CJX2-3210 is a 3-pole 32A Contacteur CA from CHINT CJX2 series, avec 3 NO main poles + 1 PAS de contact auxiliaire.
It is suitable for controlling 15kW motors at AC-3 380V. Coil voltages include 220V/380V and others.
Direct replacement models include Schneider LC1N3210, Siemens 3RT6035-1AN20, etc..
- Explication du modèle & Basic Positioning
| Pièce du modèle | Signification |
| CJX2 | CHINT AC contactor series (equivalent to Schneider LC1‑D series) |
| 32 | Rated operational current 32A (AC‑3 utilization category at 400V) |
| 10 | Contacts auxiliaires: 1 NON + 0 Caroline du Nord |
Positionnement du produit:
Industrial‑grade general‑purpose AC contactor, suitable for frequent starting and control of AC motors.
Can form a magnetic starter with thermal overload relays for motor protection.
- Paramètres techniques clés
| Article | Spécification |
| Tension de fonctionnement nominale | Up to 690V AC (50/60Hz) |
| Rated operational current | 32UN (AC‑3 400V), thermal current Ith = 50A |
| Controlled power | 15kW (AC‑3 380V), 21UN (AC‑3 660V) |
| Contact auxiliaire | 1 NON, rated 5A/220V AC |
| Tension de bobine | Facultatif: 220V/380V/110V/36V/24V AC |
| Insulation characteristics | UI = 660V, compliant with GB14048.4 / IEC60947‑4‑1 |
| Mécanique / electrical life | 10 millions de fois / 1 millions de fois (AC‑3) |
| Dimensions (L×L×H) | 83×58×101 mm |
| Montage | Rail DIN standard de 35 mm |
- Caractéristiques structurelles & Matériels
- Contacts en alliage d'argent: Excellent conductivity and arc resistance, ensuring reliable switching.
- 32‑sheet silicon steel core: Reduces hysteresis loss, smoother pull‑in, stable operation.
- Flame‑retardant housing: Meets V0 flame rating, améliore la sécurité.
- Clear side marking: Modèle, tension, Certification CCC, etc..
- Applications
- Automatisation industrielle: Contrôle du moteur, les fans, pompes, compresseurs.
- Électricité du bâtiment: CVC, pompes à incendie, exhaust fans.
- Agricultural machinery: Irrigation, feed processing equipment.
- Systèmes électriques: Remote circuit control in distribution panels.
- Typical matching: Long‑running oil station motors, unidirectional equipment (no NC auxiliary required).
- Comparison Within CJX2 Series
| Modèle | Courant nominal | Aux. Contacts | AC‑3 380V Power | Dimensions (mm) |
| CJX2‑0910 | 9UN | 1 NON | 4kW | 73×47×82 |
| CJX2‑1810 | 18UN | 1 NON | 7.5kW | 73×47×82 |
| CJX2‑2510 | 25UN | 1 NON | 11kW | 83×58×96 |
| CJX2‑3210 | 32UN | 1 NON | 15kW | 83×58×101 |
| CJX2‑4011 | 40UN | 1 NON + 1 Caroline du Nord | 18.5kW | 128×79×116 |
| CJX2‑6511 | 65UN | 1 NON + 1 Caroline du Nord | 30kW | 128×79×116 |
- Cross‑Brand Replacements
| Marque | Modèle de remplacement | Compatibilité |
| Schneider | LC1N3210M7N / LC1R3210M5N | Mêmes dimensions & paramètres |
| Siemens | 3RT6035‑1AN20 (domestic type) | Fonctionnellement équivalent, mounting compatible |
| ABB | A145‑30‑11 (32A class) | Aux. can be configured as 1 NON |
| Délicieux | CJX2‑3210 | Fully interchangeable |
| Commutateur Changshu | CK3‑3210 | Same performance & paramètres |
- Sélection & Notes d'application
- Tension de bobine: Selected per control circuit (commonly 220V / 380V).
- Correspondance de charge: 32A ≈ 15kW at AC‑3 380V; avoid overload.
- Aux. contact expansion: F4‑11 or similar modules can be added.
- Coordination des protections: Used with NR2 series thermal relays (par exemple. NR2‑36) for overload protection.
- Environnement: Operating temperature ‑5°C ~ +40°C; avoid dust & gaz corrosif.
Emballage: 4 pièces/boîte, 32 pcs/carton
Comparison of CHINT Contactor Series
Aperçu:
CHINT contactors are divided into:
Classique (CJX2/CJ20/CJX8), Mise à niveau (NXC/NC5), High‑Power (NC8), DC Special (CJZ8/NCZ5).
NXC fully replaces CJX2 with better performance; NC5 focuses on intelligence & modularity; NC8 covers ultra‑high current; CJZ8 is for DC control.
Priorité: NXC / NC5; use special series for special applications.
- Series Positioning & Remplacement
| Série | Positionnement | Replaced By / Replaces | Principales fonctionnalités |
| CJX2 | Classic general | Fully replaced by NXC | Rentable, simple structure, flexible aux. contacts |
| NXC | New generation | Replaces CJX2, upgraded | Haute efficacité, longue vie, standard 1NO+1NC, strong modularity |
| NC5 | Smart & premium | Marché haut de gamme | Wide temp ‑25°C~+55°C, communication, complex automation |
| NC8 | High‑power heavy‑duty | Independent, up to 1000A | Up to 1000A AC‑3 415V, for large motors & heavy industry |
| CJX8 | Traditional heavy‑duty | Partially replaced by NC8 | Direct‑operated double break, suitable for legacy retrofits |
| CJ20 | Traditional general | Replaced by NXC/NC5 | Mature structure, faible coût, civil & industrie légère |
| NXC‑XMG | Special load | Independent | For fans & pompes, high energy saving |
| CJZ8/NCZ5 | DC dedicated | Independent | Enhanced arc extinguishing, new energy & energy storage |
- Paramètres techniques clés
2.1 Basic Electrical Data
| Série | Plage actuelle | Tension nominale | AC‑3 380V Power | Standard Aux. Contacts |
| CJX2 | 9UN ~ 95A | Up to 690V | 0.75kW~45kW | Below 32A: 1NO/1NC; ≥40A:1NON+1NC |
| NXC | 6UN ~ 630A | Up to 690V | 0.37kW~315kW | Full range: 1NON+1NC |
| NC5 | 6UN ~ 630A | Up to 690V | 0.37kW~315kW | 1NON+1NC, expandable to 6NO+6NC |
| NC8 | 6UN ~ 1000A | Up to 690V | 0.37kW~500 kW | 2NON+2NC, expandable to 6NO+6NC |
| CJX8 | 9A~250A | Up to 660V | 4kW~110kW | 3NO+1NO/1NC or 4NO |
| CJ20 | 10UN ~ 630A | Up to 660V | 5.5kW~315kW | 1NON+1NC |
2.2 Life & Environnement
| Série | Durée de vie mécanique | Durée de vie électrique (AC‑3) | Operating Temp | Montage |
| CJX2 | 10 million | 1 million | ‑5°C~+40°C | 35mm DIN / vis |
| NXC | 12 million | 1.2 million | ‑25°C~+55°C | 35mm DIN / vis |
| NC5 | 15 million | 1.5 million | ‑25°C~+55°C | 35mm DIN / vis |
| NC8 | 10 million | 0.8 million (courant élevé) | ‑25°C~+55°C | Mainly screw |
| CJ20 | 8 million | 0.8 million | ‑5°C~+40°C | Vis |
- Structure & Différences fonctionnelles
3.1 CJX2 (Classique)
Structure: Direct‑operated single break, modular; F4 aux., F5 timer, NCF1 side aux. disponible.
Contacts: Alliage d'argent, 3P main, flexible aux. (10/01/11).
Bobine: CA/CC, 24V~380V.
3.2 NXC (Mise à niveau)
Optimized magnetic system, coil power ≈ 30% lower than CJX2.
Improved silver alloy contacts, better arc extinguishing.
Standard 1NO+1NC; supports aux., timer, mechanical interlock.
3.3 NC5 (Smart Premium)
Optional communication module (Modbus, etc.) for IIoT.
Wide temperature, suitable for outdoor & harsh environments.
Enhanced insulation & short‑circuit withstand.
3.4 NC8 (High‑Power)
Enhanced arc chamber for high‑current breaking up to 1000A.
Optimized heat dissipation for heavy‑duty continuous operation.
Heavy‑duty mechanical structure, high vibration resistance.
3.5 CJX8 (Traditional Heavy‑Duty)
Direct‑operated double break; front‑connected or rear‑connected versions.
Jusqu'à 4 poteaux (3 principal + 1 aux or 4 principal) for special applications.
3.6 DC Contactors
CJZ8: Low‑voltage DC (12V~220V), up to 40A, small DC loads.
NCZ5: High‑voltage DC (up to 1500V), up to 500A, new energy vehicles & energy storage.
Dedicated DC arc extinguishing structure.
- Scénarios d'application
| Série | Best For | Typical Load | Not Recommended |
| CJX2 | Legacy retrofit, budget projects | Small motors ≤15kW, éclairage, chauffage | High‑end automation, harsh environments |
| NXC | Automatisation industrielle, new projects | Medium motors ≤315kW, les fans, pompes | Ultra‑large motors, special DC loads |
| NC5 | Smart factories, complex systems, de plein air | Moyen & large motors, production lines | Cost‑sensitive simple circuits |
| NC8 | Large industry, pouvoir, métallurgie | Large motors ≤500kW, transformateurs | Small loads, bâtiments civils |
| CJX8 | Legacy maintenance, special control | Traditional machinery, special circuits | New smart projects |
| CJ20 | Civil, industrie légère, temporary power | AC units, pompes, small machines | Frequent switching, high‑end automation |
| DC series | New energy, energy storage, rail | DC motors, batteries, chargeurs | AC loads |
- Guide de sélection & Remplaçants
5.1 Selection Priority
- Nouveaux projets: NXC (replaces CJX2)
- Smart/complex systems: NC5
- Ultra‑high power >315kW: NC8
- DC loads: CJZ8 / NCZ5
- Legacy retrofit: CJX2/CJ20/CJX8 or upgrade to NXC/NC5
5.2 Cross‑Series Replacement
| Original | Recommended Replacement | Avantage |
| CJX2‑09~95 | NXC‑06~100 | Standard 1NO+1NC, life +20%, power ‑30% |
| CJ20‑10~630 | NXC‑12~630 / NC8‑12~1000 | Better performance, modular, easier maintenance |
| CJX8‑09~250 | NC8‑06~250 | Better arc extinguishing, wide temperature |
5.3 Model Selection Tips
Actuel: 32A ≈ 15kW; 63A ≈ 30kW; 100A ≈ 45kW at AC‑3 380V.
Aux. contacts: NXC has 1NO+1NC standard; CJX2 uses 10/01/11.
Bobine: 220V/380V/110V/36V/24V AC/DC.
Montage: 35mm DIN preferred; screw for high power.
- Special Notes: CHINT CJX2‑3210
As a representative model of CJX2 series, CJX2‑3210 is a 3‑pole 32A AC contactor with 3 AUCUN contact principal + 1 PAS de contact auxiliaire, suitable for 15kW motor control at AC‑3 380V.
Common replacements:
CHINT NXC‑3210 (upgraded)
Schneider LC1N3210M7N
Siemens 3RT6035‑1AN20
ABB A145‑30‑11 (32A class)
Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires


















![Le NXC-65 de la série Kunlun de CHINT Electric est un contacteur CA tripolaire, évalué à 65A dans la série NXC. Le modèle complet est généralement exprimé sous la forme NXC-65 [Tension de bobine] [Fréquence] NXC-65 from the Kunlun Series by CHINT Electric is a 3-pole AC contactor, rated at 65A in the NXC series. The full model is typically expressed as NXC-65 [Coil Voltage] [Frequency]](https://www.bestcontactor.com/wp-content/uploads/2026/04/ScreenShot_2026-01-30_132315_324-419x560.png)







NH42-63-318x560.png)