chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

Frequency Converter Comparison Table of Mainstream Brands - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

NoticiasNoticias comerciales

Frequency Converter Comparison Table of Mainstream Brands

This document provides model correspondence, power coverage, core parameters, application scenarios and replacement recommendations for frequency converters de 12 mainstream global brands, facilitating rapid cross-brand selection and replacement. It covers four application categories: general-purpose, fan & pump-specific, heavy-duty industrial, and economical.

  1. General-Purpose Frequency Converter Comparison (0.37kW~75kW)
MarcaSerieRango de potenciaMétodo de controlCore FeaturesTypical ModelReplacement Reference
TEJIDOACS5800.37kW~250kWVector Control/Sensorless VectorRugged and durable, IP55 protection optional, built-in EMCACS580-01-04A5-4 (2.2kilovatios)Siemens G120, Schneider ATV340
siemensSINAMICS V200.12kW~30kWV/f Control/Vector ControlEasy operation, integrated filter, suitable for OEM6SL3210-5BE17-5UV0 (7.5kilovatios)ABB ACS150, Delta VFD-E
siemensSINAMICS G1200.37kW~250kWVector Control/Servo ControlDiseño modular, PROFINET integration6SL3224-0BE27-5UA0 (30kilovatios)ABB ACS580, Schneider ATV340
SchneiderAltivar 3200.37kW~75kWVector Control/Torque ControlCompact size, built-in PLC functionATV320U07M2C (0.75kW single-phase)Mitsubishi FR-D740, Fuji FRENIC-Mini2
SchneiderAltivar 3400.37kW~250kWAdvanced Vector ControlAdaptive control, multi-pump linkageATV340D15N4 (15kilovatios)ABB ACS580, Siemens G120
MitsubishiFR-A8000.4kW~500kWVector Control/Torque Control200% torque output at 0.5Hz, suitable for heavy loadsFR-A840-00720-2-60 (30kilovatios)Yaskawa A1000, Danfoss FC302
MitsubishiFR-D7400.4kW~75kWV/f Control/Basic VectorEconómico, compact sizeFR-D740-015SC-EC (7.5kilovatios)Chint NVF2, Delixi CDI9100
YaskawaA10000.4kW~500kWVector Control/Position ControlFast response speed, high torque precisionCIMR-AB4A0018FBA (7.5kilovatios)Mitsubishi FR-A800, Siemens G120
FujiFRENIC-MEGA0.75kW~630kWVector Control/Direct TorqueTriple overload protection, suitable for shock loadsFRN0015E2S-4C (7.5kilovatios)Yaskawa A1000, ABB ACS580
DeltaVFD-E0.4kW~75kWVector Control/Torque ControlBuilt-in EMI filter, comunicación RS485VFD037E43A (3.7kilovatios)Schneider ATV320, Mitsubishi FR-D740
InovanceMD2800.4kW~75kWVector Control/Sensorless VectorHigh-quality domestic product, cost-effective, strong adaptabilityMD280T3.7GB (3.7kilovatios)Delta VFD-E, Chint NVF2
chintNVF20.75kW~90kWV/f Control/Vector ControlMainstream domestic brand, 3C certified, suitable for civil engineeringNVF2-11/TS4 (11kilovatios)Delixi CDI9100, Delta VFD-E
  1. Fan & Pump-Specific Frequency Converter Comparison
MarcaSerieRango de potenciaFunciones especialesEnergy Efficiency ClassTypical ModelReplacement Recommendation
TEJIDOACS3800.37kW~160kWMulti-pump control, sleep/wake-up functionIE2+ACS380-040S-03A3-4 (1.5kilovatios)Schneider ATV630, Danfoss FC111
TEJIDOACH5500.75kW~500kWHVAC-specific, enthalpy controlIE2+ACH550-UH-03A3-4 (1.5kilovatios)Schneider ATV630, Johnson Controls Frequency Converter
SchneiderAltivar 6300.75kW~630kWFan surge suppression, pump dry-run protectionIE3ATV630U15N4 (15kilovatios)ABB ACS380, Danfoss FC111
DanfossFC1110.37kW~160kWAutomatic energy optimization, sleep modeIE3131B0100 (4kilovatios)ABB ACS380, Schneider ATV630
MitsubishiFR-F7400.75kW~450kWFan/pump-specific algorithm, energy-saving modeIE2FR-F740-030SC-EC (15kilovatios)Fuji FRENIC-NewVP, Yaskawa H1000
FujiFRENIC-NewVP0.75kW~630kWMulti-pump cycle control, stable pipe network pressureIE3FRN0030E2S-4C (15kilovatios)Mitsubishi FR-F740, Schneider ATV630

III. Heavy-Duty Industrial Frequency Converter Comparison (75kW~500kW)

MarcaSerieRango de potenciaCapacidad de sobrecargaEscenarios de aplicaciónTypical ModelTechnical Highlights
TEJIDOACS8800.75kW~5.6MW180%/60sHeavy industry, multi-machine parallel operation, energy feedbackACS880-01-09A5-3 (4kilovatios)Torque response < 5EM, supports synchronous motor control
siemensSINAMICS S1200.5kW~4.5MW200%/3sHigh-precision servo, complex motion control6SL3120-1TE28-5AA3 (45kilovatios)Vector control accuracy 0.01%, digital twin integration
YaskawaH10001.5kW~630kW180%/60sHoisting/lifting, compresores, large fansCIMR-HB4A0090FBC (37kilovatios)Unidad de frenado incorporada, suitable for potential energy loads
DanfossFC3020.75kW~250kW170%/60sTextile machinery, extruders, heavy-duty pumps132F0040 (15kilovatios)Adaptive motor model, low harmonic output
InovanceMD88011kW~500kW180%/60sHigh-quality domestic heavy-duty product, suitable for metallurgy/miningMD880T45G (45kilovatios)30% cost reduction compared with imported brands, close performance
  1. Economical Frequency Converter Comparison (0.12kW~15kW)
MarcaSerieRango de potenciaGama de preciosEscenarios de aplicaciónTypical ModelReplacement Advantages
TEJIDOACS1500.37kW~15kWMedium-LowSmall pumps/fans, simple machineryACS150-03E-01A2-4 (0.75kilovatios)Compact size, fácil instalación, IP20 protection
DeltaVFD-M0.4kW~15kWMedium-LowSmall automation equipment, OEM supportingVFD007M43B (0.75kilovatios)Cost-effective, simple operation, strong adaptability
chintNVF10.75kW~15kWLowCivil construction, small machinery, cost priorityNVF1-015/TS4 (15kilovatios)Entry-level domestic brand, 3C certified, convenient after-sales service
DeliciosoCDI91000.75kW~15kWLowReplacement for Chint NVF1, slightly better performanceCDI9100-0R75G/1R5P (0.75kilovatios)Lower price, suitable for domestic power grid fluctuations
  1. Core Principles and Precautions for Cross-Brand Replacement
  2. Three Essential Factors for Replacement Selection (Must Match)
FactorMatching StandardRisk of Mismatch
Power RatingRated current ≥ original model, power deviation ≤ ±5%Overload protection failure, module burnout
Método de controlAt least equivalent to the original model (Vector→Vector, V/f→V/f)Performance degradation, insufficient control precision
Clasificación de voltajeInput/output voltage completely consistent (380V/400V/690V)Insulation breakdown, equipment damage
  1. Key Parameter Checklist
  2. Capacidad de sobrecarga: Must be ≥150%/60s for heavy-duty applications, ≥120%/60s for general loads
  3. Clase de protección: Select IP20 (indoor cabinet)/IP54 (outdoor)/IP66 (underwater) as required
  4. Protocolo de comunicación: Modbus/Profibus/Profinet/EtherNet/IP must be compatible with the system
  5. Installation Dimensions: Ensure consistent rail/panel mounting holes during replacement to avoid re-drilling
  6. Accessory Compatibility: Braking units, filters, and reactors must match the parameters of the new frequency converter
  7. Recommended Common Replacement Combinations
Original Brand SeriesRecommended Replacement Brand SeriesReplacement Advantages
Siemens V20ABB ACS150/Schneider ATV320Lower price, equivalent functions
ABB ACS550Siemens G120/Schneider ATV340Updated technology, lower maintenance cost
Mitsubishi FR-D740Delta VFD-E/Inovance MD280Domestic replacement, cost-effective
Schneider ATV312Chint NVF2/Delixi CDI910040% cost reduction, meets basic requirements
  1. Quick Selection Decision Table
Escenario de aplicaciónPreferred Brand SeriesRango de potenciaMétodo de controlEssential Functions
Small Fans/PumpsABB ACS150, Siemens V200.37kW~7.5kWV/f ControlSleep function, protección contra sobrecarga
Medium-Sized Industrial MachineryABB ACS580, Siemens G12011kW~75kWVector ControlBuilt-in EMC, communication interface
Large Fans/PumpsABB ACS380, Schneider ATV63030kW~250kWSpecial AlgorithmMulti-pump control, anti-surge
Heavy-Duty Equipment/HoistingABB ACS880, Yaskawa H100045kW~500kWVector Control + Braking180% sobrecarga, energy feedback
Cost-Priority ProjectsDelta VFD-E, Inovance MD2800.75kW~37kWVector ControlBasic functions, 3C certification
  1. Reglas de nomenclatura de modelos: There are significant differences in model coding among various brands. Focus on three core parts: power code, voltage rating, and control method
  2. Latest Replacement Information:

ABB ACS550 has been upgraded to ACS580 (fully compatible with installation dimensions)

Siemens MM4 series has been replaced by SINAMICS V20/G120

Schneider ATV312 has been upgraded to ATV320 (enhanced functions, smaller size)

  1. Domestic Replacement Trend: Domestic brands such as Inovance, Delta and Chint have approached the performance of imported brands in the 0.75kW~37kW power range, with a price advantage of 30%~50%

Anterior: