HLPA03D723B is a general-purpose inverter from Danfoss Holip HLP‑A series, 3.7 kilovatios, 220 V three-phase/single-phase. It is suitable for constant-torque loads, with an overload capacity of 150% para 1 minute, built-in PID and simple PLC, ideal for industrial applications such as plastic extrusion and conveyors.
- Model Explanation
| Code | Meaning |
|---|---|
| HLP | Holip brand prefix |
| A | HLP‑A general series (optimized for constant torque) |
| 03D7 | Power code, corresponding to 3.7 kilovatios |
| 23 | Voltage code: 2=220 V, 3=three-phase (compatible with single-phase) |
| B | Hardware version/configuration (standard version) |
- Parámetros eléctricos clave
| Artículo | Especificación |
| Rated Power | 3.7 kilovatios |
| Voltaje de entrada | 220 V single/three-phase, 50 Hz (±15% wide voltage range) |
| Rated Input Current | Aprox.. 17 A |
| Corriente de salida nominal | 17 A (continuous) |
| Capacidad de sobrecarga | 150% para 1 min, 180% para 0.2 s |
| Output Frequency Range | 0.1~400 Hz (resolución 0.01 Hz) |
| Modo de control | Control V/F, built-in PID, simple PLC |
| Starting Torque | Arriba a 150% rated torque at 1 Hz |
| Cooling | Forced air cooling |
| Grado de protección | IP20 (keypad) |
| Applicable Motor | 3.7 kilovatios 220 V three-phase asynchronous motor |
| Standard Keypad | OP‑AB01 (remotely mountable) |
- Dimensiones & Electrical Specifications
3.1 Dimensiones físicas (Unit: milímetros)
| Artículo | Valor |
| Ancho (W.) | 125 |
| Height (h) | 210 |
| Depth (D) | 185 |
| Orificios de montaje | 4×φ5 (spacing: 100×190) |
| Peso | Aprox.. 2.8 kilos |
Mounting Requirements: Mount vertically. Leave ≥100 mm clearance above and below, ≥50 mm left and right for ventilation. Avoid dust, oil, and humidity.
3.2 Electrical Installation
| Component | Rating | Cable Size |
| Input Circuit Breaker (NFB) | 30 A | 4 mm² (cobre) |
| Input Contactor | 25 A | 4 mm² |
| Output Cable | 4 mm² (shielded recommended) | |
| Circuito de control | 1.5 mm² (shielded for signals) | |
| Grounding | ≥4 mm², grounding resistance ≤10 Ω |
- Alambrado & Terminal Definitions
4.1 Main Circuit Terminals
| Terminal | Función |
| R/L1, S/L2, T/L3 | 220 V power input (monofásico: connect R/L1, S/L2) |
| Ud., V, W. | Inverter output (to motor) |
| educación física | Protective earth (must be securely connected) |
4.2 Control Circuit Terminals (Estándar)
| Terminal | Descripción |
| DI1~DI5 | 5 entradas digitales (programmable: FWD, REV, multivelocidad) |
| DO1~DO2 | 2 salidas digitales (relé / open-collector optional) |
| AI1 | Entrada analógica (0~10 V/4~20 mA, programmable) |
| AO1 | Analog output (0~10 V, for frequency/current) |
| +10V | 10 V DC supply (max 50 mamá) |
| Tierra | Analog / digital common |
| RS485 | Communication port (Modbus RTU) |
Wiring Notes: Separate main power and control wiring. Use shielded cable for analog signals, grounded at one end. Avoid parallel routing with power cables.
- Características & Applications
Funciones principales
Built-in PID controller: Suitable for closed-loop control (presión, flow, temperatura)
Simple PLC: 16-step speed, program run, traverse function
Protección integral: sobrecorriente, sobretensión, subtensión, overheat, pérdida de fase, motor overload
Comunicación: RS485 standard, Modbus RTU, for centralized control
Aplicaciones típicas
Plastic extruders: Optimized for constant torque, stable low-speed high-torque operation
Conveyors: Smooth start, multivelocidad, load-adaptive
Mixers: High starting torque, strong overload capability
Maquinaria de embalaje: Precise speed control, positioning
- Reemplazo & Guía de selección
6.1 Same-Brand Upgrades
| Original | Reemplazo | Advantage |
| HLPA03D723B | Danfoss FC‑051P3K7T2E20H3B | Fully compatible, upgraded functions, Danfoss support |
| HLPA03D723B | Holip HLP‑A100 3.7 kilovatios 220 V | Same platform, parameter compatible |
6.2 Cross-Brand Equivalents
| Marca | Modelo | Key Match |
| Inovance | MD200S3.7B | 220 V 3.7 kilovatios, 17 A, Control V/F |
| Invt | CHF100A‑3R7G‑2 | 220 V 3.7 kilovatios, 17 A, built-in PID |
| Delta | VFD037E23A | 220 V 3.7 kilovatios, 17 A, torque boost |
Critical Replacement Notes
- Voltage match: Must be 220 entrada V
- Current match: Rated current ≥17 A
- Mounting match: Dimensions and cooling compatible
- I/O match: Analog/digital interfaces compatible
- Parameter transfer: Save old parameters, reconfigure per new manual
- Solución de problemas de fallas
| Código de falla | Meaning | Soluciones |
| OC | sobrecorriente | 1. Check motor load & insulation |
| 2. Increase acceleration time | ||
| 3. Verify motor-inverter match | ||
| OV | Sobretensión | 1. Increase deceleration time |
| 2. Add braking unit/resistor | ||
| 3. Check mains voltage | ||
| UV | Subtensión | 1. Check input voltage (≥187 V) |
| 2. Tighten power terminals | ||
| 3. Stabilize power supply | ||
| OH | Overheat | 1. Improve ventilation (≤40°C) |
| 2. Clean heatsink | ||
| 3. Check fan operation | ||
| GF | Ground Fault | 1. Check motor/cable insulation |
| 2. Ensure reliable grounding | ||
| 3. Eliminate leakage | ||
| OL | Sobrecarga del motor | 1. Reduce load |
| 2. Check motor rated current setting | ||
| 3. Increase torque boost |
- Instalación & Maintenance
8.1 Installation Standards
Vertical mounting, away from direct sunlight and heat sources
Temperatura ambiente: -10°C~40°C (derate above 40°C)
Humedad: 5%~95% (non-condensing)
Altitud: ≤1000 m (derate above 1000 metro)
8.2 Programa de mantenimiento
A diario: Check temperature, fan noise, unusual odors
Trimestral: Clean heatsink, tighten terminals
Yearly: Check capacitors, replace worn fan
8.3 Unidad de frenado
For quick stop / high inertia: external braking unit HBR‑03D7 (para 3.7 kilovatios)
Braking resistor: 50 Ω / 100 W. (adjust per application)
- Technical Specifications
Modelo: HLPA03D723B (HOLIP HLP‑A Series)
Rated Power: 3.7 kilovatios
Voltaje de entrada: 220 V Single/Three Phase, 50 Hz (±15%)
Corriente de salida nominal: 17 A
Capacidad de sobrecarga: 150%/1 min, 180%/0.2 s
Método de control: Control V/F, built-in PID, simple PLC
Starting Torque: 150% rated torque at 1 Hz
Dimensiones (Ancho×Alto×Profundidad): 125×210×185 mm
Peso: Aprox.. 2.8 kilos
Practical Troubleshooting for HLPA03D723B (3.7kW/220V)
- Fault Codes (Más común)
1.1 OC / sobrecorriente
Causas: Motor jam, shorted cable, fast acceleration, poor motor insulation
Soluciones:
- Check for seized motor or overload
- Increase acceleration time
- Inspect U/V/W cables for damage or short
- Run inverter without motor to isolate fault
1.2 OV / Sobretensión
Causas: Fast deceleration, high mains voltage, high-inertia load
Soluciones:
- Increase deceleration time
- Add external braking resistor (≈50Ω/100W)
- Check if input exceeds 250 V
1.3 UV / Subtensión
Causas: Bajo 220 V, loose wiring, pérdida de fase
Soluciones:
- Measure R/S/T voltage (no lower than 180 V)
- Tighten power terminals
- Monofásico: connect R & S only
1.4 OH / Overheat
Causas: Blocked vents, faulty fan, high ambient temp
Soluciones:
- Clean heatsink and fan
- Verify fan operation
- Maintain ≥10 cm clearance top/bottom
1.5 OL / Sobrecarga del motor
Causas: Heavy load, wrong motor parameters, low torque
Soluciones:
- Reduce load
- Check motor rated current setting
- Increase torque boost
1.6 GF / Ground Fault
Causas: Motor leakage, grounded cable, poor insulation
Soluciones:
- Test motor insulation
- Check output cable for grounding
- Secure PE connection
1.7 CE / Communication Error
Causas: RS485 interference, wrong wiring
Soluciones:
- Check A/B wiring polarity
- Use shielded cable, grounded at one end
- Route away from power cables
- Abnormal Operation (No Fault Code)
2.1 Keypad displays but motor does not run
Soluciones:
- Check if in terminal control, no start signal
- Verify DI1 (FWD) is closed
- Check frequency reference (0 V/0 mA)
2.2 Motor vibration / ruido
Soluciones:
- Lower carrier frequency
- Tighten motor cables
- Increase torque boost at low speed
2.3 Frequency cannot rise / limited
Soluciones:
- Check maximum frequency parameter
- Verify analog signal (0‑10 V/4‑20 mA)
- Check for false multi-speed input
- Important Notes for HLPA03D723B
220 V ONLY: DO NOT connect to 380 V (will damage IGBT module)
Arriba 3 fallas: OC, OV, UV
Single-phase input must be tightly secured; loose terminals often cause UV faults