ABB 2UEA001345 Phase Module Kit - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

ABB 2UEA001345 Phase Module Kit - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

NoticiasNoticias comerciales

ABB 2UEA001345 Phase Module Kit

TEJIDO 2UEA001345 (ACS 2040-PMK1000) 4kV Phase Module Kit

ABB 2UEA001345 is a dedicated phase module kit for ACS 2040 series 4kV medium-voltage frequency converters. It serves as the core power unit of the ACS2000 medium-voltage drive system, adopting 3-level IGBT topology. It is applicable to 4kV power grid systems with rated power ranging from 300-1000HP (225-750kilovatios).

Its core strengths include high-reliability design (MTBF>100,000 hours), baja salida de armónicos (compliant with IEEE 519 estándar), modular structure for easy maintenance and replacement, and wide operating temperature range (-10℃ ~ +40℃). It is perfectly suited for general industrial loads such as fans, water pumps and compressors, which can effectively improve system energy efficiency (20%-40% ahorro de energía) and reduce maintenance costs.

  1. Explicación del código del modelo
SecciónCódigoDefinición
Serie de productos2UEASeries code for ABB medium-voltage inverter power modules (2UEA=ACS 2040 serie, 2UEB=ACS 2000 serie)
Part Number1345Unique identification code of phase module kit, corresponding to model ACS 2040-PMK1000
Voltaje aplicable4kVMatches 4000V medium-voltage power grid system
Tipo de productoPMK1000Phase Module Kit, corriente nominal: 1000A
Sistema aplicableACS 2040Compatible with ABB ACS 2040 series medium-voltage inverters

Order Number: 2UEA001345 (Standard single packing)

Modelo a juego: 2UEA001141 (Complementary phase module of the same series)

  1. Main Technical Specifications
CategoríaArtículoParámetroObservaciones
Información básicaTipo de producto4kV Medium Voltage Inverter Phase Module Kit3-level IGBT topology, integrated drive and protection circuits
Applicable InverterACS 2040 Serie (ACS2000 Platform)Compatible with Frame 1 tamaño (300-1000caballos de fuerza)
Tensión nominal4kV (4000V)Rango de voltaje de funcionamiento: 3.6~4.4kV
Corriente nominal1000AMax peak current: 2000A (2 times rated value)
Power DevicesIGBT TypeHigh-voltage IGBT Module1700V/1200A, ABB customized version
Topology3-level NPC (Neutral Point Clamped)Reduce dv/dt and motor insulation stress
Cooling ModeEnfriamiento por aire forzadoVentilador de refrigeración incorporado, redundant design supported
Parámetros eléctricosFrecuencia de entrada50/60Hz, ±5%Compatible with global power grid standards
Frecuencia de conmutación2~8kHz (Ajustable)Balance energy efficiency and noise performance
Pérdida de energíaAprox.. 1.2kW per moduleUnder typical working conditions
Clase de aislamientoOvervoltage Category IV (CEI 60664)Meet insulation requirements of medium-voltage systems
Parámetros mecánicosDimensión (L×An×Al)650×450×320mmStandard Frame 1 tamaño
Peso neto48.5kilosExcluding packaging
Clase de protecciónIP20Adecuado para instalación en gabinete
Funciones de protecciónProtección contra sobrecorriente2000A (2 times rated)Short-circuit response time <10μs
Protección contra sobretensión4.4kVDC bus overvoltage protection
Over-temperature Protection100℃IGBT module overtemperature protection
Protección contra subtensión3.6kVGrid undervoltage protection
Certificaciones & CumplimientoCE CertificateCompliant with EN 61800-5-1
UL CertificateMeet North American medium-voltage equipment standards
IEEE 519 CumplimientoTotal harmonic distortion <5%
  1. Full Model List of ACS 2040 Series Phase Modules
ModeloNúmero de pedido.Tensión nominalCorriente nominalApplicable InverterNotas
ACS 2040-PMK10002UEA0013454kV1000AACS 2040 Marco 1Standard phase module
ACS 2040-PMK10002UEA0011414kV1000AACS 2040 Marco 1Complementary phase module
ACS 2040-PMK12002UEA0013464kV1200AACS 2040 Marco 1High current version
ACS 2040-PMK8002UEA0013474kV800AACS 2040 Marco 1Low current version
ACS 2040-PMK1000-6kV2UEA0013486kV1000AACS 2040 Marco 26kV dedicated version
  1. Reemplazo & Modelos equivalentes

4.1 Internal ABB Replacement

Old ModelNew ModelReplacement Description
ACS 1040-PMK1000ACS 2040-PMK1000 (2UEA001345)Upgraded to 3-level topology, efficiency increased by 2%, harmonic distortion reduced by 30%
ACS 2040-PMK800 (2UEA001347)ACS 2040-PMK1000 (2UEA001345)Higher current model in the same series, wider power coverage

4.2 Cross-brand Equivalent Products

MarcaModelo equivalenteVentajas
siemensSINAMICS GM150 Power ModuleSuperior 3-level topology, lower dv/dt, better motor insulation protection
Electricidad SchneiderAltívar 6100 Medium Voltage ModuleEasier maintenance with modular design, higher MTBF (>100,000 hours)
Mitsubishi ElectricMV-VFD Power ModuleWider applicable voltage range (3.6-4.4kV), mayor adaptabilidad ambiental
  1. Escenarios de aplicación & Industry Cases

5.1 Recommended Applications

Tipo de aplicaciónCondiciones de trabajo típicasVentajas principales
Industrial FansPower plant induced draft fans, cement plant kiln fans, steel plant dust removal fansWide speed regulation range (0.1-100Hz), 30%-40% ahorro de energía
Industrial Water PumpsWater plant high-pressure water supply pumps, mine drainage pumps, petrochemical circulating pumpsSoft start without impact, reduce pipeline stress and extend service life
CompresoresCompresores de aire, natural gas compressors, refrigeration compressorsPrecise pressure control, reduce no-load loss and improve energy efficiency
TransportadoresLong-distance mine conveyors, port container conveyorsSmooth speed regulation, avoid material accumulation and mechanical wear
General Industrial EquipmentMezcladores, trituradoras, extrusoras, etc..Modular design for convenient maintenance, MTBF>100,000 hours

5.2 Not Recommended Usage Scenarios

Explosion-proof areas (non-explosion-proof structure, customized version required)

Offshore platforms (additional anti-corrosion treatment needed)

Ultra-high voltage systems above 4.4kV (select 6kV version instead)

Equipment with frequent start-stop operations (más que 10 veces por hora, special customized modules recommended)

5.3 Practical Cases

Caso 1: Induced Draft Fan Renovation in Thermal Power Plant

Original system: Fixed-speed motor + baffle adjustment, high energy consumption and severe baffle wear

Renovation solution: ACS 2040 inverter + 3 sets of 2UEA001345 phase modules (3-fase)

Effect: Energy consumption reduced by 38%, annual electricity cost saved about 1.8 million RMB, baffle maintenance cycle extended 5 veces

Caso 2: High-pressure Water Supply System for Large Water Plant

Demand: Constant pressure water supply with large load fluctuation (20%-100%)

Solución: ACS 2040 Marco 1 (3 pcs 2UEA001345 modules) + PID control system

Effect: Stable pressure deviation within ±0.05MPa, 32% ahorro de energía, service life extended by 3 años

  1. Air Shipment Compliance & Certification Guide

6.1 Shipment Compliance Confirmation

ArtículoEstadoExplicación
Built-in Lithium BatteryNoOnly electronic components and IGBT modules equipped
Dangerous Goods ClassificationNon-dangerous goodsCompliant with IATA DGR Class 9, no special shipping restrictions
Transport RestrictionsNingunoCan be shipped as ordinary industrial equipment
Packaging StandardStandard shockproof packageFix IGBT modules firmly to avoid damage during transit
Rango de temperatura-20℃ ~ +50℃Avoid extreme temperature during transportation

6.2 Certification Document Acquisition

CE Certificate: Available for download on official ABB website (Document ID: ACS2000-PHTC01U-EN)

UL Certificate: Apply via ABB global technical support center

Manufacturer Declaration: Including EMC, safety and RoHS compliance statements

  1. Directrices de selección & Quick Rules

Selection Rules

  1. Coincidencia de voltaje: 2UEA001345 for 4kV systems; choose 2UEA001348 for 6kV systems
  2. Selección actual: 1000A standard (PMK1000), 800A low current (PMK800), 1200una corriente alta (PMK1200)
  3. Compatibilidad del sistema: Only applicable to ACS 2040 serie (ACS2000 platform) Marco 1 tamaño
  4. Quantity Matching: 3 phase modules required for one 3-phase inverter, 1 spare module is recommended
  5. Consejos de mantenimiento: Regularly inspect cooling fans, replace IGBT modules every 5 years to ensure stable insulation performance
  6. Main Accessories & Configuración recomendada
Nombre del accesorioModeloFunción
Unidad de controlACS 2040-CUCore control unit matched with phase modules
Cooling Fan3HAC031683-001Special cooling fan for phase modules, support redundant operation
Drive Board3HAC031684-001IGBT drive circuit with integrated protection functions
Voltage Sensor3HAC031685-0014kV system voltage monitoring, realize over/under voltage protection
Current Sensor3HAC031686-0011000A current detection, sobrecorriente & protección contra cortocircuitos
Installation Kit3HAC031687-001Including fixing bolts, gaskets, insulating sleeves etc.

Anterior:

Deja una respuesta

Dejar un mensaje