Descripción general del producto & Desglose del modelo
C125N420FM is a 4‑pole molded case circuit breaker from Schneider Electric’s ComPacT NS1250N series, equipped with a MicroLogic 2.0 control unit.
It is used for overload and short‑circuit protection in low‑voltage power distribution systems, widely applied in industrial plants, edificios comerciales, and infrastructure projects.
| Segmento de modelo | Descripción |
| C125N | ComPacT NS1250N series, frame size 1250A, breaking capacity 50kA@415VAC |
| 4 | 4‑pole configuration (4PAG) |
| 20 | Micrológica 2.0 control unit (funciones básicas de protección) |
| FM | Fixed mount, operación manual, front connection |
- Especificaciones técnicas básicas
| Artículo | Valor | Notas |
| Modelo | Schneider Electric C125N420FM | Full description: ComPacT NS1250N 4P 1250A 50kA MIC2.0 |
| Marco actual | 1250A | Maximum rated operational current |
| polacos | 4 polos (4PAG) | 3 fases + protección neutra |
| Trip unit | Micrológica 2.0 | Long‑time (l), poco tiempo (S), instantáneo (I) protección |
| Corriente nominal (Y) | 1250A | Adjustable via trip unit |
| Ultimate breaking capacity (uci) | 50kA@415VAC | Complies with IEC 60947‑2 |
| Montaje | Fijado, front connection | Suitable for standard switchgear |
| Operación | Manual | With mechanical indication and lockability |
| Tensión nominal de aislamiento (interfaz de usuario) | 1000VACACIONES | CEI 60947‑2 |
| Tensión operativa nominal (ue) | 400/415VACACIONES (50Hz) | Standard 3‑phase voltage |
| Short‑time withstand current (Icw/1s) | 50el | Ensures system stability during faults |
| Grado de protección | IP30 | Protection against solid foreign objects |
| Capacidad de cableado | máx.. 300mm² copper | For high‑current loads |
- Características & Ventajas
- Protección integral
Micrológica 2.0 provides 3‑stage protection (L‑S‑I) with adjustable settings.
Supports fault diagnostics and alarm output for easy maintenance.
- Efficient design
Green “T” design reduces panel wiring time by 40%.
Ergonomic operating handle for improved safety and comfort.
Modular structure supports accessories: contactos auxiliares, contactos de alarma, liberación de subtensión, etc..
- Reliable performance
50kA high breaking capacity for fast fault interruption.
Vida mecánica: arriba a 10,000 operaciones; vida electrica: arriba a 5,000 operaciones.
Temperatura ambiente: −5°C to +40°C (full rating), −25°C to +70°C (derated).
- Instalación & Aplicaciones
4.1 Requisitos de instalación
Suitable for standard distribution boards with industry‑standard mounting depth.
Front connection for easy wiring and maintenance.
Sufficient heat dissipation space required for stable long‑term operation.
4.2 Aplicaciones típicas
Incoming protection for main power distribution boards in industrial plants
Power distribution systems for large commercial complexes
UPS input/output protection in data centers
Critical load protection in infrastructure (hospitales, airports, metros)
Main protection for Motor Control Centers (MCC)
- Related Models & Alternativas
5.1 Derived models in the same series
| Modelo | Diferencia | Solicitud |
| C125N320FM | 3 polos (3PAG) | 3‑phase loads without neutral protection |
| C125N450FM | Micrológica 5.0 unidad de viaje | Energy measurement and advanced protection |
| C125N420PM | Draw‑out installation | Easy maintenance without power interruption |
| C125N420RM | Plug‑in installation | Fast replacement for backup equipment |
5.2 Cross‑series alternatives
| Reemplazo | Serie | Main difference | Price reference |
| NSX1250N 4P MIC2.0 | NSX compacto | Nueva generación, capacidad de corte 65kA | Aprox.. +10% |
| Masterpact MTZ12 | Masterpact MTZ | Air circuit breaker for higher power systems | Aprox.. +50% |
5.3 Competitive brand equivalents
| Marca | Reemplazo | Clasificación |
| siemens | 3WL1212‑3CB36‑4GA4 | 1250A 4P 50kA basic protection |
| TEJIDO | Tmax T6H1250 PR221DS‑LSI 4P | 1250A 4P 50kA LSI protection |
| Eaton | NZM4‑1250N 4P | 1250A 4P 50kA basic protection |
- Adquisitivo & Consejos de uso
- Authentic procurement: Purchase via authorized Schneider Electric distributors or official channels to ensure quality and service.
- Accesorios: Contactos auxiliares opcionales, contactos de alarma, shunt trip, liberación de subtensión, etc..
- Configuración de parámetros: Micrológica 2.0 can be programmed; adjust according to load characteristics.
- Mantenimiento: Routine inspection every 1–2 years, including mechanism, terminales, and protection functions.
> Nota: C125N420FM complies with IEC 60947‑2, ES 14048.2 and other international & national standards. It is fully compatible with Schneider Prisma E, Blokset and other panel systems.
- Selección & Pautas de reemplazo
- Reglas de compatibilidad
Los zócalos de relé industriales siguen dimensiones estándar internacionales y son intercambiables entre marcas si:
El recuento de pines coincide con el número de polo del relé
Corriente nominal (≥10A) cumple con la carga
Montaje (Carril DIN/tornillo) coincide con el diseño del panel
- Selección del tipo de terminal
tornillo convencional: PTF08A / PTF11A / PTF14A: adecuado para entornos de baja vibración
Protección de dedos: Serie PTFZ: adecuada para zonas con acceso frecuente
Empuje Plus: Serie PTF-PU: ideal para cableado masivo, alta resistencia a las vibraciones
- Modelos discontinuados
PTF08A-E / PTF14A-E están descontinuados con stock limitado.
Utilice la serie PTFZ como reemplazo preferido.
> Nota: Los enchufes de la serie PTF tienen una clasificación de 10 A/250 VCA., rigidez dieléctrica CA 2000V, temperatura de funcionamiento −25 °C a +55 °C, adecuado para cables de cobre de 0,5–2,5 mm².
contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares