable terminal. The complete model is usually marked as POLT-12D/3XIH1-L12A. It is suitable for outdoor terminal installation of polymer insulated power cables such as Cross-Linked Polyethylene (XLPE) and Polyethylene (PE), providing reliable electrical insulation and environmental protection.

  1. Modellsegmentdefinition
SegmentBedeutungBeschreibung
3Cable Core NumberSpecially for 3-core cables
XInsulation TypeSuitable for polymer insulated cables (XLPE/PE/EPR)
IH1Shield Type & Size SpecificationIH = Copper Wire Shield; 1 = Conductor cross-section 70-120mm²
L12ASpannungsklasse & MontageartL12 = Rated voltage ≤12kV; A = Standard outdoor terminal
POLT-12DProduktseriePOLT = RAYCHEM heat-shrink power cable terminal series; 12D = 12kV outdoor type
  1. Kernspezifikationsparameter
ParameterkategorieTechnischer IndexBemerkungen
Grundlegende Eigenschaften
ProdukttypHeat-shrink Power Cable TerminalAußenaufstellung, polymer insulation system
MarkeTE Connectivity RAYCHEMPOLT series, industry standard product
Applicable Cable Type3-core polymer insulated power cableInsulation material: XLPE, PE, EPR, usw.
Nennspannung≤12kV (U0/U=8.7/15kV)Konform mit IEC 60502-2
Cable Shield TypeCopper Wire ShieldNot applicable for copper tape shielded cables
Leiterspezifikation
Applicable Conductor Section70-120mm²Copper conductor
Conductor Outer Diameter14.0-22.0mmSingle core conductor diameter
Insulation Outer Diameter25.0-35.0mmSingle core insulation diameter
Overall Cable Outer Diameter55.0-75.0mmOuter diameter of complete 3-core cable
Physikalische Eigenschaften
Total Terminal Length450mmStandard outdoor type length
Material CompositionCross-linked Polyolefin Heat-shrink MaterialWeather resistance, UV resistance, aging resistance
FarbeSchwarzIndustrial standard color, anti-UV
InstallationsmethodeHeat shrink installationSpecial heating tool required (≥300℃)
Umgebungsbedingungen
Betriebstemperatur-40°C ~ +90°CGroßer Temperaturbereich, geeignet für raue Umgebungen
Schutz vor EindringenIP68Fully dustproof and waterproof, operable under immersion
Weather ResistanceKonform mit IEC 60811-3-1UV resistance, ozone resistance, chemical corrosion resistance
Elektrische Leistung
Isolationswiderstand≥10¹⁴ΩNormal condition, ensure excellent insulation performance
Spannungsfestigkeit≥45kV/1minBreakdown strength of terminal insulation layer
Partial Discharge≤10pCUnder 1.73U0 voltage, maintain low partial discharge level
Creepage Distance630mmMeet pollution level requirements for 12kV class
  1. Zubehörliste & Montageteile
Teile-Nr.NameFunktionQ’ty
3XIH1-L12A Main KitHeat-shrink Tube AssemblyProvide insulation, sealing and stress control1 Satz
Stress Control TubeNon-linear Heat-shrink TubeUniform electric field distribution, eliminate electric stress concentration3 Stk (1 per core)
Insulation TubeMain Insulation Heat-shrink TubeMain insulation protection1 Stk (für 3 cores)
Sealing TubeWaterproof Sealing Heat-shrink TubeSeal the joint between cable outer sheath and terminal1 Stk
ShedAnti-pollution Flashover Heat-shrink ShedIncrease creepage distance and anti-fouling performance3 Stk
Copper Mesh / Grounding WireShield Grounding WireGround connection for cable shielding layer1 Satz
Filling MasticInsulation Filling MaterialFill gaps between cores, improve insulation performance1 Stk
Cleaning Cloth / SandpaperSurface Treatment ToolsClean cable insulation surface, improve adhesion1 Satz
InstallationshandbuchBedienungsanleitungDetailed installation steps and precautions1 Copy
  1. Wettbewerber & Markenübergreifendes Äquivalent
MarkeErsatzmodellÄhnliche FunktionenUnterschiede
ABBAPIT-12/3-70-12012kV 3-core, 70-120mm, copper wire shieldCold-shrink technology, no heating required, höhere Kosten
3M5623P-1212kV 3-core, 70-120mm, copper wire shieldCold-shrink type, einfache Installation, permanent elasticity
ChangyuanWS-12/3.212kV 3-core, 70-120mm, copper wire shieldHeat-shrink type, kostengünstig, hoher inländischer Marktanteil
WalsinWRS-12/3-70-12012kV 3-core, 70-120mm, copper wire shieldHeat-shrink type, material performance close to RAYCHEM
RAYCHEM Internal Replacement3XIH4-L12A12kV 3-core, 150-240mm, copper wire shieldFor larger conductor section, same terminal length
  1. Auswahlrichtlinien & Ersatzlösungen

5.1 Wichtige Auswahlparameter

ParameterWichtige AuswahlpunkteRecommended Standard
SpannungsanpassungMust match cable rated voltage12kV terminal for 8.7/15kV cable; not for higher voltage class
Core NumberTerminal core number shall be consistent with cable3-core terminal only for 3-core cable, not for single-core or 4-core
Conductor SectionTerminal range must cover cable conductor section70-120mm² terminal applicable to 70、95、120mm² cables
Shield TypeTerminal must match cable shield typeIH for copper wire shield; OH for copper tape shield
InstallationsumgebungL type for outdoor; I type for indoorOutdoor site must adopt L type with sheds

5.2 Ersatzempfehlungen

Mismatched conductor section: Select corresponding range model, z.B. 150-240mm² use 3XIH4-L12A

Different shield type: Copper tape shield cable adopt 3XOH1-L12A

Indoor installation: Choose 3XIH1-I12A (without sheds)

Easier installation requirement: Adopt RAYCHEM cold-shrink terminal (RST series), no heating tool needed

5.3 Vorsichtsmaßnahmen bei der Anwendung

  1. Check cable insulation condition before installation to ensure no damage and no moisture.
  2. Strictly follow installation manual; control heating temperature at 300-350℃ and heating time.
  3. Clean and polish core insulation surface tightly to ensure close fitting of heat-shrink tube.
  4. Reliably connect shielding grounding wire to guarantee electrical safety.
  5. Perform insulation test and partial discharge test after installation; put into operation only after qualified.
  6. Applicable for overhead, Tunnel, cable trench and other outdoor / semi-outdoor occasions; not suitable for underwater use.
  7. Typische Anwendungsszenarien

10kV/12kV distribution line outdoor cable terminals

12kV cable outgoing terminals of substation & switch station

12kV internal power distribution cable terminals for industrial enterprises

12kV cable terminals for new energy projects such as wind power & photovoltaic power generation

12kV cable terminal replacement & renovation of urban power grid