Schneider MCCB CVS250F-3P-250A - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

Schneider MCCB CVS250F-3P-250A - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

cortacircuitos/

Schneider MCCB CVS250F-3P-250A

Full Model Interpretation Model Part Description Details CVS Product Series EasyPact CVS series MCCB, for distribution protection and motor protection 250 Frame Current 250A frame size, suitable for rated current range 100~250A F Breaking Capacity Class 36kA@415V AC, capacidad de ruptura estándar (N=50kA, H=70kA optional) 3P Number of Poles 3-pole circuit breaker, para protección de circuitos trifásicos ...

  • Detalles del producto
  1. Full Model Interpretation
Parte del modeloDescripciónDetalles
CVSSerie de productosEasyPact CVS series MCCB, for distribution protection and motor protection
250Marco actual250A frame size, suitable for rated current range 100~250A
FClase de capacidad de ruptura36kA@415V AC, capacidad de ruptura estándar (N=50kA, H=70kA optional)
3PAGNúmero de polos3-disyuntor de polos, para protección de circuitos trifásicos
250ACorriente nominalRated operational current 250A (a 40 ℃), adjustable thermal‑magnetic trip 175~250A
TM-DTipo de unidad de disparoViaje termomagnético (MT), D‑type adjustable (long‑time delay adjustable)
LV525333Official Part NumberStandard SKU corresponding to CVS250F-3P-250A
  1. Especificaciones técnicas clave
ArtículoValorNotas
Tensión nominal (Ui/Ue)690V/415V AC 50/60HzCompatible with global mainstream voltage systems
Corriente nominal (Iu/In)250A/250A (40℃)Thermal‑magnetic trip adjustable range: 175~250A
Capacidad de ruptura (Icu/Ics)36kA/36kA (415V)Ics=100%Icu; 70kA@220/240V AC
Tensión nominal de resistencia al impulso (árbitro)8kVComplies with EN/IEC 60947-2
Instantaneous Trip Current (yo)2000AFixed value for short‑circuit protection
Mechanical/Electrical Endurance20,000 / 10,000 operacionesAt 415V In, cumple con IEC 60947-2
Degree of ProtectionIP40Dust‑tight and splash‑proof, adecuado para entornos industriales
Tipo de conexiónCableado frontal / Cableado traseroFlexible for various installation requirements
Dimensiones (Ancho×Alto×Profundidad)105×226×86mmDiseño compacto, saves panel space
Pollution Class3Suitable for industrial pollution conditions
  1. Core Product Advantages
  2. Protección Integral: Thermal‑magnetic trip provides long‑time overload protection and instantaneous short‑circuit protection; long‑time delay adjustable (Ir=0.7~1.0In) for various load characteristics.
  3. High‑Reliability Breaking: 36kA high breaking capacity, Ics=100%Icu, ensures reliable fault interruption and equipment safety.
  4. Instalación flexible: Supports front/rear wiring; 3P/4P available, adaptable to different switchboard layouts.
  5. Eco‑Compliant: Green Premium certified, Cumple con RoHS, free of hazardous substances, meets sustainable development requirements.
  6. Fácil mantenimiento: Diseño modular, replaceable trip unit, convenient for maintenance and upgrade, reduces lifecycle cost.
  7. Enhanced Safety: Standard isolation function, improves operational safety, cumple con IEC 60947-2 isolation requirements.
  8. Operating Principle

CVS250F-3P-250A uses thermal‑magnetic tripping protection:

  1. Protección contra sobrecarga (Long Time Delay): Bimetal strip bends under heat and triggers the trip mechanism. Delay decreases as current increases; Ir adjustable 175~250A.
  2. Short‑circuit Protection (Instantáneo): Electromagnetic coil generates strong magnetic force, attracts armature and triggers instant trip at fixed 2000A without delay.
  3. Característica de disparo: Cumple con IEC 60947-2, Category A for distribution protection, protects cables and equipment against overload and short‑circuit damage.
  4. Aplicaciones típicas
  5. Distribución de energía industrial: Main protection for three‑phase power equipment in factories and workshops, such as air compressors, zapatillas, fans.
  6. Edificios Comerciales: Distribution mainline protection for offices, centros comerciales, hoteles, ensuring power continuity.
  7. Centros de datos: Power protection for UPS systems and server racks, preventing overload/short‑circuit impact on critical loads.
  8. Infraestructura: Electrical system protection for hospitals, escuelas, instalaciones publicas, ensuring public safety.
  9. Energía Renovable: AC‑side protection for PV inverters and energy storage systems, suitable for new energy applications.
  10. Instalación & Pautas de operación
  11. Ambiente: Install in dry area below 40℃, evitar la humedad, corrosion, vibración; max installation altitude 2000m.
  12. Alambrado: Use copper/aluminum conductors suitable for 250A (≥95mm² copper recommended), torque per Schneider specifications.
  13. Coordinación de Protección: Coordinate with downstream breakers/fuses to ensure selective protection and avoid non‑selective tripping.
  14. Configuración: Adjust long‑time delay current Ir (175~250A) according to load for accurate protection.
  15. Mantenimiento: Regularly check mechanism and terminals for looseness or overheating; full inspection at least once per year.
  16. Series Models & Alternativas

7.1 Full Model List – CVS250F Series (250un marco)

ModeloTipo de viajeCorriente nominalAdjustable RangeOfficial SKU
CVS250F-3P-160ATM-D160A112~160ALV525331
CVS250F-3P-200ATM-D200A140~200ALV525332
CVS250F-3P-250ATM-D250A175~250ALV525333
CVS250F-3P-150AMAMÁ150AFijadoLV525439
CVS250F-3P-220AMAMÁ220AFijadoLV525439
CVS250F-4P-250ATM-D250A175~250ALV525334

7.2 Reemplazo & Opciones de actualización

DemandModelo recomendadoCaracterísticas
Standard UpgradeCVS250N-3P-250ABreaking capacity up to 50kA, for high short‑circuit risk
Electronic TripCVS250F-3P-250A ETSElectronic trip unit with short‑time delay for critical loads
Protección contra fallas a tierraCVS250F-3P-250A VigiWith Vigi residual current module (30mA~5A adjustable)
Alternativa DomésticaCHINT NM1-250S/3300-250A36kA rompiendo, rentable, similar performance
Alternativa ABBTmax T2N250-3P-250AInternational brand, desempeño cercano, global service

CVS250F-3P-250A is a core product of Schneider EasyPact CVS series, integrating reliable protection, flexible installation and high cost‑performance. It is an ideal solution for industrial and commercial power distribution.

With 36kA breaking capacity, adjustable thermal‑magnetic trip and compact design, it adapts to a wide range of applications and safeguards both equipment and personnel.

Core Features of Schneider MCCB CVS250F-3P-250A

  1. Excellent Protection Performance
  2. Precise Thermal‑Magnetic Protection System

Adopts TM‑D adjustable thermal‑magnetic trip, long‑time protection range 175~250A (0.7~1.0In), suitable for various loads.

Fixed instantaneous short‑circuit trip at 2000A, fast fault interruption without delay, protects equipment from damage.

Cumple con IEC 60947-2 Category A for distribution, effectively protects cables and equipment.

  1. Reliable Breaking Capacity

36kA@415V AC (Clase F), Ics=100%Icu, ensures reliable fault interruption.

Up to 70kA at 220/240V AC, suitable for different voltage systems.

Double‑break arc extinguishing system improves current limitation and reduces thermal stress on the network.

  1. Comprehensive Safety Features
  2. Standard Isolation Function

Cumple con IEC 60947-2 isolation requirements, can be used as a disconnecting device, improves operational safety.

Class II front panel, compatible with Class II switchboards without derating insulation.

  1. Seguridad operativa

Clear contact position indicator shows real‑time status.

Locking device available to secure in OFF position and prevent misuse.

| Protección IP40, adecuado para entornos industriales.

  1. Indicación de falla

Optional SDE fault trip indicator for fast troubleshooting.

Excellent coordination with downstream devices for selective protection, avoids total outage.

  1. Instalación flexible & Fácil mantenimiento
  2. Versatile Installation

Supports front / rear wiring for various panel layouts.

Compact dimensions 105×226×86mm, ahorra espacio en el gabinete.

Same mounting as ComPacT series, easy for system upgrade.

  1. Diseño modular

Replaceable trip unit for easy maintenance and upgrade, reduces lifecycle cost.

Clip‑on accessories, plug‑and‑play, no special tools required.

3P/4P available for three‑phase and three‑phase four‑wire systems.

  1. Efficient Maintenance

Vida mecánica 20,000 operaciones, electrical life 10,000 operaciones (415V In).

Universal accessories across series, reduce inventory cost.

Adjustable long‑time current without replacing the breaker.

  1. Alta confiabilidad & Durability
  2. Robust Mechanical Structure

Double‑break mechanism ensures high fault current limitation and stable performance.

| Shock and vibration resistant for harsh industrial environments.

Rated impulse withstand voltage 8kV, complies with EN/IEC 60947-2.

  1. Fuerte adaptabilidad ambiental

Rated ambient temperature 40℃, operating range -5℃~+60℃.

Suitable up to 2000m altitude without derating.

Pollution Class 3 for industrial conditions.

  1. Stable Electrical Performance

Rated insulation voltage 690V, operational voltage 415V, global compatibility.

Terminals accept copper/aluminum conductors, suitable for 95mm²+ cables for 250A.

Stable long‑term operation, low contact resistance, low power loss.

  1. Eco‑Compliance & Cost Efficiency
  2. Green Design

Green Premium certified, Cumple con RoHS, halogen‑free.

Low power consumption, supports energy saving.

  1. High Cost‑Performance

Balanced performance and cost, ideal for mass industrial and commercial use.

Low maintenance cost, alta confiabilidad, larga vida útil.

Universal accessories reduce total cost of ownership.

  1. Lifecycle Value

18‑month warranty.

Global service network for fast support.

Extensible with accessories (falla a tierra, contactos auxiliares, alarms).

  1. Key Application Adaptability
  2. Industrial Distribution: Main protection for pumps, fans, compressors with heavy‑duty starting.
  3. Edificios Comerciales: Main and sub‑main distribution for offices, malls, hoteles.
  4. Centros de datos: Protection for UPS, PDUs, and critical power branches.
  5. Infraestructura: hospitales, escuelas, public facilities requiring high safety and continuity.

As a core model of the Schneider EasyPact CVS series, CVS250F-3P-250A provides accurate protection, full safety, instalación flexible, high reliability and excellent cost‑performance, making it the preferred choice for industrial and commercial power distribution systems.

Anterior:

Próximo:

Deja una respuesta

Dejar un mensaje