GV3P80 is a 3‑pole thermal‑magnetic motor circuit breaker from Schneider Electric TeSys GV3 series. It has an adjustment current range of 70–80A, suitable for 45kW (400V) / 55kilovatios (690V) three‑phase motors. It integrates triple protection (sobrecarga, short‑circuit, falla de fase) and isolation function, serving as a core protection component in industrial motor circuits. Model Explanation GV3: ...

  • Detalles del producto

GV3P80 is a 3‑pole thermal‑magnetic disyuntor de motores from Schneider Electric TeSys GV3 series. It has an adjustment current range of 70–80A, suitable for 45kW (400V) / 55kilovatios (690V) three‑phase motors. It integrates triple protection (sobrecarga, short‑circuit, falla de fase) and isolation function, serving as a core protection component in industrial motor circuits.

  1. Model Explanation

GV3: TeSys GV3 motor circuit breaker series (frame size 3)

PAG: Thermal‑magnetic release (triple protection: sobrecarga + short‑circuit + falla de fase)

80: Rated current 80A, adjustable range 70–80A (continuously adjustable)

  1. Key Specifications (Full Data)
ArtículoEspecificación
polacos3PAG (three‑phase)
Adjustment current range70–80A (continuously adjustable)
Trip typeTermomagnético
Short‑circuit trip multiplier14×In (1120A)
Breaking capacity Icu65kA @ 230V; 50kA @ 400V; 6kA @ 690V
Tensión asignada de empleo Ue690V CA 50/60 Hz
Insulation voltage Ui690V y
Impulse withstand voltage Uimp6kV
Suitable motor power45kW @ 400V; 55kW @ 690V; 22kW @ 230V
TerminalesEverLink screw terminals (25–35mm² cable)
MontajeCarril DIN (width 55mm), screw mountable
Degree of protectionIP20 (frente)
Temperatura de funcionamiento-20°C ~ +60°C (derating factor: 0.8 at +60°C)
Resistencia mecánica50,000 operating cycles
Resistencia eléctrica20,000 ciclos (category AC‑3)
Función de aislamientoComplies with IEC 60947‑1, can be used as safety isolator
CertificacionesCCC, CE, UL, CSA, IEC 60947‑4‑1
PesoAprox.. 1.02 kilos
Dimensiones (Ancho×Alto×Profundidad)55 × 105 × 78 milímetros
  1. Funciones principales & Ventajas
  2. Triple Protection

Thermal trip: Overload inverse‑time protection (simulates motor heating characteristics)

Magnetic trip: Short‑circuit instantaneous protection (fixed 14×In)

Protección contra fallo de fase: Automatic trip under three‑phase unbalance (IEC 60947‑4‑1)

  1. EverLink Terminal Technology

Maintenance‑free, anti‑loosening, oxidation‑resistant, suitable for large‑section cables, reduces wiring failure risks.

  1. Diseño de seguridad

Knob operation, lockable in OFF position (arriba a 3 padlocks)

Clear current scale for precise adjustment

Complies with IEC isolation standards, usable as motor circuit isolator

  1. Wide Environmental Adaptability

Operating altitude: ≤3000m (no derating required)

Vibration resistance: 10–150Hz, 0.5mm amplitude

Shock resistance: 5Gn (11EM); 30Gn (1EM)

  1. Selection Reference (TeSys GV3 Series)
ModeloAdjustment CurrentSuitable Power (400V)Tipo de viajeCaracterísticas
GV3P6555–65A37kilovatiosTermomagnéticoEstándar, EverLink terminals
GV3P8070–80A45kilovatiosTermomagnéticoThis model, max adjustment current
GV3L8070–80A45kilovatiosMagneticShort‑circuit protection only
GV3ME8040–80A45kilovatiosTermomagnético3‑step adjustment (40–50/63–80), economy version
GV3P4030–40A22kilovatiosTermomagnéticoFor small‑medium motors
  1. Applications

Direct starting / star‑delta starting circuits for three‑phase asynchronous motors

Main circuit protection for fans, zapatillas, compresores, transportadores, maquinas herramientas

Industrial automation lines, construction equipment motor control

Motor circuits requiring isolation and safety interlock (p.ej., emergency stop loops)

Motors with frequent starting/stopping and fluctuating loads

  1. Replacement Options
  2. Schneider same series

GV3L80 (short‑circuit only, lower cost)

GV3ME80 (simplified adjustment, same mounting space)

  1. Competitor alternatives

siemens: 3RV1041‑4JA10 (70–80A, 3PAG, termomagnético)

TEJIDO: MS165‑80 (70–80A, 3PAG, termomagnético)

Chinese brands: Chint NM1‑125S, Delixi CDM1‑125 (motor protection curve matching required)

  1. Upgrade solution

Schneider GV4P08N (frame 4, mayor capacidad de rotura, for motors above 55kW)

Consejos de selección

  1. Select adjustment range at 1.1–1.25 × motor rated current
  2. Confirm breaking capacity meets system short‑circuit current requirements
  3. For isolation function, prefer models with certified isolation
  4. For limited wiring space, choose EverLink terminal models to reduce faults

Complete Model List of Schneider Electric TeSys GV Series Motor Circuit Breakers

Schneider TeSys GV series motor circuit breakers include six sub‑series: GV1, GV2, GV3, GV4, GV5, GV6, covering an adjustment range from 0.06A to 800A, suitable for 0.03kW to 400kW (400V) three‑phase motors, with thermal‑magnetic, magnetic, and economy thermal‑magnetic protection types.

  1. GV1 Series (Miniature, discontinued, replaced by GV2ME)

GV1ME01: 0.1–0.16A

GV1ME02: 0.16–0.25A

GV1ME03: 0.25–0.4A

GV1ME04: 0.4–0.63A

GV1ME05: 0.63–1.0A

GV1ME06: 1.0–1.6A

GV1ME07: 1.6–2.5A

GV1ME08: 2.5–4.0A

  1. GV2 Series (Pequeño, 0.06–16A, 0.03–15kW/400V)

2.1 GV2P (Termomagnético, full protection, knob)

ModeloAdjustment CurrentSuitable Power (400V)
GV2P010.1–0.16A0.06kilovatios
GV2P020.16–0.25A0.12kilovatios
GV2P030.25–0.4A0.2kilovatios
GV2P040.4–0.63A0.37kilovatios
GV2P050.63–1.0A0.55kilovatios
GV2P061.0–1.6A0.75kilovatios
GV2P071.6–2.5A1.5kilovatios
GV2P082.5–4.0A2.2kilovatios
GV2P104.0–6.3A3kilovatios
GV2P146.3–10A4kilovatios
GV2P1610–16A7.5kilovatios

2.2 GV2L (Magnetic, short‑circuit only, knob)

ModeloAdjustment CurrentSuitable Power (400V)
GV2L010.1–0.16A0.06kilovatios
GV2L020.16–0.25A0.12kilovatios
GV2L030.25–0.4A0.2kilovatios
GV2L040.4–0.63A0.37kilovatios
GV2L050.63–1.0A0.55kilovatios
GV2L061.0–1.6A0.75kilovatios
GV2L071.6–2.5A1.5kilovatios
GV2L082.5–4.0A2.2kilovatios
GV2L104.0–6.3A3kilovatios
GV2L146.3–10A4kilovatios
GV2L1610–16A7.5kilovatios
GV2L2014–20A11kilovatios
GV2L2218–25A15kilovatios

2.3 GV2ME (Economy thermal‑magnetic, pushbutton, 3‑step)

ModeloAdjustment CurrentSuitable Power (400V)
GV2ME010.1–0.16A0.06kilovatios
GV2ME020.16–0.25A0.12kilovatios
GV2ME030.25–0.4A0.2kilovatios
GV2ME040.4–0.63A0.37kilovatios
GV2ME050.63–1.0A0.55kilovatios
GV2ME061.0–1.6A0.75kilovatios
GV2ME071.6–2.5A1.5kilovatios
GV2ME082.5–4.0A2.2kilovatios
GV2ME104–6.3A3kilovatios
GV2ME146.3–10A4kilovatios
GV2ME1610–16A7.5kilovatios

2.4 GV2LE (Magnetic with electronic trip, special applications)

GV2LE01 ~ GV2LE22: matching current ratings as GV2L, with electronic trip

  1. GV3 Series (Medio, 9–80A, 5.5–45kW/400V, 55mm de ancho)

3.1 GV3P (Termomagnético, full protection, EverLink)

ModeloAdjustment CurrentSuitable Power (400V)
GV3P139–13A5.5kilovatios
GV3P1813–18A11kilovatios
GV3P2518–25A15kilovatios
GV3P3223–32A18.5kilovatios
GV3P4030–40A22kilovatios
GV3P5040–50A30kilovatios
GV3P6555–65A37kilovatios
GV3P7365–73A45kilovatios
GV3P8070–80A45kilovatios

3.2 GV3L (Magnetic, short‑circuit only)

GV3L25: 18–25A

GV3L32: 23–32A

GV3L40: 30–40A

GV3L50: 40–50A

GV3L65: 55–65A

GV3L80: 70–80A

3.3 GV3ME (Economy thermal‑magnetic, 3‑step)

ModeloAdjustment CurrentSuitable Power (400V)
GV3ME4040–50A30kilovatios
GV3ME6350–63A37kilovatios
GV3ME8040–80A (3 pasos: 40–50/63–80)45kilovatios
  1. GV4 Series (Grande, 25–115A, 15–55kW/400V, 81mm de ancho)

4.1 GV4P (Termomagnético, full protection)

ModeloAdjustment CurrentSuitable Power (400V)
GV4P2525–32A18.5kilovatios
GV4P4032–40A22kilovatios
GV4P5040–50A30kilovatios
GV4P6350–63A37kilovatios
GV4P8063–80A45kilovatios
GV4P10080–100A55kilovatios
GV4P115100–115A55kilovatios

4.2 GV4L / GV4LE (Magnetic type)

GV4L25 ~ GV4L115: matching current ratings as GV4P

GV4LE25 ~ GV4LE115: magnetic with electronic trip

4.3 Special GV4 Models

GV4PB80S: UL489 approved, 63–80A

GV4P02N: 2‑pole thermal‑magnetic, special applications

  1. GV5 / GV6 Series (Extra‑large, 100–800A, 55–400kW/400V)

GV5P100: 80–100A

GV5P125: 100–125A

GV5P160: 125–160A

GV5P200: 160–200A

GV6P250: 200–250A

GV6P315: 250–315A

GV6P400: 315–400A

GV6P500: 400–500A

GV6P630: 500–630A

GV6P800: 630–800A

 

  1. Reglas de nomenclatura de modelos
Letter/NumberSignificado
GVTeSys GV series motor circuit breaker
1/2/3/4/5/6Frame size (1 = smallest, 6 = largest)
PAGThermal‑magnetic trip (sobrecarga + short‑circuit + falla de fase)
lMagnetic trip (short‑circuit only)
MEEconomy thermal‑magnetic trip (3‑step, cost‑optimized)
LEMagnetic trip with electronic functions
NumberCalificación actual (p.ej., 80 = 70–80A)
  1. Guía de selección rápida
  2. Select adjustment range at 1.1–1.25 × motor rated current
  3. For full protection (sobrecarga + short‑circuit + falla de fase): choose P series
  4. If thermal protection exists (p.ej., VFD): choose L series (short‑circuit only)
  5. Cost‑sensitive, simple adjustment: choose ME series (3‑step)
  6. Small motors (≤15kW): GV2; medio (15–45kW): GV3; grande (≥55kW): GV4–GV6
  7. Notas
  8. All models are 3‑pole (3PAG) for three‑phase asynchronous motors
  9. Protection characteristics comply with IEC 60947‑4‑1
  10. Capacidad de ruptura: GV2/GV3 100kA@400V; GV4 65kA@400V
  11. Montaje: 35carril DIN estándar mm
  12. Degree of protection: IP20 (front operating part)

Anterior: