(X20 Compact-S Series CPU)
Descripción: X20 Compact-S compact fanless PLC controlador, ARM Cortex-A9 platform, integrated POWERLINK hard real-time bus, sin batería & sin mantenimiento, master controller for B&R Sistema de E/S distribuidas X20
- Explicación del código del modelo
X20: X20 family automation system
PC: Controller Processor
04: Compact-S compact ARM Cortex-A9 series
83: 500megahercio, 256MB memory, 1GB Flash, 32kB FRAM, integrated POWERLINK V2
- Especificaciones principales de hardware
| Artículo | Parámetro |
| Procesador | ARM Cortex‑A9 @500MHz with dedicated I/O processor |
| Memoria | 256 MB DDR3 SDRAM |
| Onboard Storage | 1 GB internal Flash; 32 kB FRAM (retentive variables for power loss, sin batería) |
| Enfriamiento | Diseño sin ventilador |
| Consumo de energía | Aprox.. 2.9W. |
| Onboard Interfaces | 1×10/100Mbps Ethernet |
| 1×POWERLINK V2 (supports PRC Poll Response Chain) | |
| 2×USB2.0 | |
| 1×RS232 | |
| Enlace X2X (X20 local I/O backplane bus) | |
| Ranuras de expansión | Arriba a 2 slots for X20 communication modules, RS485 opcional, CANopen and others |
| Software | Estudio de automatización, firmware upgradeable for V4.3 / V6.0 |
| Diagnóstico | LED status diagnosis for CPU, Ethernet, POWERLINK and temperature |
| Certificaciones | CE, UL/cULus, Reino Unido, ATEX Zona 2; Clase de protección IP20 |
| Temperatura de funcionamiento | Montaje horizontal: -25~+60℃; Montaje vertical: -25~+50 ℃ |
Key Highlights: Battery-free architecture. FRAM retains retentive variables, eliminating maintenance for battery replacement. POWERLINK PRC mode greatly reduces real-time communication cycle for multi-node motion control applications.
- Intra-family Comparison (X20CP048x)
X20CP0482: Cortex-A9@300MHz, 128MB RAM, 1GB Flash, 16kB FRAM
X20CP0483: Cortex-A9@500MHz, 256MB RAM, 1GB Flash, 32kB FRAM
X20CP0484: Cortex-A9@667MHz, 256MB RAM, 2GB Flash, 64kB FRAM
X20CP0484‑1: Cortex-A9@667MHz, 512MB RAM, 2GB Flash, 64kB FRAM
- Aplicaciones típicas
- Machine control: Maquinaria de embalaje, maquinas textiles, moldeo por inyección, small CNC machine tools
- Control de movimiento multieje: Paired with ACOPOS servo drives over POWERLINK real-time bus
- Standalone machine controller for production lines, test equipment and small automation workstations
- Control cabinets with limited installation space requiring maintenance-free and wide-temperature operation
- Instalación & Accesorios
- Mounted on X20 bus base unit. Base, power supply module and terminal blocks are ordered separately; CPU does not come with base.
- X2X Link backplane connects X20 digital / analog I/O modules
- Insert X20 communication modules into expansion slots for CAN, RS485 and other third-party bus extensions
- Programación & puesta en marcha: USB direct connection or Ethernet to download Automation Studio projects
- Pautas para la solución de problemas
- POWERLINK communication failure: Verify PRC configuration, resistencias terminales, node ID, cable shielding and grounding; diagnose link via status LEDs
- Boot failure: Flash partition corruption can be recovered by firmware reinstallation in AS; FRAM variable anomaly can be cleared by resetting retentive variables
- Over-temperature alarm: Check cabinet ventilation and mounting orientation; derating required for vertical installation
- Communication packet loss: Isolate Ethernet/POWERLINK; separate routing of strong and weak signal cables
- Selección alternativa
Downward alternative: X20CP0482 (lower computing power and memory for budget-limited projects)
Upward alternative: X20CP0484 (higher clock frequency, larger Flash & FRAM for complex multi-axis and large programs)
Cross-series option: X20CP1583 (legacy Atom platform with battery, no recomendado para nuevos diseños)
- Código HS
850440 (Electrical static converters, classification for PLC controllers)
- Program Migration Notes
- AS project version must match hardware firmware version (V4.3/V6.0). Back up project before firmware upgrade
- FRAM retentive variable address mapping differs from legacy battery-backed CPUs; retentive area needs redefinition during migration
- POWERLINK PRC parameters must be re-verified for bus cycle and timing after migration; ACOPOS servo axis configuration can be migrated
B&R X20CP0483 Programming Software Description
The only official development software: Estudio de automatización (COMO). No third-party standalone programming software supports this CPU.
X20CP0483 adopts ARM Cortex‑A9 Compact-S architecture. VC3 visualization is not supported. This is critical when migrating projects from legacy Intel-based CPUs.
- Supported AS Versions (HW Upgrade Hardware Package)
- AS V4.3: Earliest version supporting X20CP0483 (paired with Automation Runtime V4.x)
- AS V6.0: New stable release, recomendado para nuevos proyectos (paired with AR V6.x)
AS4.11 and later AS4.x subversions can load V4.3 hardware package; AS6.0 preferred for new developments
- IEC61131‑3 + C Programming Languages within AS
All developed inside the same Automation Studio project environment:
ST Structured Text (más utilizado, preferred for motion control)
Diagrama de bloques de funciones FUP
LD Ladder Diagram
SFC Sequential Function Chart
IL Instruction List (raramente usado)
C Language: Native C code support (ARM architecture; ARM compiled libraries required. x86 binary libraries cannot be used directly)
Supplementary packages: mapp libraries (mappMotion, mappIO, mappView HMI), reACTION high-speed I/O programming are all developed within AS.
- Descargar / Debug Methods (inside AS)
USB direct connection for debug and download
Ethernet TCP/IP online download
Offline update package for USB flash firmware update (no CF card, Compact-S exclusive)
- Important Limitations
- VC3 visualization unavailable: VC3 is designed for legacy x86 CPUs (p.ej. X20CP1483). mappView must be used for HMI on ARM-based X20CP0483
- Third-party compiled libraries (APLib): ARM version required. x86 binaries cannot be loaded; source code needs recompilation
- No standalone programming software; Codesys, GX Works and other PLC software cannot program this controller directly
- Auxiliary Tools (not IDE)
Runtime Utility Center (RUC): Image backup and restoration
Built-in AS tools: Configuración de hardware, POWERLINK setup, motion axis configuration, online diagnosis, variable monitoring, simulación
B&R Automation Studio (COMO) Guía de instalación (for X20CP0483, recommended AS V6.0 / AS V4.3)
Importante: AS runs on Windows x86/x64 PCs. Not supported on Mac/ARM laptops. Separate HW Upgrade hardware package required to use X20CP0483.
- Pre-install Requirements
- Sistema operativo (64-bit recommended)
AS V4.3: Win10 64-bit (Win7 SP1 also supported, not recommended now)
AS V6.0: Win10/Win11 64-bit
No compatible: Lightweight/cut-down Windows Home editions; virtual machines may have network/licensing issues; do not install on runtime industrial PCs
- PC Hardware
UPC: i5 or higher, RAM ≥8GB (16GB recommended for large projects + simulación)
disco duro: Minimum 20GB free space (main software + hardware packages + mapp libraries + project cache)
Red: Wired Ethernet preferred; USB port for CPU debugging
Prerequisite components: .NET Framework 4.8, VC++ runtime libraries. Included in installer and deployed automatically
- Software Acquisition
Download installation packages from B&R official website after login:
AS V4.3: Earliest version supporting X20CP0483
AS V6.0: Preferred for new projects, stable release
Package is ZIP archive. Extract path no Chinese characters or spaces
- Full Installation Steps
- Extract installation package
Extract to pure English path, p.ej. D:\B&R\AS6.0; No Chinese folders, otherwise installation errors.
Right-click Setup.exe → Run as administrator.
- Launch installation wizard
Accept license agreement
Tipo de instalación: Completo (recomendado); custom setup can remove unused translation documents
Install path: Suggest C:\Program Files\B&R\Automation Studio 6.0, keep default C:\ path if possible
Wait for main program installation. CodeMeter license driver, .NET and C++ runtimes will be installed automatically
- Install HW Upgrade hardware package after main installation (Crítico! X20CP0483 will not appear without this)
Main AS software does not contain hardware catalog. HW Upgrade is mandatory to recognize X20CP0483
- Download matching HW Upgrade from B&sitio web R (V4.x HW package for AS V4.3; V6.x HW package for AS V6.0)
- Right-click HW Upgrade installer AS6_HW_xxxx.exe, ejecutar como administrador
- Wizard auto-detects installed AS, follow prompts
- Después de la instalación, open AS and X20CP0483 will be available in hardware catalog
- Install mapp libraries (opcional, required for motion control and mappView HMI)
mapp libraries are separate installers, also run as administrator.
- Software Licensing (CodeMeter)
AS runs in 90-day trial mode without activation. 3 licensing options:
- Online activation (internet-connected PC)
Open AS → Help → License → Enter B&R License Key for online activation. License saved into CodeMeter container (soft license CmActLicense).
- Offline activation (office PC without internet, common in industrial environments)
Generate license request file .wbb on local PC
Copy file to internet-connected PC, upload request file on B&R licensing portal
Obtain returned license file, copy back and double-click to import and activate locally
- USB hardware dongle CmDongle (USB stick, convenient for switching between multiple PCs for site commissioning)
Trial license: Apply for 90-day free trial license on B&sitio web R, renewable. Formal license required for commercial projects; mapp library and mappMotion motion libraries are licensed separately, not included in base AS license.
- New Project Verification for X20CP0483
- Open Automation Studio → New Project
- Hardware configuration → Add CPU. Select X20CP0483 under X20 Compact-S catalog
✅ CPU selectable = HW package installed successfully; ❌ CPU missing = mismatched HW Upgrade version or missing hardware package
- Configure X2X backplane, POWERLINK and Ethernet, then programming, simulation and download can start
- Errores comunes de instalación
- Chinese characters or spaces in paths: Extract, install and project folders must use English names only, otherwise compile failure or hardware catalog loading error
- Missing HW Upgrade: Only main AS installed, X20CP0483 cannot be found in new project. This accounts for 90% of such issues
- Antivirus blocking CodeMeter: Temporarily disable 360/Huorong before installation; blocked CodeMeter service causes AS startup license error
- Version mismatch: AS V4.x HW package cannot be installed with AS V6.0, versions must match
- Legacy software residue: If old AS versions were previously installed, clean registry after uninstall to avoid new install failure
- Uninstallation
Uninstall Automation Studio in Control Panel; then uninstall CodeMeter Runtime; manually delete residual project folders.
- Communication Preparation after Installation for X20CP0483 Commissioning
- Set PC Ethernet IP within the same subnet as CPU IP
- Or connect USB cable directly to CPU USB port, scan controller in AS Target Browser
- Online project download, firmware upgrade and diagnostics
B&R X20 Compact-S (X20CP04xx) Full CPU Model List
- Model Groups
- Modelos básicos (without POWERLINK): X20CP0410 / 0411 / 0420
- Motion models (with integrated POWERLINK, X20CP0483 belongs to this group): X20CP0482 / 0483 / 0484 / 0484-1
- Conformal coated models (X20cCP04xx, anti-condensation & corrosive gas resistant)
- Full Standard Model List (Non-coated)
Basic Economy Models (No POWERLINK)
| Modelo | Reloj | RAM / Destello | FRAM | Interfaces clave |
| X20CP0410 | 166 megahercio | 128MB RAM / 256MB Flash | 8kB | Ethernet+RS232+USB |
| X20CP0411 | 240 megahercio | 128MB RAM / 512MB Flash | 16kB | Ethernet+RS232+USB |
| X20CP0420 | 166 megahercio | 128MB RAM / 256MB Flash | 8kB | Ethernet de doble puerto (integrated switch)+RS232+USB |
Motion Control Models (POWERLINK integrado)
| Modelo | Reloj | RAM / Destello | FRAM | Especificaciones clave (X20CP0483 family) |
| X20CP0482 | 300 megahercio | 128MB RAM / 1GB Flash | 16kB | POWERLINK+ Ethernet+RS232+USB |
| X20CP0483 | 500 megahercio | 256MB RAM / 1GB Flash | 32kB | POWERLINK+ Ethernet+RS232+USB |
| X20CP0484 | 667 megahercio | 256MB RAM / 2GB Flash | 64kB | POWERLINK+ Ethernet+RS232+USB |
| X20CP0484-1 | 667 megahercio | 512MB RAM / 2GB Flash | 64kB | High memory version, POWERLINK standard |
- Conformal Coated Models (X20cCP04xx for high humidity/corrosive environment)
Direct counterparts of above, prefix changed to X20c:
X20cCP0410
X20cCP0411
X20cCP0420
X20cCP0482
X20cCP0483
X20cCP0484
X20cCP0484-1
- Reglas de nomenclatura de modelos
- 041incógnita: Standard PLC without POWERLINK, cost-effective series
- 0420: Standard PLC with integrated dual-port Ethernet switch, no POWERLINK
- 048incógnita: Motion CPU, onboard POWERLINK bus for ACOPOS servo drives (X20CP0483/0484)
- Higher suffix number: higher clock speed, larger RAM/Flash and FRAM
- Sufijo -1: Memory enhanced variant (0484-1 doubles RAM compared to 0484)
- Matching Base Units (Ordenado por separado)
X20BB52 / BB53: for X20CP0410/0411/0420
X20BB62 / BB67, X20BB72 / BB77: for POWERLINK models X20CP0482/0483/0484
contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor