Telemecanique XS618B1MAL2 Inductive Proximity Sensor

M18 Flush-mount Inductive Proximity Switch (2-wire AC/DC universal, Normalmente abierto NO) Model Code Explanation XS6: General-purpose inductive proximity sensor of XS6 series 18: M18 threaded cylinder B: Standard sensing distance 1: Normalmente abierto (NO) METRO: 2-wire AC/DC universal A: Cable outlet L2: 2-meter fixed cable Core Electrical & Mechanical Specifications Item Parameter Nominal Sensing Distance ...

  • Detalles del producto

M18 Flush-mount Inductive Proximity Switch (2-wire AC/DC universal, Normalmente abierto NO)

  1. Explicación del código del modelo

XS6: Propósito general sensor de proximidad inductivo of XS6 series

18: M18 threaded cylinder

B: Standard sensing distance

1: Normalmente abierto (NO)

METRO: 2-wire AC/DC universal

A: Salida de cables

L2: 2-meter fixed cable

  1. Núcleo Eléctrico & Especificaciones mecánicas
ArtículoParámetro
Distancia de detección nominal Sn8 milímetros, montaje empotrado (tipo blindado)
Voltaje de suministro24…240 V AC/DC (50/60Hz)
Tipo de salida2-cable, Normalmente abierto (NO)
Corriente de cargacorriente continua: 5~200mA; C.A.: 5~300mA
Body Length62 milímetros; Thread M18×1
Material de la carcasaLatón niquelado; Sensing face PPS
Cable2m cable fijo
Clase de protecciónIP68 / IP69K, double insulation
Temperatura de funcionamiento-25℃ ~ +70℃
Frecuencia de conmutación1kilociclos
Detected ObjectMetallic conductors (optimal for ferromagnetic metals)
  1. Pautas de instalación
  2. Montaje empotrado (Shielded Type): The sensor can be fully embedded inside a metal mounting seat without false triggering caused by side metal.
  3. Mounting hole M18, supplied with double lock nuts.
  4. Minimum spacing between adjacent sensors of the same model ≥3×Sn (≥24mm) para evitar interferencias mutuas.
  5. Target metal plate thickness ≥1mm, area ≥30×30mm for stable detection.
  6. Instrucciones de cableado

2-diseño de alambre, no polarizado (CA/CC universales):

Connect two wires in series between power supply and load.

When metal approaches the sensing face → switch turns ON (NO contact closed).

Nota: 2-wire sensors carry standby leakage current. False actuation may occur with low-power loads (high-resistance relay coils). Load calculation is required during selection.

  1. Escenarios de aplicación típicos

Metal detection on conveyor lines, machine tool limit positioning, detección de presencia de material, hydraulic/cylinder position feedback, food processing washdown equipment (IP69K for high-pressure cleaning), maquinaria de embalaje.

  1. Alternativa / Equivalent Models within the Series

XS618B1MBL2: 2-wire Normally Closed NC, otros parámetros idénticos

XS618B1PAM12: 3-wire PNP Normally Open, M12 connector type

XS618B1NAM12: 3-cable NPN normalmente abierto, M12 connector type

  1. Solución de problemas comunes
  2. Sin salida: Verify supply voltage within 24~240V; confirm metal target enters the 8mm sensing range; inspect cable for breakage.
  3. falso disparo: For flush mounting, ensure mounting metal does not cling to the sensing face; check interference from neighboring sensors.
  4. Cannot turn off: Too small load; leakage current of 2-wire sensor keeps relay energized. Replace with 3-wire PNP/NPN version.

Operating Principle of Flush-mount Inductive Proximity Switches (such as XS618B1MAL2)

Principio básico

Inductive proximity switches work based on the eddy current effect, with a high-frequency oscillating coil as the core component.

  1. Internal circuit generates a high-frequency alternating magnetic field, radiating outward from the front sensing face.
  2. When a metal target approaches the sensing face, the alternating magnetic field induces eddy currents on the metal surface.
  3. Eddy currents generate a reverse magnetic field to counteract the original oscillating magnetic field of the sensor.
  4. The amplitude of the oscillation circuit attenuates; detection circuit identifies this change and outputs switching signal (ENCENDIDO/APAGADO).

✅ Core difference between Flush-mount (Blindado) and Non-flush (Sin blindaje): A metal shielding ring surrounds the coil

Structural Features of Flush-mount (Shielded Type)

A metal shielding layer wraps the sides of the sensing coil for flush-mount sensors:

Restricts magnetic field to directly in front of the sensor, nearly no magnetic field on lateral sides.

Por lo tanto, it can be fully screwed into metal mounting brackets with sensor end face flush to mounting surface and no false triggering from surrounding metal.

Trade-off: Under identical specifications, sensing distance is shorter than non-flush type (Sn=8mm for XS618B1MAL2 flush model).

Tipo sin descarga: Magnetic field exists on sides; cannot be embedded in metal seat, otherwise continuous triggering occurs, with longer sensing distance.

Signal Output Flow (2-wire NO model XS618B1MAL2)

  1. Power on → internal oscillator starts oscillation.
  2. No metal nearby → stable oscillation, switch open (NO normalmente abierto).
  3. Metal approaches and reaches rated sensing distance Sn → oscillation attenuates, detection circuit actuates and the 2-wire circuit conducts.
  4. Metal moves away → oscillation recovers, switch opens.

Características clave

  1. Only detects metal: Plástico, wood and glass cannot produce eddy currents and will not be detected. Metales ferromagnéticos (acero, hierro) deliver optimal sensing distance; effective distance attenuates for non-ferrous metals such as copper and aluminum.
  2. Velocidad de respuesta rápida, suitable for high-speed counting and position detection.
  3. Flush mounting resists side metal interference, preferred for machine tools, conveyor metal frame installations.
  4. 2-wire version carries leakage current; load selection needs attention.

Simple Comparison Table

TipoEstructuraCaracterística de montajeDistancia de detección
Montaje empotrado (Blindado)Coil with metal shielding ringCan be flush embedded into metal holesShorter
Sin descarga (Sin blindaje)No side shieldingCannot embed into metal; front clearance requiredLonger

Common Application Scenarios of Inductive Proximity Switches

Características principales: Detect metal only, non-contact, sin desgaste mecánico, resistant to dust and oil; Flush type (XS618B1MAL2) suitable for flush installation on metal frames

  1. Detección de posición / Límite de viaje (Más común)
  2. Información de posición del cilindro: Detect extended/retracted end position of cylinder piston rod to confirm completion of cylinder action, standard fitting for pneumatic automation; M18 flush sensors widely used on cylinder mounting seats.
  3. Machine tool travel limit: Soft limit and hard overtravel protection for CNC machine slides and worktables; turret and tool magazine positioning, tool change confirmation; fixture clamping verification to judge workpiece seating status.
  4. Válvula, baffle and safety door status detection: Detect closure of metal safety gates for safety interlock; equipment startup prohibited when door open.
  5. Robot positioning: Homing and station in-place detection for robotic arms.
  6. Cálculo, Speed Measurement & Rotational Speed Monitoring
  7. Metal workpiece counting on conveyor lines: Count metal parts, tornillos, metal caps and metal pallets on production lines for output statistics.
  8. velocidad de rotación / line speed acquisition: Gear tooth disc fitted on motor shaft; proximity sensor detects gear teeth pulses, PLC collects pulses to calculate rotation speed and line speed, widely used for conveyors and reducer spindle monitoring.
  9. Material break / shortage detection: Monitor feeding of metal rods to confirm material delivery and breakage.
  10. Transmitir & Clasificación logística
  11. Detect arrival of metal workpieces on belt conveyors to trigger cylinder actions for transfer and sorting;
  12. Metal pallet presence detection and rack positioning in automated warehouses;
  13. Jam monitoring: Alarm for material accumulation and blockage.
  14. Embalaje & Maquinaria alimentaria (Suitable for XS618B1MAL2 with IP68/IP69K)

Detection of cans, metal caps and aluminum foil seals to verify cap presence;

Trigger filling when metal containers arrive at filling stations;

High-pressure washdown capability; flush sensors preferred for food & beverage cleaning lines.

  1. Fabricación de automóviles

Workpiece positioning at welding stations and fixture clamping confirmation for welded car bodies;

Gear position detection for gearboxes and presence check of wheel hubs;

Stable performance under welding slag and heavy dust; inductive sensors outperform photoelectric sensors in contaminated environments.

  1. Hidráulico & Maquinaria de construcción

Hydraulic cylinder position detection and metal float liquid level monitoring;

Position feedback for machinery doors and buckets;

Adapt to heavy vibration and oily harsh environments.

  1. Other Segmented Applications
  2. Stamping equipment: Mold closure detection and safety interlock;
  3. Equipos electronicos: Metal component detection on SMT lines;
  4. Bomba & admirador: Shaft stall monitoring via gear tooth speed measurement.

Consejos de selección (For XS618B1MAL2)

✅ Flush-mount (Shielded Type): Can be installed flush within metal mounting seats, free from false triggering by surrounding metal; preferred for machine frames and cylinder mounts.

⚠️ Limitación: Only identifies metal, plástico, paper and non-metallic workpieces cannot be detected; effective sensing distance shortens for copper and aluminum.

⚠️ 2-wire models (p.ej. XS618B1MAL2) have leakage current, which may cause false pull-in of small-load relays.

telemecanica XS618B1 Series Full Model List (M18 Flush Mount, Sn=8mm)

Unified Base Specification: XS618B1 = XS6 series, M18 threaded, flush shielded type, nominal sensing distance 8mm, carcasa de latón niquelado, IP68/IP69K, -25~+70℃

Regla de codificación del modelo: XS618B1 + Código de salida + Tipo de salida + Length/Connector

M = 2-wire AC/DC; P=PNP; N=NPN

A=Normally Open NO; B=Normally Closed NC

L2=2m cable; L5=5m cable; M12=M12 circular connector; AU20=1/2″UNF connector

  1. 2-wire AC/DC (Branch of XS618B1MAL2, 24~240 V CA/CC)
ModeloProducciónAlambradoSalidaObservaciones
XS618B1MAL2NO2-cable2cable mModelo de referencia, Body L=62mm
XS618B1MBL2CAROLINA DEL NORTE2-cable2cable mSame specs as MAL2
XS618B1MAU20NO2-cable1/2″UNF connectorAmerican thread connector, L=73mm
XS618B1MBU20CAROLINA DEL NORTE2-cable1/2″UNF connectorNormally closed version with American connector
  1. 3-wire DC PNP (12~48VDC, most common for PLC)
ModeloProducciónAlambradoSalidaObservaciones
XS618B1PAL2NO3-wire PNP2cable mL=62mm
XS618B1PBL2CAROLINA DEL NORTE3-wire PNP2cable mL=62mm
XS618B1PAL5NO3-wire PNP5cable mLong cable version
XS618B1PBL5CAROLINA DEL NORTE3-wire PNP5cable mLong cable normally closed
XS618B1PAM12NO3-wire PNPConector M12 de 4 pinesL=74mm
XS618B1PBM12CAROLINA DEL NORTE3-wire PNPConector M12 de 4 pinesL=74mm
  1. 3-wire DC NPN (12~48VDC, for NPN-type PLC)
ModeloProducciónAlambradoSalidaObservaciones
XS618B1NAL2NO3-wire NPN2cable m62mm body
XS618B1NBL2CAROLINA DEL NORTE3-wire NPN2cable m62mm body
XS618B1NAM12NO3-wire NPNconector M1274mm body
XS618B1NBM12CAROLINA DEL NORTE3-wire NPNconector M1274mm body
  1. ATEX Dust Explosion-proof Versions (Explosive Atmosphere)
ModeloProducciónAlambradoSalidaObservaciones
XS618B1PAL10EXNOPNP10cable mATEX dust hazardous area
XS618B1PBL10EXCAROLINA DEL NORTEPNP10cable mATEX dust hazardous area

Guía de selección rápida

  1. 2-wire models starting with M (XS618B1MAL2): Universal AC/DC, no polarity distinction; ⚠️ leakage current exists, prone to false relay pull-in for tiny loads, adecuado para cargas pesadas.
  2. 3-wire P/N prefix: DC12~48V, PNP/NPN, protección contra cortocircuitos, standard PLC selection, preferred replacement for 2-wire sensors.
  3. Suffix L2/L5: Fixed cable; M12/AU20: Detachable connector for easier maintenance.
  4. A=NO Normally Open, B=NC Normally Closed: Cuando el metal se acerca, NO closes and NC opens.

Extended M18 Flush Models in the Same Series (Longer Sn, Non-B1)

XS618B4PAL2: Montaje empotrado, Sn12mm, PNPNO, 2cable m