chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

Carlo Gavazzi VNY 4 Sensor de nivel NS/NT - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

NoticiasNoticias comerciales

Carlo Gavazzi VNY 4 Sensor de nivel NS/NT

Carlo Gavazzi VNY 4 Sensor de nivel NS/NT (Número de artículo. 481046)

Resumen central: El VNY 4 NS/NT es un sensor de nivel de inserción de 4 electrodos diseñado por Carlo Gavazzi específicamente para líquidos conductivos, Número de artículo. 481046.

It is used for high/low level control in tanks and vessels, suitable for industrial automation and process control applications.

  1. Model and Item Number Explanation
ArtículoDescripción
Modelo completoVNY 4 NS/NT
Número de artículo. / Código de pedido481046
MarcaCarlo Gavazzi
Tipo de productoConductive Level Sensor
Number of Electrodes4 Electrodes
Mounting Connection1½ISO 228/1 pipe thread (G1½”)
Electrode MaterialStainless Steel (SS)
Material de la carcasaNylon 6
Standard Electrode Length1 metro (can be cut to length)
  1. Core Technical Specifications
ArtículoEspecificaciónNotas
Sensing PrincipleConductive (activated by liquid conductivity)For conductive liquids only; non‑conductive liquids require ultrasonic/radar sensors
Supply VoltageRequires an amplifier relayNo built‑in electronics; must be driven by an external control unit
Rated Pressuremáx.. 10 barSuitable for medium‑high pressure vessels/tanks
Temperatura de funcionamiento-25°C ~ +80°CCovers most industrial process applications
Clasificación de protecciónIP65Dust‑tight and protected against water jets; suitable for wet/corrosive environments
Electrode DetailsØ4 mm stainless steel, longitud estándar 1 metroCan be cut on‑site to match level height
Mounting Thread1½ISO 228/1 (G1½”)Standard industrial pipe thread, compatible with most tank connections
AlambradoScrew terminals / PG13 cable glandEasy installation, reliable connection
Proceso de dar un títuloCEComplies with European electrical safety standards
  1. Características y ventajas del producto
  2. Alta compatibilidad

Designed specifically for conductive liquids (water, acids, alkalis, beverages, etc.) for level high/low control and alarm

4‑electrode design improves detection reliability and prevents false triggering

Electrodes can be cut on‑site for flexible adaptation to various level heights

  1. Robust and Durable

Stainless steel electrodes are corrosion and wear‑resistant, suitable for harsh environments such as chemical, food and pharmaceutical industries

Nylon 6 housing with high mechanical strength and impact resistance; IP65 for outdoor and wet environments

10 bar rated pressure for medium‑high pressure tanks and pressure vessels

  1. Flexible Expansion

Must be used with Carlo Gavazzi amplifier relays (p.ej., RN series) for switching output and logic control

Supports integration with PLC and DCS systems to build automated level monitoring networks

  1. Aplicaciones típicas

Chemical storage tanks: level monitoring and high/low alarm for conductive liquids such as acids, alkalis and solvents

Food and beverage: level control for water tanks, fermentation tanks and dosing tanks

Water treatment: level monitoring of raw water, clean water and sewage tanks

Pharmaceutical industry: level and safety interlock for reactors and storage tanks

Industrial circulating water: automatic water supply/drainage for cooling towers and reservoirs

  1. Accessories and Replacement Options
  2. Required Accessory (Amplifier Relay)

The sensor has no built‑in electronics and must be used with a Carlo Gavazzi amplifier relay. Recommended models:

RN series: RN1A4024, RN2A4024, etc., with 24VDC/230VAC output for different control circuits

  1. Same‑Brand Replacements
Original ModelReemplazoKey DifferenceSolicitud
VNY 4 NS/NT (481046)VNYI4Upgraded electrode insulation (PE insulation), stronger anti‑interferenceHigh‑purity / corrosive liquid applications
VNY 4 NS/NTVNY2 NS/NT2‑electrode configuration, lower costSimple level control with low accuracy requirements
VNY 4 NS/NTVNY4‑PUPush‑In terminals, wiring efficiency increased by 60%Mass installation and fast wiring
  1. Cross‑Brand Equivalent Replacements
MarcaEquivalent ModelKey Matching Specifications
WeidmullerIPL VNY 44 electrodes, 1½thread, 10 bar pressure
Phoenix ContactSENTRON VNY 4Conductive level detection, compatible with 1 m electrodes
CHINTCZY 401Domestic alternative, 4 electrodes, stainless steel, G1陆thread
  1. Selection and Usage Guidelines
  2. Liquid Compatibility

Only for conductive liquids (conductivity ≥ 10 µS/cm); non‑conductive liquids (p.ej., oils) require ultrasonic or radar level sensors

  1. Especificaciones de instalación

Mounting thread: 1½ISO 228/1 (G1½”); confirm tank connection size before installation

Electrode insertion depth depends on control range; estándar 1 m electrodes can be cut on‑site

  1. Requisitos de cableado

The sensor is only an electrode probe and must be used in series with an amplifier relay for power and switching output

Observe electrode polarity during wiring to avoid short circuits and ensure good contact

  1. Consejos de mantenimiento

Clean electrode surfaces regularly to prevent fouling that affects accuracy

Inspect terminal tightness and insulation every 6–12 months to avoid poor connections

> Nota: El VNY 4 NS/NT (Número de artículo. 481046) is a standard industrial level sensor from Carlo Gavazzi, widely used in process automation systems. It is fully compatible with the brand’s ComPacT series relays and PLC controllers, and can be directly used for system upgrades and new projects.

Anterior:

Próximo:

Deja una respuesta

Dejar un mensaje