Emerson Rosemount 6R8HCI-58-C Platinum Resistance Temperature Sensor (IDT) PDF
6R8HCI-58-C es un modelo combinado de Emerson Rosemount 68 Sensor de temperatura RTD de platino de elemento único serie y funda de corte a medida serie 58C. Está especialmente diseñado para la medición de temperatura de procesos industriales., adopción de un elemento de película delgada Pt100 con múltiples opciones de montaje. Adecuado para el rango de temperatura de -58°F a 392°F (-50°C a 200°C).
- Definición del segmento del modelo
| Segmento | Significado | Descripción detallada |
| 6 | Sensor Series | 68 Series single-element RTD (6 = single-element; 8 = thin-film type) |
| R8 | Resistencia & Clase de precisión | R = 100Ω (Pt100); 8 = Class B accuracy (±0.3°C @ 0°C) |
| h | Sheath Material | H = 316 Acero inoxidable (Standard SST), corrosion-resistant for most industrial environments |
| do | Connection Head Type | C = Polypropylene connection head, excellent insulation and chemical corrosion resistance |
| I | Lead Configuration | I = 3-wire system, effectively compensates lead wire resistance and improves measurement accuracy |
| -58 | Rango de temperatura | -58°F to 392°F (-50°C a 200°C), matched with 58C series sheath |
| -do | Sheath Series | 58C Series Cut-to-Fit sheath; length can be trimmed with standard pipe cutters on site |
- Parámetros de especificación principales
| Categoría de parámetro | Índice técnico | Observaciones |
| Características básicas | ||
| Tipo de producto | Single-element Platinum Resistance Temperature Sensor (IDT) | 68 Series thin-film type, 58C Series cut-to-fit sheath |
| Marca | Emerson Rosemount | Benchmark brand in industrial process measurement |
| Resistance Element | Pt100 (100Ω @ 0°C) thin-film type | Fast response and high long-term stability |
| Clase de precisión | Clase B (CEI 60751) | ±0.3°C @ 0°C, ±0.004°C/°C above 0°C |
| Rango de temperatura | -58°F to 392°F (-50°C a 200°C) | Temperature limit of 58C series sheath |
| Especificaciones eléctricas | ||
| Lead Configuration | 3-cable | Eliminates lead resistance influence and improves measuring accuracy |
| Lead Material | PTFE insulated, silver-plated copper, 24AWG stranded wire | Temperature resistant, chemical resistant and high conductivity |
| Resistencia de aislamiento | ≥1000MΩ @ 500Vdc (room temperature) | Ensures integrity of measurement signal |
| Tiempo de respuesta | 12 artículos de segunda clase (63.2% response in 3ft/s water flow) | Fast response for thin-film element |
| Especificaciones físicas | ||
| Sheath Material | 316 Acero inoxidable | High corrosion resistance and mechanical strength |
| Sheath Diameter | 0.25 pulgada (6.35milímetros) | Tamaño estándar, compatible with most thermowells |
| Sheath Length | Standard lengths: 12″, 24″, 36″, 48″ | Trimmable to any length, no need to stock multiple sizes |
| Connection Head Material | Polypropylene | Superior insulation and chemical resistance |
| Terminal Design | 6-terminal configuration | Easy wiring and compatible with various transmitters |
| Condiciones ambientales | ||
| Temperatura de funcionamiento | -58°F to 392°F (-50°C a 200°C) | Limited by 58C sheath temperature rating |
| Humidity Resistance | 100% humedad relativa | Lead sealing withstands high-humidity environments |
| Resistencia a las vibraciones | ±0.05% maximum ice-point resistance drift | Compliant with industrial vibration requirements |
| Protección de ingreso | IP65 | Connection head protected against dust and water intrusion |
| Certificaciones & Estándares | ||
| Main Standards | CEI 60751, ANSI MC96.1 | Globally recognized temperature sensor standards |
| Marcas de certificación | CE, UL, CSA | Compliant with international safety regulations |
- Lista de accesorios & Mounting Parts
| Nombre de la pieza | Especificación | Función | Escenario de aplicación |
| 58C Sheath | Cut-to-fit stainless steel sheath | Protects sensor element and provides mechanical support | General industrial process temperature measurement |
| Polypropylene Connection Head | Insulated type | Provides electrical connection and environmental protection | Ambientes corrosivos & high insulation requirements |
| 3-Wire Lead Assembly | PTFE insulated silver-plated copper wire | Transmits temperature signal with 3-wire resistance compensation | High-precision temperature measurement |
| Heat Shrink Tubing | Insulation protective sleeve | Seals and protects lead-to-sensor joint | On-site installation for enhanced tightness |
| Manual de instalación | Operation guideline | Detailed installation procedures and precautions | Field installation guidance |
| Temperature Calibration Certificate | Calibration report | Provides sensor accuracy and calibration data | Quality traceability and ISO compliance |
| Mounting Fittings | Compression fitting / Spring-loaded fitting | Fixes sensor inside thermowell | Adapt to different mounting methods |
- Competidor & Modelos equivalentes entre marcas
| Marca | Modelo de reemplazo | Características similares | Diferencias |
| TEJIDO | TSP400-100-B-3-0.25 | Pt100, Clase B, 3-cable, 0.25″ sheath | Different head material, slightly lower price |
| siemens | 7NG3211-0NN00 | Pt100, Clase B, 3-cable, stainless steel sheath | Slightly slower response time (~15s) |
| Yokogawa | TR10-100B-3-025 | Pt100, Clase B, 3-cable, 0.25″ sheath | Mismo rango de temperatura, slightly higher calibration accuracy |
| Rosemount Internal Alternative | 7R8HCI-58-C | Pt100, Clase A, 3-cable, 316SST sheath | Class A accuracy (±0.15°C @ 0°C), mayor costo |
| Rosemount Internal Alternative | 6R8HPI-58-C | Pt100, Clase B, 3-cable, Hastelloy sheath | Stronger corrosion resistance for harsh chemical environments |
- Directrices de selección & Soluciones de reemplazo
5.1 Parámetros de selección clave
| Parámetro | Puntos clave de selección | Especificación recomendada |
| Clase de precisión | Select according to measurement requirements; Class B for most industrial applications | Clase B (±0.3°C); High-precision use Class A (±0.15°C) |
| Lead Configuration | 3-wire compensates lead resistance; 4-wire for highest accuracy | 3-cable (estándar); 4-wire for laboratory & precision measurement |
| Sheath Material | 316SST for general environments; Hastelloy for heavy corrosion | 316SST (estándar); Hastelloy for chemical industry |
| Connection Head Material | Polypropylene for insulation; Aluminum for heat dissipation; Stainless steel for corrosion resistance | Polypropylene for corrosive sites; Aluminum for high-temperature sites |
| Rango de temperatura | 58C Series: -50°C~200°C; 68 Standard Series: -50°C~400°C | 58C for general industry; 68 standard sheath for high temperature |
| Sheath Length | 58C cut-to-fit design, no need for multiple inventory lengths | Choose standard length by insertion depth (12″/24″/36″/48″) |
5.2 Recomendaciones de reemplazo
Insufficient temperature range: Adopt 68 standard sheath model 6R8HCI-68, range extended to -50°C~400°C
Higher accuracy required: Select 7R8HCI-58-C (Class A accuracy, ±0.15°C @ 0°C)
Severe corrosion environment: Use 6R8HPI-58-C (Hastelloy) or 6R8HCI-58-T (Titanium) sheath
Faster response required: Choose 68Q fast-response series, response time reduced to 5 artículos de segunda clase
4-wire measurement needed: Select 6R8HCW-58-C to eliminate all lead resistance error
5.3 Precauciones de aplicación
- Trim the 58C sheath to required length with a standard pipe cutter before installation; reserve sufficient length for connection head assembly.
- Keep three lead wires equal in length for optimal resistance compensation in 3-wire connection.
- Avoid long-term operation above 392°F (200°C), exceeding the 58C sheath temperature limit.
- Ensure full contact between sensor tip and thermowell bottom during installation to minimize measurement error.
- Regularly inspect connection head sealing to prevent moisture ingress and accuracy drift.
- When matched with temperature transmitters (p.ej. Rosemount 3144S), correctly configure sensor type and parameters in the transmitter.
- Escenarios de aplicación típicos
Chemical process temperature measurement (corrosive environments; polypropylene head provides reliable insulation)
Alimento & beverage industry (316 stainless steel complies with sanitary standards; cut-to-fit length adapts to various equipment)
Water treatment systems (chlorine corrosion resistance; 3-wire design ensures stable accuracy)
sistemas de climatización (matched temperature range and flexible installation)
Pharmaceutical industry (high-precision measurement compliant with GMP requirements)
Power industry (transformador & generator winding temperature monitoring; 3-wire compensates cable resistance)
Aceite & gas industry (pipeline and storage tank temperature measurement with corrosion-resistant sheath)
contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares