Siemens 3RV1901-1A Side-Mounted Auxiliary Contact

Nombre completo del producto: SIRIUS Classic side-mounted auxiliary contact (lateral auxiliary switch) Suitable for legacy 3RV1 motor protection circuit breakers, frame sizes S00 / S0 / T2 / T3; terminal de tornillo, 1NO+1NC (1 normalmente abierto + 1 normalmente cerrado) Ciclo vital: Obsoleto (Phase-out). It is an accessory for the older 3RV1 platform; the manufacturer promotes the upgraded ...

  • Detalles del producto

Nombre completo del producto: SIRIUS Classic side-mounted auxiliar contacto (lateral auxiliary switch)

Suitable for legacy 3RV1 motor protection circuit breakers, frame sizes S00 / S0 / T2 / T3; terminal de tornillo, 1NO+1NC (1 normalmente abierto + 1 normalmente cerrado)

Ciclo vital: Obsoleto (Phase-out). It is an accessory for the older 3RV1 platform; the manufacturer promotes the upgraded 3RV2 platform.

Especificaciones clave

Configuración de contacto: 1NO + 1CAROLINA DEL NORTE

Montaje: Lateral side mounting (distinguished from front-mounted 3RV1901-1E)

Alambrado: Screw-clamp terminals

Calificación de contacto: AC-12, máximo. 6A / 240V y; commonly used for 24VAC/DC, 220VAC signal feedback in control circuits

Protección: IP20

Solicitud: Passive feedback of circuit breaker ON/OFF status for PLC, indicator lamps and circuit interlocks

Compatible breaker bodies: 3RV10, 3RV11, 3RV13, 3RV14, 3RV16 and other legacy 3RV1 motor protectors; not directly compatible with the new 3RV2 series

Explicación del código del modelo

3RV1: Legacy SIRIUS motor protection circuit breaker series

3RV19: Accessory group for the 3RV1 series

01: interruptor auxiliar

1A: Lateral mounting, 1NO+1NC, terminales de tornillo

Opciones de reemplazo (Importante)

  1. If migrating to 3RV2 circuit breakers: Front auxiliary contact 3RV2901-1E (1NO+1NC, tornillo); lateral type 3RV2901-2E (2NO+2NC)
  2. If keeping the existing 3RV1 breaker body: Sólo stock / second-hand 3RV1901-1A is available; 3RV29xx accessories cannot be fitted onto legacy 3RV1 breakers
  3. Other accessories of the same series for reference:

3RV1901-1E: Contacto auxiliar montado en el frente, 1NO+1NC

3RV1901-1J: Lateral, 2NO

3RV1901-1C: Lateral, 2CAROLINA DEL NORTE

Full Accessory List for siemens 3RV1 (Legacy SIRIUS Motor Protection CB)

Compatible bodies: 3RV10 / 3RV11 / 3RV13 / 3RV14 / 3RV16; frame S00, S0, T2, T3; entire series obsolete. Accessories fit only 3RV1 bodies and cannot be installed on 3RV2

Terminal distinction: -1xxx = screw terminals; -2xxx = spring-cage terminals

  1. Contactos auxiliares (Status feedback, reflects CB ON/OFF position)
Número de pedido.Posición de montajeConfiguración de contactoObservaciones
3RV1901-1ALateral1NO+1NCModelo consultado, terminal de tornillo
3RV1901-1BLateral2NO+2NCTornillo
3RV1901-1CLateral2CAROLINA DEL NORTETornillo
3RV1901-1JLateral2NOTornillo
3RV1901-2ALateral1NO+1NCjaula de resorte
3RV1901-2BLateral2NO+2NCjaula de resorte
3RV1901-2CLateral2CAROLINA DEL NORTEjaula de resorte
3RV1901-1EFrente (transverso)1NO+1NCTornillo, most common front type
3RV1901-1FFrente2NOTornillo
3RV1901-1DFrente2CAROLINA DEL NORTETornillo
3RV1901-1GFrente1NO+1NCFor low-current / electronic circuits, dust-resistant
3RV1901-0HDust cover for front auxiliary contact—Protective cap, pack of 10

Limitación: Maximum one lateral auxiliary contact per 3RV1 breaker; montado en el frente + lateral can be used together.

  1. Fault Signal Switch (Trip signal, distinguishes overload / cortocircuito, not equal to standard auxiliary contact)
Número de pedido.Configuración de contactoObservaciones
3RV1921-1M1NO+1NCFault contact, actuates only on overload or short-circuit trip; no action during manual ON/OFF. For PLC fault alarm.
  1. Liberación de subtensión (UVT, trip on loss of supply)
Número de pedido.Voltaje de la bobina
3RV1902-1AB0AC24V 50Hz
3RV1902-1AF0AC110V 50Hz
3RV1902-1AP0AC230V 50Hz
3RV1902-1DC0CC 24 V
  1. Liberación de derivación (SHT, remote tripping)
Número de pedido.Voltaje de la bobina
3RV1903-1AB0CA 24V
3RV1903-1AF0CA 110 V.
3RV1903-1AP0CA 230 V.
3RV1903-1DC0CC 24 V

Release rule: Undervoltage release and shunt release are mutually exclusive, cannot be fitted on the same breaker.

  1. Door-coupled Rotary Operating Mechanism (External cabinet operation, IP65, padlockable)
Número de pedido.Longitud del ejeCompatible Frame
3RV1926-0B130milímetrosS0 / T2 / T3
3RV1926-0K330milímetrosS0 / T2 / T3

Función: Cabinet door cannot be opened when CB is closed; lockable in OFF position to prevent accidental closing.

  1. Busbar Modules (Main circuit interconnection for side-by-side mounting)

S00 / Marco S0

Número de pedido.Objetivo
3RV1915-1ABBusbar for 2 breakers
3RV1915-1BBBusbar for 3 breakers
3RV1915-1CBBusbar for 4 breakers
3RV1915-1DBBusbar for 5 breakers
3RV1915-3AB2 breakers (with space for accessories)
3RV1915-3BB3 breakers (with space for accessories)
3RV1915-3CB4 breakers (with space for accessories)

S2 Frame

Número de pedido.Objetivo
3RV1935-1A2 breakers
3RV1935-1B3 breakers
3RV1935-1C4 breakers
3RV1935-3A2 breakers (with space for accessories)
  1. Contactor Link Module (Direct assembly for 3RV1+3RT1 starter group, no extra busbar)
Número de pedido.Compatible Assembly
3RA1941-1BMecánico & electrical link for 3RV1.41 + 3RT1.4 starter combination
  1. Sellos, Cubiertas & Other Mechanical Accessories
Número de pedido.Descripción
3RV1920-1Akit de sellado, prevents unauthorised adjustment of current setting dial
3RV1910-1AExtended terminal cover

Cross Reference for Migration to 3RV2 Platform

Legacy 3RV1 Part No.3RV2 Replacement
3RV1901-1A (Lateral 1NO+1NC, tornillo)3RV2901-1A
3RV1901-1E (Front 1NO+1NC, tornillo)3RV2901-1E
3RV1921-1M (Fault signal switch)3RV2921-1M

Notas de selección clave

  1. Contactos auxiliares estándar (3RV1901): Only indicate handle position, cannot distinguish fault trip. Fault alarm requires 3RV1921-1M.
  2. Liberación de subtensión: The breaker must be closed before supply is restored; it trips automatically when supply fails. liberación de derivación: Trips when energised.
  3. Busbars have two versions: standard and accessory-space type. If auxiliary contacts are fitted on the side, select suffix 3AB/3BB/3CB.
  4. Only stock items are available for purchase; manufacturer no longer accepts new production orders.

Operating Principle of 3RV1901-1A (Mechanically Synchronised Position Auxiliary Switch)

Core summary: Pure mechanical linkage, contact state follows the mechanical position of the 3RV1 handle synchronously. It only reflects ON / OFF status and cannot detect overload or short-circuit faults.

It is a passive snap-on auxiliary contact module clipped to the side of the 3RV1 motor protection circuit breaker. No electromagnetic components or trip detection mechanism inside.

  1. Mechanical Linkage Structure

The operating mechanism of the breaker handle and main contacts has a drive cam. Once 3RV1901-1A is fully engaged, its internal lever bears against this cam:

Handle movement → cam displacement → actuates internal rocker mechanism of auxiliary contact

Internal double-break silver bridge contact, one changeover contact (CO:1NO+1NC) with snap-action spring to ensure clean switching without chatter.

Operating States

  1. Circuit Breaker ON

Handle switched to ON position, cam fully advanced: NO cerrado, NC abierto

→ ON signal to PLC, run indicator lamp energised

  1. Circuit Breaker OFF (Manual opening)

Handle switched to OFF position, cam retracts: NO abierto, NC cerrado

→ Stop status feedback

  1. Circuit Breaker Tripped by Overload / Cortocircuito

⚠️ Importante: después de tropezar, the handle rests in the intermediate trip position. The handle mechanism also drives the cam, so 3RV1901-1A switches to OFF state (NO abierto, NC cerrado).

✅ Limitation: This contact alone cannot tell whether opening is manual or fault-induced.

👉 Separate fault alarm requires 3RV1921-1M (fault signal switch). It has an independent trip plunger and only switches state on overload/short-circuit trip; no action on manual ON/OFF.

  1. Características eléctricas

Passive dry contact, no internal power supply; it is simply a mechanical switch to route low-current signals for PLC digital inputs, lamps and interlock circuits.

Utilisation category AC-12: 6A / 240V y. Designed exclusively for control signal circuits, not permitted for main power circuits.

Contact timing: Switches nearly synchronously with the main breaker contacts, no advance or delayed action (slightly different from contactor auxiliary contacts).

  1. Comparison with 3RV1921-1M (Common Pitfall in Selection)
Número de pieza.Actuation SourceDistinguish manual OFF vs fault tripSolicitud
3RV1901-1ACam from handle mechanism❌No, same contact state for both casesComentarios de posición, run indication, general interlock
3RV1921-1MIndependent plunger from thermal / magnetic trip unit✅ Sí, state changes only on fault tripalarma de fallo, registro de fallas, fault interlock shutdown
  1. Installation Constraints & Notas adicionales

Lateral mounting. Maximum one lateral auxiliary contact (3RV1901-1A) per 3RV1 breaker; one front auxiliary contact (3RV1901-1E) may be added together.

Poor snap fit causes the internal lever to lose engagement with the cam: handle moves but auxiliary contact does not toggle (most frequent site fault).

Insulated housing separates high-voltage main circuit from signal contacts, meeting low-voltage isolation requirements.

Common Site Misconception

❌ Malentendido: 3RV1901-1A is a fault contact and triggers alarm when tripped

✅ Corrección: It is only a position contact. An open signal from this contact to PLC merely means the breaker is not closed. Combine it with 3RV1921-1M using AND/OR logic to discriminate fault trip.