chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

 Schneider XCKN2118P20C Limit Switch - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

eléctrico/

Schneider XCKN2118P20C Limit Switch

  In-depth Model Interpretation Model Segment Description XCKN Product family: OsiSense XC standard limit switch, compact Type A, plastic housing 2 Connection type: screw clamp terminals, suitable for 1×0.34mm²~2×1.5mm² wires 1 Contact configuration: 1 Normalmente abierto (NO) + 1 Normalmente cerrado (CAROLINA DEL NORTE), acción rápida 18 Actuator type: thermoplastic roller lever, spring return, side actuation P20 ...

  • Detalles del producto

 

  1. In-depth Model Interpretation
Segmento de modeloDescripción
XCKNProduct family: OsiSense XC standard limit switch, compact Type A, plastic housing
2Connection type: screw clamp terminals, suitable for 1×0.34mm²~2×1.5mm² wires
1Contact configuration: 1 Normalmente abierto (NO) + 1 Normalmente cerrado (CAROLINA DEL NORTE), acción rápida
18Actuator type: thermoplastic roller lever, spring return, side actuation
P20Cable entry: M20×1.5 thread, suitable for cables with outer diameter 7~13mm
doCertification mark: compliant with Chinese CCC certification, suitable for domestic market
  1. Parámetros técnicos básicos

Parámetros eléctricos

Rated operational voltage: AC 240V, DC 125V

Rated operational current: 10A (AC-15: 3A at 240V)

Tipo de contacto: 1NO + 1CAROLINA DEL NORTE, silver alloy contacts

Durabilidad mecánica: 10,000,000 operaciones

Electrical durability: 100,000 operaciones (AC-15)

Minimum actuation torque: 0.1Nuevo Méjico, actuated with low operating force

Mecánico & Parámetros ambientales

Protección de ingreso: IP65 (CEI 60529), dust-tight and water-resistant

Clase de aislamiento: Class II (CEI 61140)

Temperatura de funcionamiento: -25°C ~ +70°C

Storage temperature: -40°C ~ +70°C

Vibration resistance: 25gn (10~500Hz), Cumple con IEC 60068-2-6

Shock resistance: 45gn (11EM), Cumple con IEC 60068-2-27

Montaje: Body mounting, suitable for 24/40mm rails

Dimensiones: 108mm×58mm×36mm (L×W×H)

  1. Características del producto & Ventajas
  2. Structural Benefits

All-plastic housing, lightweight (aprox. 120gramo), excellent corrosion resistance

30° cam actuation design for precise triggering and reduced misoperation

Roller lever can be installed with 360° rotation to adapt to various mounting angles

  1. Performance Assurance

Snap-action contacts (≤10ms) for fast signal response

Double-break contact design for improved breaking reliability

Built-in surge suppression circuit to protect control circuits

  1. Safety Certifications

Multiple certifications including CCC, UL, CSA for global use

Compliant with EN 50047, interchangeable with products to the same standard

  1. Aplicaciones típicas
Campo de aplicaciónSpecific Usage
Líneas de producción automatizadasPosition detection for robotic arms, conveyor positioning, workpiece in-position confirmation
Logistics & warehousingStacker limit protection, rack telescopic positioning, AGV path control
Lifting equipmentElevator/goods lift upper/lower limits, lifting platform travel control, forklift lifting height restriction
Maquinaria de embalajeBag sealer cutting position, labeling machine positioning, cartoner in-position detection
Machine toolsTable travel limitation, tool change position detection, safety door interlock
Construction machineryCrane limit protection, concrete mixer level control, elevator door safety detection
  1. Instalación & Wiring Guide

Pasos de instalación

  1. Select a flat and rigid mounting surface with sufficient operating space (≥50mm)
  2. Secure with M4 bolts (torque 2.5Nm) or mount on 24/40mm standard rails
  3. Adjust roller orientation to ensure proper contact with actuating parts (recommended contact angle 30°)
  4. Install M20 cable gland to maintain IP65 protection

Especificaciones de cableado

Incoming wire: 1×0.34mm²~2×1.5mm² stranded or solid wire

Terminal torque: 0.8Nuevo Méjico, avoid over-tightening to prevent damage

Separate high-voltage (>24V) and low-voltage (<24V) control circuits to reduce interference

For long-distance wiring (>10metro), shielded cable with single-end grounding is recommended

  1. lternative Models & Compatibility Solutions

Alternatives within Schneider Series

XCKN2118P12C: M12×1.5 cable entry, suitable for 4~8mm cables

XCKN2118G11C: PG11 cable entry, suitable for 6~12mm cables

XCKN2118P20: International version (without C mark), for export projects

Cross-brand Alternatives

MarcaAlternative ModelCompatibilidad
OmronD4C-1320★★★★☆ (Same electrical parameters, slight differences in mounting dimensions)
siemens3SE5 232-0CH01★★★★☆ (IP65 protection, identical contact configuration)
TEJIDOLS35M-11★★★★☆ (Same actuator type, matching actuation torque)
  1. Selección & Purchasing Guidelines
  2. Three Key Selection Factors

Actuation type: confirm side or front actuation to select the corresponding actuator

Cable specification: choose M20/M12/PG11 entry based on on-site cable outer diameter

circuito de control: select rated voltage model for AC/DC systems accordingly

  1. Purchasing Tips

Look for original Schneider packaging; XCKN series has unique anti-counterfeit codes verifiable on the official website

Avoid bulk or loose-pack products; items without CCC certification are prohibited for domestic use

Require suppliers to provide product certificates and type test reports

  1. Warranty & Servicio postventa

Standard warranty period: 18 meses

Fault response: technical support from authorized Schneider service providers within 48 horas

Repair & replacement: free replacement for non-artificial damage

  1. Solución de problemas
SymptomPossible CauseSolución
Contacts do not actuateInsufficient actuation forceAdjust mounting position to ensure actuation torque ≥0.1Nm
Contacts welded closedOvercurrent operationCheck control circuit current to ensure it is within rated value
Loss of protectionLoose cable glandRetighten M20 connector and replace damaged sealing ring
Signal fluctuationPoor wiring connectionCheck terminal torque and re-crimp wires

Selection Recommendation:

XCKN2118P20C is a highly versatile standard limit switch, especially suitable for position detection and safety protection in automation equipment, logistics systems and construction machinery. For special environmental applications, stainless steel housing (XCKJ series) or high-temperature resistant type (XCKT series) puede ser considerado.

Anterior:

Próximo:

Deja una respuesta