Chint NXBLE63 – 2P/C40

Chint NXBLE63 – 2P/C40 is a 2 – polo (2PAG) miniature residual current circuit breaker. Its main parameters and functions are as follows: Core Parameters Rated Current: 40A (“C40” indicates that the tripping characteristic is Type C and the rated current is 40A); Número de polo: 2PAG (cuts off both the live wire and the neutral wire ...

  • Detalles del producto

Chint NXBLE63 – 2P/C40 is a 2 – polo (2PAG) miniature residual current circuit breaker. Its main parameters and functions are as follows:

Parámetros principales

Corriente nominal: 40A (“C40” indicates that the tripping characteristic is Type C and the rated current is 40A);

Número de polo: 2PAG (cuts off both the live wire and the neutral wire simultaneously);

Protección de corriente residual: tipo de CA (detects ordinary AC leakage). The residual operating current is usually 30mA (an industry conventional value, and some models support options such as 50mA/75mA);

Capacidad de ruptura: 6el (can safely cut off circuits with a short – circuit current of not less than 6000A);

Voltaje aplicable: 230V (for single – circuitos de fase);

Mechanical/Electrical Life: The mechanical life is 20,000 veces, y la vida eléctrica es 10,000 veces.

Funciones principales

  1. Protección de corriente residual: When there is electric shock to the human body (current ≥ 30mA) or equipment leakage in the circuit, the power supply is quickly cut off within 0.1 second to prevent electric shock casualties;
  2. Protección contra sobrecarga: If the circuit load is too large (current exceeds 40A), it will automatically disconnect to avoid overheating and fire of the circuit;
  3. Corto – Protección de circuito: Cuando ocurre un cortocircuito en el circuito. (current increases sharply in an instant), the circuit is cut off immediately to protect electrical appliances and the circuit;
  4. Función de aislamiento: It can be used as a switch for infrequent on – off of the circuit under normal conditions.

Escenarios de aplicación

Electricidad Doméstica: For high – power socket circuits in kitchens, salas de estar, etc.. (como aires acondicionados, calentadores de agua electricos), it replaces traditional air switches and adds residual current protection;

Pequeño – scale Commercial Places: For socket or lighting circuits in convenience stores and offices, meeting the electricity demand within 40A;

Decoration and Renovation: Upgrading the residual current protection of old circuits to meet the new national standard’s requirement that “socket circuits must be equipped with residual current protection”.

Installation and Use Precautions

– It should be selected according to the actual load of the circuit to avoid “a big horse pulling a small cart” o “un caballo pequeño tirando de un carro grande”;

– Presione el “botón de prueba (T key)” once a month to verify whether the residual current protection function is normal;

– Al instalar, the live wire (l) y el cable neutro (norte) must be distinguished. If the wiring is reversed, the residual current protection function may fail.