P3U30-5AAA3BBAC is a general-purpose numerical integrated protection relay from the Schneider Electric Easergy P3 Series, also commonly referred to as a “numerical protection relay” or “protective relay device”. It is mainly used for the protection, control, measurement, and monitoring of feeders, transformadores, motores, and other equipment in medium‑ and low‑voltage power systems. In‑Depth Model Code ...

  • Detalles del producto

P3U30-5AAA3BBAC is a general-purpose numerical integrated protection relay from the Schneider Electric Easergy P3 Series, also commonly referred to as a “numerical protection relay” or “protective relay device”. It is mainly used for the protection, control, measurement, and monitoring of feeders, transformadores, motores, and other equipment in medium‑ and low‑voltage power systems.

  1. In‑Depth Model Code Analysis (Schneider P3 Series Standard Naming Convention)
Code SegmentMeaningDescripción
P3U30Basic ModelP3 = Easergy P3 Series; U = Universal Protection; 30 = 30TE standard size (aprox. 190×190 mm)
5Protection Configuration5 = Standard feeder protection package (including overcurrent, instantaneous, falla a tierra, reclosing, and other basic functions)
AAAMeasurement & Inputs1st A = 3CT (3 current transformer inputs); 2nd A = 1Io (1 residual current input); 3rd A = 4VT (4 voltage transformer inputs: 3 phases + neutral)
3Interfaz de comunicación3 = Dual RJ45 Ethernet ports (supports mainstream protocols such as Modbus TCP, CEI 61850)
BBDigital I/O1st B = 16DI (16 entradas digitales); 2nd B = 8DO (8 salidas digitales)
AAuxiliary Power SupplyA = Wide‑range 48–230 V AC/DC power supply (adapts to various on‑site power conditions)
doDigital Input VoltageC = 220–230 V AC/DC (rated voltage for digital input circuits)
  1. Parámetros técnicos básicos & Presupuesto

3.1 Parámetros eléctricos

Categoría de parámetroEspecificación
Auxiliary Power48–230 V AC/DC, 50/60 Hz, tolerance +10% / –15%
Entradas digitales (DE)16 canales, 220–230 V AC/DC, opto‑isolated, response time ≤ 1 EM
Salidas digitales (HACER)8 canales, relay outputs, contact rating 250 V y / 10 A or 24 En DC / 10 A
Entradas analógicas3 phase currents (Connecticut), 1 corriente residual (Io), 4 voltages (VT)
Measurement AccuracyCurrent/Voltage: Clase 0.2; Power/Energy: Clase 0.5

3.2 Funciones de protección (Feeder‑specific Configuration)

Protección contra sobrecorriente (IDMT / definite time selectable)

Instantaneous overcurrent protection (directional optional)

Earth fault protection (definite time / IDMT)

Auto‑reclosure function (multi‑shot optional)

Protección contra sobrecarga (alarma / trip selectable)

Voltage protection (sobretensión / subtensión / dead voltage)

Frequency protection (overfrequency / underfrequency)

Non‑electrical protection (accepts temperature, presión, etc.)

3.3 Communication Capabilities

Dual RJ45 Ethernet ports, supporting IEC 61850 ed.2, Modbus TCP, DNP3 TCP, EtherNet/IP

Optional RS485 serial port (Modbus RTU)

Supports network time synchronization (SNTP) and event recording (SOE, resolución 1 EM)

3.4 Características físicas

Dimensiones: 30TE standard (aprox. 190×190×180 mm)

Montaje: Flush mounting (panel mounting) or DIN‑rail mounting

Ingress Protection: IP40 (front), IP20 (overall)

Temperatura de funcionamiento: –25 °C to +70 °C; Storage temperature: –40 °C to +85 °C

Peso: aprox. 2.5 kilos

  1. Aplicaciones típicas
  2. Medium‑/Low‑Voltage Feeder Protection: 10 kV / 20 kV / 35 kV distribution feeders, enabling fast fault clearance and power restoration via auto‑reclosing
  3. Transformer Protection: Differential, sobrecorriente, temperature protection for distribution transformers (with matching CT/VT configuration)
  4. Motor Protection: Starting and running protection for HV motors, including stall, sobrecarga, pérdida de fase, falla a tierra, etc..
  5. Capacitor Bank Protection: sobrecorriente, sobretensión, unbalance protection for reactive compensation capacitor banks
  6. Sistemas de automatización industrial: Front‑end device for SCADA systems, providing accurate electrical measurement and equipment status monitoring
  7. Ventajas del producto & Características
  8. Modular Design: Protection functions flexibly configurable via software to suit various applications
  9. Alta confiabilidad: Based on Schneider Sepam, MiCOM, and Vamp platforms, compliant with strict EMC tests (IEC/EN 60255)
  10. Comprehensive Measurement: Real‑time monitoring of 30+ electrical parameters: actual, Voltaje, fuerza, energy, frecuencia, harmonics, etc..
  11. Flexible Communication: Supports multiple industrial protocols, easily integrated into smart grids and automation systems
  12. User‑friendly: Chinese UI, local keypad operation, remote network configuration, built‑in fault recording (1024 points per cycle)
  13. Modelos alternativos & Accessories

6.1 Modelos alternativos (Different Configurations in the Same Series)

Alternative ModelMain DifferencesSolicitud
P3U30-5AAA1BCAA1×RJ45 + 1×RS485, DI = 24 VLegacy system upgrades requiring RS485
P3U30-5AAA2BBABSingle RJ45, auxiliary power = 110 VSites with specific voltage levels, simplified configuration
P3U30-5AAA3BDAAAdded arc‑flash protectionFast protection for internal switchgear faults

6.2 Accesorios recomendados

Communication cable: UTP Cat5e/Cat6 for Ethernet

I/O modules: Expand DI/DO up to 32DI/16DO

HMI panel: Opcional, for local operation and data display

Test tool: Dedicated P3 series software for setting configuration and fault analysis

  1. Instalación & Operation Notes
  2. CT/VT Wiring: Strictly observe polarity to avoid maloperation or inaccurate measurement
  3. Power Supply: Ensure auxiliary power matches rating; surge protection recommended
  4. Comunicación: Assign static IP to avoid conflicts
  5. Setting Tuning: Set protection values appropriately according to on‑site equipment parameters
  6. Mantenimiento regular: Annual function test, accuracy calibration, and communication/version check recommended

As a mainstream model of the Schneider Easergy P3 Series, the P3U30-5AAA3BBAC is widely used in power system protection and monitoring in industrial, energy, and infrastructure fields. It is an ideal choice for the intelligent construction of medium‑ and low‑voltage power grids.

Complete Model Guide for Schneider Easergy P3 Series

(Including Full Range Related to P3U30-5AAA3BBAC)

The Schneider Easergy P3 Series numerical protection relays are divided into Standard (P3U) and Advanced (P3x) lines, covering feeders, transformadores, motores, generators, and other applications in medium‑/low‑voltage grids. All models are explained below by application, including key differences and suitable scenarios.

  1. Standard Universal Protection Relays (P3U Series)

Suitable for general feeders, motores, transformadores, cost‑effective and flexible.

ModeloTamañoFunciones principalesTypical ConfigurationSolicitud
P3U1010TE (96×96 mm)Basic overcurrent, no voltage measurementP3U10-5AAA1BBAASimple feeders
– 3CT+1Io, no VTSmall distribution circuits
– 1×RJ45Basic protection with limited budget
– 16DI/8DO
P3U2020TE (96×190 mm)Standard overcurrent + directional, with voltage measurementP3U20-5AAA2BBACDirectional feeders
– 3CT+1Io+4VTSmall/medium transformers
– 1×RJ45Applications requiring voltage monitoring
– 16DI/8DO
– 48–230 V AC/DC
P3U3030TE (190×190 mm)Full protection + complete measurement + advanced communicationP3U30-5AAA3BBAC (original)Complex feeders
P3U30-5AAA3BDAA (arc‑flash)Large transformers
Dual Ethernet redundancy
High‑precision measurement

P3U Series Model Code Supplement

Standard format: P3UXX-5AAA3BBAC

5th digit (5): Protection type: 5=feeder, 6=motor, 7=transformer

6th–8th (AAA): Analog inputs: AAA=3CT+1Io+4VT, ABA=4CT+1Io+3VT

9th (3): Comunicación: 1=1×RJ45+1×RS485, 2=1×RJ45, 3=2×RJ45

10th–11th (BB): I/O: BB=16DI/8DO, BC=24DI/12DO, BD=32DI/16DO

12th (A): Aux power: A=48–230 V AC/DC, B=110 V AC/DC, C=24 V DC

13th (do): DI voltage: C=220–230 V AC/DC, D=110 V AC/DC, E=24 V DC

  1. Advanced Specialized Protection Relays (P3x Series)

For dedicated high‑performance protection with built‑in algorithms.

2.1 Feeder‑specific Advanced Protection

ModeloTamañoFunciones principalesTypical ConfigurationSolicitud
P3F3030TEDirectional overcurrent + Voltaje + optional arcP3F30-CGGIA-AAEOAComplex feeders
– 4CT+4VTRing networks
– 2×RJ45+1×RS485Switchgear arc‑flash protection
– 22DI/13DO
P3L3030TELine differential + distance + directional overcurrentP3L30-LGGIA-AAEOALong transmission lines
– 6CT+4VTCritical lines
Dual IEC 61850Ring network differential
– 22DI/13DO

2.2 Motor‑specific Advanced Protection

ModeloTamañoFunciones principalesTypical ConfigurationSolicitud
P3M3030TEMotor protection + RTD temperatureP3M30-MGGIA-AAEOAHV motors
– 3CT+1Io+4VTCritical motors with temperature protection
– 16DI/8DO + RTD
Dual RJ45
P3M3230TEP3M30 + motor differentialP3M32-MGGIA-AAEOAmotores grandes (≥2000 kW)
– 6CT+4VTMotor‑transformer units
Differential module
– 22DI/13DO

2.3 Transformer‑specific Advanced Protection

ModeloTamañoFunciones principalesTypical ConfigurationSolicitud
P3T3230TETransformer differential + non‑electrical + backupP3T32-TGGIA-AAEOADistribution transformers
– 6CT+4VTPower transformers
WOG/pressure/temperature
– 22DI/13DO

2.4 Generator‑specific Advanced Protection

ModeloTamañoFunciones principalesTypical ConfigurationSolicitud
P3G3030TEGenerator protection + synchrocheckP3G30-GGGIA-AAEOASmall generators
– 3CT+1Io+4VTBackup generators
Frequency/voltage/sync
– 22DI/13DO
P3G3230TEGenerator differential + stator/rotor earthP3G32-GGGIA-AAEOALarge generators
– 6CT+4VTMain power generators
– 100% stator earth
Rotor earth
  1. Key Comparison Table (Related to P3U30-5AAA3BBAC)
ArtículoP3U10P3U20P3U30P3F30P3M32
Tamaño10TE20TE30TE30TE30TE
Max I/O16DI/8DO24DI/12DO32DI/16DO32DI/16DO32DI/16DO
ComunicaciónSingle Ethernet + SerialSingle EthernetDual EthernetDual + Dual SerialDual + Dual Serial
ProtecciónBasic overcurrentsobrecorriente + directionalFull + arc optionalDirectional + Voltaje + arcMotor differential + RTD
ExactitudClase 0.5Clase 0.5Clase 0.2Clase 0.2Clase 0.2
SolicitudSimple feederStandard feeder/transformerComplex feeder/transformerCritical feeder/ringLarge motor
  1. Model Selection & Replacement Guide
  2. By application

Simple distribution: P3U10

Standard feeder/motor: P3U20

Complex systems: P3U30 or advanced P3x

Critical lines/motors/transformers: P3L30 / P3M32 / P3T32

  1. Replacements for P3U30-5AAA3BBAC

Simplified: P3U30-5AAA2BBAB (single Ethernet, 110 V)

With RS485: P3U30-5AAA1BCAA (1×RJ45+1×RS485, 24 V DI)

Arc‑flash: P3U30-5AAA3BDAA (32DI/16DO, arc module)

Motor version: P3U30-6AAA3BBAC (motor protection profile)

  1. Accessories & Módulos de expansión

All P3 models share a unified accessory system:

Comunicación: RS485 card, fiber modules (P3U10/20)

I/O expansion: DI/DO modules (up to 64DI/32DO)

Special modules: RTD (P3M), arc sensor interface (P3U30/P3F30)

HMI panel for local operation

Anterior:

Deja una respuesta

Dejar un mensaje