Technical Specifications & Application Guide This is a 2‑pole, Tipo C, 25A miniature circuit breaker (MCB) from Schneider Electric’s Acti9 series, with order code A9F18225 and rated breaking capacity 6kA. It provides overload and short‑circuit protection for lighting, socket, and small motor circuits in AC distribution systems. Features include 3‑stage current limiting, quick make mechanism, ...

  • Detalles del producto

Technical Specifications & Application Guide

This is a 2‑pole, Tipo C, 25A disyuntor miniatura (MCB) from Schneider Electric’s Acti9 series, with order code A9F18225 and rated breaking capacity 6kA.

It provides overload and short‑circuit protection for lighting, socket, and small motor circuits in AC distribution systems.

Features include 3‑stage current limiting, quick make mechanism, and protection degree IP40 (front) / IP20 (terminales).

It is compatible with iC65 series accessories for functional expansion.

  1. Desglose del modelo
CódigoSignificadoDescripción
SCHNEIDERMarcaElectricidad Schneider (France), global electrical equipment manufacturer
iC65NSerieActi9 iC65 MCB, N‑type breaking capacity (6el)
2PAGNumber of poles2‑pole, breaks phase and neutral simultaneously, for 230V/400V systems
doCurva de disparoTipo C, instantaneous tripping at 5~10×In (5In~10In)
25ACorriente nominal25 amperes continuous at 30°C ambient
A9F18225Full order codeOfficial unique identifier
  1. Especificaciones principales
ArtículoEspecificaciónNotas
Básico
TipoDisyuntor en miniatura (MCB)Cumple con IEC 60898-1 / ES 10963.1
Tripping typeTermomagnéticoSobrecarga (thermal) + short‑circuit (magnetic) protección
Capacidad de ruptura6elMax breaking current at rated voltage
Rated operational voltageCA 230 V/400 VFor 2‑pole version
Tensión nominal de aislamiento500VMax withstand voltage of insulation
Rated impulse withstand voltage6kVSurge voltage immunity
Frecuencia nominal50/60HzGlobal grid compatible
Características de disparo
Protección contra sobrecarga1.13En (no trip in 1h), 1.45En (trip within 1h)Meets IEC requirements
Short‑circuit protectionInstantaneous at 5In~10InTipo C, suitable for lighting, resistive loads, motores pequeños
Físico & environmental
Dimensiones (Ancho×Alto×Profundidad)18mm×86mm×62mmStandard modular, 2P = 2 módulos (18mm/pole)
Protection degreeIP40 (front), IP20 (terminales)Solid object and moisture protection
Temperatura de funcionamiento-35°C ~ +70°CSuitable for harsh industrial environments
Montaje35carril DIN mmStandard panel mounting
CertificacionesCCC, CE, RoHSMeets Chinese and international safety & environmental standards
  1. Características
  2. Protection performance

3‑stage current limiting: Quickly limits peak current during short circuit, reduces thermal stress, protects equipment and cables.

Selective protection: Coordinates with upstream breakers for selective tripping, limits fault area.

Fault indication: Red window shows tripped status for quick diagnosis.

  1. Structural advantages

Dual‑lock clip: Secures firmly on DIN rail, prevents vibration loosening.

Quick make mechanism: Improves closing speed, reduces arcing, extends life.

Diseño modular: Accepts auxiliary contacts, contactos de alarma, shunt trip, undervoltage trip, etc..

  1. Safety design

Función de aislamiento: Safe isolation distance in OFF position, meets electrical safety rules.

Anti‑misoperation: Handle design prevents accidental closing.

Flame‑retardant housing: V0 grade material improves cabinet safety.

  1. Instalación & Mantenimiento

Installation Rules

  1. Mount vertically (±15°) for proper tripping.
  2. Alambrado: Copper 1.5~35mm², Aluminium 2.5~35mm², torque 1.2~4N·m (depends on cross‑section).
  3. Environment: Avoid damp, polvoriento, corrosive or high‑vibration locations.
  4. Spacing: Maintain clearance for heat dissipation; follow installation manual.

Maintenance Guide

ArtículoIntervalCriterionSolución
Visual inspectionMensualNo damage, no overheating, tight connectionsClean, tighten loose terminals
Function testTrimestralManual ON/OFF smooth, no stickingOperate 3–5 times, check mechanism
Trip testAnnuallySobrecarga & short‑circuit protection functionalTest with dedicated equipment or simulate overload
Accessory checkAnnuallyAuxiliary & alarm contacts workingCheck contact condition, replace damaged parts

Solución de problemas

  1. Tropiezos frecuentes: Check overload → short circuit → high ambient temperature → aging.
  2. Cannot close: Check short circuit → handle position → trip reset → loose wiring.
  3. Overheating: Check terminal torque → overload → ventilation.
  4. Mejora & Reemplazo

5.1 Same‑series Upgrades

iC65H-2P-C25A (A9F28225): H‑type, 10el, for higher short‑circuit current.

iC65L-2P-C25A (A9F38225): L‑type, 15el, for heavy industrial use.

iC65N-2P-C25A‑Vigi (A9V58225): With residual current protection (RCCB), previene descargas eléctricas.

5.2 Functional Accessories

AccesorioTypical ModelFunción
Auxiliary contactA9A269241NO+1NC, remote status indication
Shunt tripA9X16224Remote tripping, p.ej., fire alarm
Undervoltage tripA9X16624Auto‑trip on low voltage
Alarm contactA9A27924Signal when breaker trips

5.3 Cross‑series Alternatives

SerieReemplazoCompatibilidad
fácil9EA9AN 2P C25AMismas dimensiones, 6el, economical
Acti9 CVSCVS100B 2P C25AMCCB, mayor capacidad de rotura (10el), main circuit use
Merlin GerinC65N 2P C25AFully compatible with iC65
  1. Applications
  2. Commercial buildings: Offices, tiendas, hotels – lighting & circuitos de enchufe.
  3. Automatización industrial: Control panels, motores pequeños (≤5.5kW), VFD input protection.
  4. Residential: Home distribution – air conditioners, electrodomésticos de cocina.
  5. Public facilities: Schools, hospitals, stadiums – electrical safety.
  6. Selección & Purchasing Tips
  7. Cargar coincidencia: Type C for lighting, enchufes, motores pequeños (≤5.5kW). Use Type B for pure resistive, Type D for large motors.
  8. Capacidad de ruptura: Choose N (6el), h (10el), l (15el) based on system short‑circuit current.
  9. polacos: 2P for 230V single‑phase where phase + neutral must be disconnected.
  10. Accesorios: Add aux, derivación, undervoltage for smart systems.
  11. Authenticity: Buy from authorized Schneider distributors.
  12. Quick Fault Guide
SymptomPossible CauseSolución
Trips immediately after closingShort circuit / sobrecargaLocate short, reduce load or upsize breaker
Trips after running a whileSobrecarga / temperatura altaReduce load, improve ventilation, check cable size
Handle cannot be pushed to ONNot reset / wiring faultPull to OFF first, then ON; check circuit
Terminal overheatingLoose connectionRetorque after power off, check terminals
No operationThermal‑magnetic unit failedReplace MCB, check coordination

SCHNEIDER iC65N-2P-C25A

Cross‑Brand Replacement Guide

Core Summary: The iC65N-2P-C25A (A9F18225) can be directly replaced by equivalent MCBs from major international and domestic brands.

Key matching requirements:

2PAG, Tipo C, 25A, 6el, 35mm montaje en carril DIN.

  1. International Brand Direct Replacements

TEJIDO

ReemplazoOrder CodeBreakingCompatibilidad
S202-C252CDS252001R02546elBest match, mismas dimensiones, direct swap
S202M-C252CDS262001R025410elHigher breaking capacity
S202L-C252CDS242701R02544.5elEconomy option

siemens

ReemplazoSerieBreakingCompatibilidad
5SL6225-75SL6elReemplazo directo, CEI 60898-1
5SY6225-75SY6elEconomy range
5SN6225-7CN5SN6elClassic, confiable

Eaton

ReemplazoSerieBreakingCompatibilidad
FAZ6-C25/2FAZ6elMismas dimensiones & mounting
PL9-C25/2PL96elHigh performance, fast limiting

Moeller

ReemplazoSerieBreakingCompatibilidad
FAZ6-C25/2FAZ6elMismas dimensiones & mounting
PL9-C25/2PL96elHigh performance, fast limiting
  1. Chinese Domestic Brands
MarcaReemplazoBreakingCompatibilidad
CHINTNXB-63-2P C256elCost‑effective, direct fit
DELIXICDM3-63C25/2P6elMismas dimensiones
LiangxinNDM1-63C25/2P6elHigh quality domestic
TENGENTGM1-63C25/2P6elProtección básica, economical
  1. Critical Parameter Matching
ArtículoOriginal (iC65N-2P-C25A)Must MatchAdjustableNotas
polacos2PAG2PAGDisconnect phase + neutral
CurveTipo C (5~ 10 pulgadas)Tipo CFor lighting & motores pequeños
Current25A25AContinuous rating
Breaking6el≥6kACan be higher (10el)Ensure safe short‑circuit interruption
Montaje35carril DIN mm35carril DIN mmStandard panel mount
Ancho18milímetros18milímetrosH/D may varyFits standard spacing
VoltajeCA 230 V/400 VCA 230 V/400 VUniversal AC system
  1. Notas de reemplazo & Best Practice

Before Replacement

System short‑circuit current ≤ breaking capacity of replacement.

35carril DIN mm, space, terminal size compatible.

Protection coordination with upstream/downstream devices.

Accessory mounting interface compatible.

Replacement has valid certifications (CCC, CE).

Procedure

  1. Power off and verify voltage absence.
  2. Remove wiring and old breaker.
  3. Clip replacement onto DIN rail.
  4. Torque terminals correctly.
  5. Test ON/OFF and tripping.
  6. Update labeling and drawings.

When NOT to replace

Original uses dedicated Schneider accessories (p.ej., Vigi modules).

System short‑circuit current exceeds replacement rating.

Load inrush >10En (unsuitable for Type C).

Extreme environment outside replacement specs.

  1. Recommended Replacement Levels
NivelModelos recomendadosSolicitudAdvantage
1stABB S202-C25Industria, commerceFull performance, global support
Siemens 5SL6225-7
2ndEaton FAZ6-C25/2Control panelsGood value, easy install
Moeller DIL M9-25 C/2
3rdCHINT NXB-63-2P C25Residential, economyBajo costo, fast local supply
DELIXI CDM3-63C25/2P
  1. Common Issues & Soluciones
IssueCauseSolución
Frequent tripping after replacementWrong curve / sobrecargaConfirm Type C, check load, upsize if needed
Will not fitWrong rail / anchoUse 35mm DIN rail, 18mm width model
Wiring difficultIncompatible terminalsUse suitable lugs or select compatible model
Insufficient breaking capacityReemplazo < system short鈥慶ircuit currentUse higher version (p.ej., ABB S202M-C25, 10el)

Cross‑brand replacement for SCHNEIDER iC65N-2P-C25A depends on parameter matching + mechanical compatibility + protection coordination.

Top international brands (TEJIDO, siemens) give identical performance.

Domestic brands (CHINT, DELIXI) offer cost savings.

Always verify specifications and follow electrical safety standards.