Chint NB1-63/1PC63 miniature circuit breaker (MCB)

Chint NB1-63/1PC63 is a miniature circuit breaker (MCB) with 1 pole (1P), a rated current of 63A, and a Type C tripping curve. It belongs to Chint’s NB1 product series and is suitable for circuits with AC 50Hz and a rated voltage of 230/400V, mainly used for overload and short-circuit protection. I.Core Parameters and Functions 1. Basic ...

  • Product Details

Chint NB1-63/1PC63 is a miniature circuit breaker (MCB) with 1 pole (1P), a rated current of 63A, and a Type C tripping curve. It belongs to Chint’s NB1 product series and is suitable for circuits with AC 50Hz and a rated voltage of 230/400V, mainly used for overload and short-circuit protection.

I.Core Parameters and Functions

1. Basic Specifications

Pole Count: 1P (1 pole), controls only the live wire; the neutral wire is connected directly.

Rated Current: 63A, suitable for high-power load circuits, such as air conditioners and electric water heaters.

Tripping Curve: Type C, applicable to lighting and general inductive loads. The instantaneous tripping range is 5-10 times the rated current (i.e., 315-630A), which can quickly cut off the circuit in case of a short circuit.

Breaking Capacity: 6kA, which can effectively cut off the short-circuit current in the line to ensure safety.

Rated Voltage: 230/400V AC, compatible with single-phase and three-phase systems.

2. Safety Features

Complies with standards such as GB/T 10963.1 and IEC 60898-1, and has obtained certifications including CCC and CE, ensuring reliable quality.

Equipped with overload long-delay protection and short-circuit instantaneous protection functions, which can replace traditional fuses.

The shell is made of high flame-retardant plastic, providing excellent fire resistance. The terminal blocks are designed with anti-misinsertion features to improve installation safety.

II. Installation and Application

1. Installation Method

Adopts standard TH35-7.5mm DIN rail installation, compatible with common distribution boxes for easy installation.

The terminal blocks support a maximum 16mm² copper conductor, with a tightening torque of 2.0N·m to ensure a stable connection.

2. Application Scenarios

Residential Power Distribution: Can be used as the main incoming circuit breaker or branch protection for high-power appliances (such as air conditioners and ovens).

Commercial and Industrial Use: Suitable for circuit protection of loads like lighting and small motors, especially in places where the required short-circuit breaking capacity does not exceed 6kA.

3. Environmental Adaptability

Temperature Range: -35℃ to +70℃, but derating is required when the ambient temperature exceeds 30℃. For example, when the ambient temperature is 60℃, the rated current needs to be reduced to 53.2A (correction factor: 0.84).

Altitude Limit: Can be used normally below 2000m altitude; derating is required above 2000m (e.g., at 2500m, the current is reduced to 56.7A with a correction factor of 0.9).

III. Price and Purchase Recommendations

1. Market Price

Referring to quotes from e-commerce platforms and distributors, the unit price of NB1-63/1PC63 is usually between 11-37 RMB, and may drop to around 10 RMB during promotional activities.

It is recommended to purchase through Chint’s official channel (WhatsApp: 0086-13811255435) to ensure product quality and after-sales service.

2. Alternative Models

For higher breaking capacity (e.g., 10kA), the NB1-63H series (such as NB1-63H/1PC63) can be selected.

For residual current protection function, it can be matched with the NB1LE-63 series residual current operated circuit breakers (such as NB1LE-63 1P+N C63).

IV. Usage Precautions

1. Model Selection and Matching

The rated current should be calculated based on the load power to ensure the circuit breaker capacity is greater than the actual load current. For example, a 63A circuit breaker is suitable for circuits with a maximum power of approximately 14.5kW (230V×63A).

Avoid using NB1-63/1PC63 in DC circuits; the NB1-63DC series should be selected for DC scenarios.

2. Installation Specifications

Power must be cut off before installation, and wiring should be completed by a professional electrician to ensure correct polarity (only controls the live wire).

Regularly check the status of the circuit breaker. If contact ablation or frequent tripping is found, replace it in a timely manner.

V. Certification and Technical Support

Certification Information: Has obtained certifications including CCC, CE, and VDE, complies with international standards, and can be used in most regions around the world.