LC1DWK12p7 is a three-phase capacitor switching contactor specially designed by Schneider Electric for reactive power compensation systems. It is mainly used to switch power capacitors so as to improve grid power factor, reduce line loss and enhance power quality.
- Model Segment Definition
| Segmento de modelo | Significado | Descripción |
| LC1 | Código de serie del contactor | Basic code for Schneider TeSys series contactors |
| D | Serie de productos | Serie TeSys D, standard industrial contactor |
| W. | Special application | Dedicated for capacitor switching |
| k | Capacidad nominal | Matches 63kVAR capacitor at 400V/50Hz |
| 12 | Corriente nominal | 12A (special rating for capacitor switching) |
| p7 | voltaje de la bobina | 230V CA 50/60 Hz |
- Main Application Scenarios
2.1 Industrial Power System Power Factor Compensation
Factory power distribution system: Heavy industries such as steel, chemical and machinery manufacturing with intensive inductive loads like motors and inverters, requiring dynamic reactive power compensation.

Substation / Distribution station: 10kV/0.4kV power distribution system adopting centralized compensation to improve overall power supply efficiency.
Production line dedicated compensation: Grandes líneas de producción, compressor stations, water pump rooms, etc., automatically switching capacitors according to load changes.
2.2 Edificios Comerciales & Instalaciones públicas
Edificios de oficinas / Shopping malls: Large electrical equipment such as central air conditioning, elevators and lighting systems adopting centralized compensation to reduce electricity costs.
Centros de datos: Non-linear loads such as UPS and server clusters requiring precise compensation to maintain voltage stability.
hospitales / Schools: Power supply systems for critical loads to improve power supply reliability and power quality.
2.3 Nueva energía & Special Industries
fotovoltaica / Wind power systems: Compensate reactive power loss at the output of grid-connected inverters to meet grid connection standards.
Tránsito ferroviario: Traction substations and depots for compensating inductive reactive power of traction loads.
Minería / Oilfield: Off-grid power supply systems in remote areas to improve power generation equipment utilization.
- Special Design Advantages for Capacitor Switching
- Pre-wired damping resistor: Suppresses inrush current (arriba a 100 veces la corriente nominal) durante la conmutación del condensador, protecting capacitors and contactor contacts.
- Early-make auxiliary contact: Ensures the damping resistor is connected first before the main contacts close, achieving inrush-free switching.
- Optimized contact material: Adapted to high-frequency operation (arriba a 240 cycles/hour) and arc characteristics of capacitor switching.
- Wide temperature design: -25℃ ~ +60℃, adecuado para entornos industriales hostiles.
- Typical Application Topology
Power Grid → Circuit Breaker → Reactor → LC1DWK12p7 Contactor → Power Capacitor → Load
Used together with reactors to further suppress inrush current and harmonics.
Linked with power factor controllers (p.ej., Schneider Varlogic series) to realize automatic compensation, switching capacitor banks automatically according to grid power factor.
- Same Series Capacitor Contactor Comparison (400V/50Hz)
| Modelo | Matched Capacitor Capacity | Voltaje de la bobina | Escenario de aplicación |
| LC1DWK12p7 | 63kVAR | 230V y | industrias generales & commercial compensation |
| LC1DWK12M7 | 63kVAR | 220V y | Standard for Asian market |
| LC1DWK12U7 | 63kVAR | 240V y | Standard for North American market |
| LC1DWK09p7 | 40kVAR | 230V y | Small compensation systems |
- Consideraciones clave de selección
- Capacitor capacity matching: 63kVAR for 400V system, 60kVAR for 415V system, 80kVAR for 575V system.
- voltaje de la bobina: Voltaje del circuito de control de fósforo (230V/220V/240V AC).
- Frecuencia de funcionamiento: ≤240 cycles/hour to meet dynamic compensation requirements.
- Environmental conditions: Wide-temperature type suitable for outdoor and harsh industrial environments.
Core Product Advantages of LC1DWK12p7 Schneider Capacitor Switching Contactor
As a dedicated capacitor contactor in the Schneider TeSys D series, LC1DWK12p7 is designed for 63kVAR/400V three-phase capacitor switching. Its core advantages focus on four aspects: inrush current suppression, high-frequency reliability, wide environmental adaptability, compliance and easy maintenance, delivering outstanding professional performance compared with general-purpose contactors in reactive power compensation applications.
- Dedicated Capacitor Switching Design — Solve Inrush Current & Arc Problems Fundamentally
1.1 Pre-wired Damping Resistor + Early-make Auxiliary Contact (Core Patent Advantage)
Built-in current-limiting damping resistor: Suppresses capacitor inrush current up to 100 times the rated current during switching, protecting capacitors and contacts from overload impact.
Early-make auxiliary contact design: Ensures the damping resistor is connected to the circuit first, then the main contacts close, realizing inrush-free switching and greatly reducing contact ablation risk.
Special contact alloy: Adopts AgSnO₂ material with excellent arc resistance and welding resistance, perfectly adapting to high-frequency operation (arriba a 240 cycles/hour) and capacitive load characteristics.
1.2 Precise Capacity Matching
Rated for direct use with 63kVAR/400V/50Hz capacitors, enabling simple selection without complex calculation and avoiding damage caused by capacity mismatch.
Compatible with 690V systems (máximo. 104kVAR), offering strong voltage adaptability for various power distribution systems.
- Alta confiabilidad & Durability — Industrial-Grade Stable Operation
2.1 Ultra-long Mechanical & Electrical Lifespan
Vida mecánica: ≥10 millones de operaciones, far exceeding the standard of ordinary contactors.
vida electrica: ≥300,000 capacitor switching cycles, meeting long-term dynamic compensation demands.
Harsh environment resistance: Operating temperature range -25℃ ~ +60℃, Grado de protección IP20, suitable for high and low temperature industrial sites.
2.2 High-Frequency Operation Adaptability
Soporta hasta 240 switching cycles per hour, ideal for rapidly changing load scenarios such as electric arc furnaces and welding machines.
Optimized coil structure reduces temperature rise during high-frequency operation and extends service life.
2.3 Schneider Patented Process Enhancement
Core iron core with patent anti-rust technology, 5 times higher corrosion resistance for humid, salt-laden and harsh environments.
Exclusive sealing design for dustproof and moistureproof performance, reducing contact contamination and improving connection reliability.
- Fácil instalación & Maintenance — Lower Engineering & oh&M Costs
3.1 Tamaño compacto & Flexible Mounting
85mm de ancho (3-pole standard size), saving cabinet space and supporting high-density installation.
Compatible with NS 35/7.5 DIN rail mounting and screw fixing, adapting to various installation conditions.
Screw-type clamping terminals ensure reliable connection and convenient wiring and maintenance.
3.2 Intelligent Diagnosis & Maintenance Prompt
Equipped with QR code identification for quick access to product manuals, installation guides and technical support, simplifying on-site maintenance.
Configuración de contactos auxiliares (1NO+2NC) supports status monitoring and fault alarm for remote diagnosis.
3.3 Low-Maintenance Design
Wear-part-free structure reduces maintenance frequency and lowers full-lifecycle cost.
Modular construction enables easy parts replacement and shortens downtime.
- Rendimiento eléctrico & Safety Compliance — Fully Meet Industrial Standards
4.1 Electrical Safety Design
Cumple con IEC 60947-4-1 y CEI 60831 (shunt capacitor standard), ensuring safe capacitor switching.
Mechanical interlock structure prevents misoperation and improves system safety.
Built-in coil overvoltage/undervoltage protection, adapting to grid voltage fluctuation and avoiding coil burnout.
4.2 Energy Efficiency Optimization
Low coil power consumption for energy-saving operation and long-term cost reduction.
Inrush-free switching design reduces grid harmonic pollution and improves overall power quality.
4.3 Certificaciones globales
Full certifications: CE, UL, CSA, CCC, CAO, Marine Approval for global application.
Green Premium product compliant with RoHS/REACH environmental standards, supporting sustainable development.
- System Integration Advantage — Perfectly Matches Reactive Power Compensation Solutions
5.1 Seamless Compatibility with Schneider Compensation Systems
Perfectly linked with Varlogic power factor controllers (VR6, VR12 series) to realize automatic compensation.
Matches with reactors (p.ej., Schneider VArSet series) to further suppress harmonics and inrush current.
Can be combined with TeSys D thermal relays and circuit breakers to build a complete capacitor protection loop.
5.2 Flexible Compatibility with Various Compensation Schemes
Supports Star / Delta capacitor wiring for different capacity and voltage level capacitor banks.
Applicable to static var compensation (SVC) and dynamic var compensation (SVG front-end) systems with wide application coverage.
- Core Difference Comparison with Ordinary Contactors
| Artículo de comparación | LC1DWK12p7 Capacitor Contactor | General-Purpose Contactor |
| Inrush Suppression | Built-in damping resistor + early-make contact, inrush-free switching | No dedicated design; inrush current up to 100 veces la corriente nominal, easy contact & daño del condensador |
| Material de contacto | Special AgSnO₂ alloy, arc & welding resistant | Ordinary silver alloy, short service life under capacitive load |
| Frecuencia de operación | Arriba a 240 cycles/hour for dynamic compensation | Normally ≤120 cycles/hour, easy overheating at high frequency |
| Capacity Matching | Directly marked 63kVAR/400V, simple selection | Requires complex calculation, prone to capacity mismatch |
| Protection Performance | Optimized for capacitor characteristics, sobre/subtensión & phase loss protection | General protection only, lacking targeted adaptation for capacitor switching |
- Profesional & Seguro: Specially designed for capacitor switching, eliminating inrush current and arc risks fundamentally to protect equipment.
- Alta confiabilidad: Wide temperature tolerance, high-frequency capability and long service life for harsh industrial environments and frequent switching.
- Fácil instalación & Mantenimiento: Estructura compacta, flexible mounting and intelligent O&M to reduce project and maintenance costs.
- Compatibilidad del sistema: Seamlessly integrated with Schneider compensation systems to simplify scheme design and commissioning.
- Global Certification: Fully compliant with international standards, adecuado para industrias, commercial and special scenarios with stable system operation guaranteed.
contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares