Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

CHINT CJX2-3210 AC Contactor - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

contacteur/

CHINT CJX2-3210 AC Contactor

CJX2-3210 is a 3-pole 32A AC contactor from CHINT CJX2 series, avec 3 NO main poles + 1 NO auxiliary contact. It is suitable for controlling 15kW motors at AC-3 380V. Coil voltages include 220V/380V and others. Direct replacement models include Schneider LC1N3210, Siemens 3RT6035-1AN20, etc.. Model Explanation & Basic Positioning Model Part Meaning CJX2 ...

  • Détails du produit

CJX2-3210 is a 3-pole 32A Contacteur CA from CHINT CJX2 series, avec 3 NO main poles + 1 NO auxiliary contact.

It is suitable for controlling 15kW motors at AC-3 380V. Coil voltages include 220V/380V and others.

Direct replacement models include Schneider LC1N3210, Siemens 3RT6035-1AN20, etc..

  1. Model Explanation & Basic Positioning
Model PartSignification
CJX2CHINT AC contactor series (equivalent to Schneider LC1‑D series)
32Rated operational current 32A (AC‑3 utilization category at 400V)
10Contacts auxiliaires: 1 NON + 0 Caroline du Nord

Positionnement du produit:

Industrial‑grade general‑purpose AC contactor, suitable for frequent starting and control of AC motors.

Can form a magnetic starter with thermal overload relays for motor protection.

  1. Paramètres techniques clés
ArticleSpécification
Rated operational voltageUp to 690V AC (50/60Hz)
Rated operational current32UN (AC‑3 400V), thermal current Ith = 50A
Controlled power15kW (AC‑3 380V), 21UN (AC‑3 660V)
Contact auxiliaire1 NON, rated 5A/220V AC
Coil voltageFacultatif: 220V/380V/110V/36V/24V AC
Insulation characteristicsUI = 660V, compliant with GB14048.4 / IEC60947‑4‑1
Mécanique / electrical life10 million times / 1 million times (AC‑3)
Dimensions (L×L×H)83×58×101 mm
MontageRail DIN standard de 35 mm
  1. Caractéristiques structurelles & Matériels
  2. Contacts en alliage d'argent: Excellent conductivity and arc resistance, ensuring reliable switching.
  3. 32‑sheet silicon steel core: Reduces hysteresis loss, smoother pull‑in, stable operation.
  4. Flame‑retardant housing: Meets V0 flame rating, improves safety.
  5. Clear side marking: Modèle, tension, Certification CCC, etc..
  6. Applications
  7. Automatisation industrielle: Contrôle du moteur, les fans, pompes, compresseurs.
  8. Building electrical: CVC, fire pumps, exhaust fans.
  9. Agricultural machinery: Irrigation, feed processing equipment.
  10. Power systems: Remote circuit control in distribution panels.
  11. Typical matching: Long‑running oil station motors, unidirectional equipment (no NC auxiliary required).
  12. Comparison Within CJX2 Series
ModèleCourant nominalAux. ContactsAC‑3 380V PowerDimensions (mm)
CJX2‑09109UN1 NON4kW73×47×82
CJX2‑181018UN1 NON7.5kW73×47×82
CJX2‑251025UN1 NON11kW83×58×96
CJX2‑321032UN1 NON15kW83×58×101
CJX2‑401140UN1 NON + 1 Caroline du Nord18.5kW128×79×116
CJX2‑651165UN1 NON + 1 Caroline du Nord30kW128×79×116
  1. Cross‑Brand Replacements
MarqueModèle de remplacementCompatibilité
SchneiderLC1N3210M7N / LC1R3210M5NMêmes dimensions & parameters
Siemens3RT6035‑1AN20 (domestic type)Functionally equivalent, mounting compatible
ABBA145‑30‑11 (32A class)Aux. can be configured as 1 NON
DélicieuxCJX2‑3210Fully interchangeable
Commutateur ChangshuCK3‑3210Same performance & parameters
  1. Sélection & Application Notes
  2. Coil voltage: Selected per control circuit (commonly 220V / 380V).
  3. Correspondance de charge: 32A ≈ 15kW at AC‑3 380V; avoid overload.
  4. Aux. contact expansion: F4‑11 or similar modules can be added.
  5. Protection coordination: Used with NR2 series thermal relays (par exemple. NR2‑36) for overload protection.
  6. Environnement: Operating temperature ‑5°C ~ +40°C; avoid dust & corrosive gas.

Packing: 4 pièces/boîte, 32 pcs/carton

Comparison of CHINT Contactor Series

Aperçu:

CHINT contactors are divided into:

Classic (CJX2/CJ20/CJX8), Mise à niveau (NXC/NC5), High‑Power (NC8), DC Special (CJZ8/NCZ5).

NXC fully replaces CJX2 with better performance; NC5 focuses on intelligence & modularity; NC8 covers ultra‑high current; CJZ8 is for DC control.

Priority: NXC / NC5; use special series for special applications.

  1. Series Positioning & Remplacement
SériePositioningReplaced By / ReplacesPrincipales fonctionnalités
CJX2Classic generalFully replaced by NXCCost‑effective, simple structure, flexible aux. contacts
NXCNew generationReplaces CJX2, upgradedHigh efficiency, long life, standard 1NO+1NC, strong modularity
NC5Smart & premiumMarché haut de gammeWide temp ‑25°C~+55°C, communication, complex automation
NC8High‑power heavy‑dutyIndependent, up to 1000AUp to 1000A AC‑3 415V, for large motors & heavy industry
CJX8Traditional heavy‑dutyPartially replaced by NC8Direct‑operated double break, suitable for legacy retrofits
CJ20Traditional generalReplaced by NXC/NC5Mature structure, low cost, civil & light industry
NXC‑XMGSpecial loadIndependentFor fans & pompes, high energy saving
CJZ8/NCZ5DC dedicatedIndependentEnhanced arc extinguishing, new energy & energy storage
  1. Paramètres techniques clés

2.1 Basic Electrical Data

SérieCurrent RangeTension nominaleAC‑3 380V PowerStandard Aux. Contacts
CJX29A~95AUp to 690V0.75kW~45kWBelow 32A: 1NO/1NC; ≥40A:1NON+1NC
NXC6A~630AUp to 690V0.37kW~315kWFull range: 1NON+1NC
NC56A~630AUp to 690V0.37kW~315kW1NON+1NC, expandable to 6NO+6NC
NC86A~1000AUp to 690V0.37kW~500 kW2NON+2NC, expandable to 6NO+6NC
CJX89A~250AUp to 660V4kW~110kW3NO+1NO/1NC or 4NO
CJ2010A~630AUp to 660V5.5kW~315kW1NON+1NC

2.2 Life & Environnement

SérieDurée de vie mécaniqueDurée de vie électrique (AC‑3)Operating TempMontage
CJX210 million1 million‑5°C~+40°C35mm DIN / screw
NXC12 million1.2 million‑25°C~+55°C35mm DIN / screw
NC515 million1.5 million‑25°C~+55°C35mm DIN / screw
NC810 million0.8 million (high current)‑25°C~+55°CMainly screw
CJ208 million0.8 million‑5°C~+40°CScrew
  1. Structure & Functional Differences

3.1 CJX2 (Classic)

Structure: Direct‑operated single break, modular; F4 aux., F5 timer, NCF1 side aux. available.

Contacts: Alliage d'argent, 3P main, flexible aux. (10/01/11).

Coil: CA/CC, 24V~380V.

3.2 NXC (Mise à niveau)

Optimized magnetic system, coil power ≈ 30% lower than CJX2.

Improved silver alloy contacts, better arc extinguishing.

Standard 1NO+1NC; supports aux., timer, mechanical interlock.

3.3 NC5 (Smart Premium)

Optional communication module (Modbus, etc.) for IIoT.

Wide temperature, suitable for outdoor & harsh environments.

Enhanced insulation & short‑circuit withstand.

3.4 NC8 (High‑Power)

Enhanced arc chamber for high‑current breaking up to 1000A.

Optimized heat dissipation for heavy‑duty continuous operation.

Heavy‑duty mechanical structure, high vibration resistance.

3.5 CJX8 (Traditional Heavy‑Duty)

Direct‑operated double break; front‑connected or rear‑connected versions.

Jusqu'à 4 poteaux (3 principal + 1 aux or 4 principal) for special applications.

3.6 DC Contactors

CJZ8: Low‑voltage DC (12V~220V), up to 40A, small DC loads.

NCZ5: High‑voltage DC (up to 1500V), up to 500A, new energy vehicles & energy storage.

Dedicated DC arc extinguishing structure.

  1. Scénarios d'application
SérieBest ForTypical LoadNot Recommended
CJX2Legacy retrofit, budget projectsSmall motors ≤15kW, éclairage, chauffageHigh‑end automation, harsh environments
NXCAutomatisation industrielle, new projectsMedium motors ≤315kW, les fans, pompesUltra‑large motors, special DC loads
NC5Smart factories, complex systems, de plein airMoyen & large motors, production linesCost‑sensitive simple circuits
NC8Large industry, pouvoir, metallurgyLarge motors ≤500kW, transformateursSmall loads, civil buildings
CJX8Legacy maintenance, special controlTraditional machinery, special circuitsNew smart projects
CJ20Civil, light industry, temporary powerAC units, pompes, small machinesFrequent switching, high‑end automation
DC seriesNew energy, energy storage, railDC motors, batteries, chargeursAC loads
  1. Guide de sélection & Replacements

5.1 Selection Priority

  1. New projects: NXC (replaces CJX2)
  2. Smart/complex systems: NC5
  3. Ultra‑high power >315kW: NC8
  4. DC loads: CJZ8 / NCZ5
  5. Legacy retrofit: CJX2/CJ20/CJX8 or upgrade to NXC/NC5

5.2 Cross‑Series Replacement

OriginalRecommended ReplacementAdvantage
CJX2‑09~95NXC‑06~100Standard 1NO+1NC, life +20%, power ‑30%
CJ20‑10~630NXC‑12~630 / NC8‑12~1000Better performance, modular, easier maintenance
CJX8‑09~250NC8‑06~250Better arc extinguishing, wide temperature

5.3 Model Selection Tips

Current: 32A ≈ 15kW; 63A ≈ 30kW; 100A ≈ 45kW at AC‑3 380V.

Aux. contacts: NXC has 1NO+1NC standard; CJX2 uses 10/01/11.

Coil: 220V/380V/110V/36V/24V AC/DC.

Montage: 35mm DIN preferred; screw for high power.

  1. Special Notes: CHINT CJX2‑3210

As a representative model of CJX2 series, CJX2‑3210 is a 3‑pole 32A AC contactor with 3 NO main contacts + 1 NO auxiliary contact, suitable for 15kW motor control at AC‑3 380V.

Common replacements:

CHINT NXC‑3210 (upgraded)

Schneider LC1N3210M7N

Siemens 3RT6035‑1AN20

ABB A145‑30‑11 (32A class)

Précédent: