Disjoncteur miniature Chint NB1-63/1PC63 (MCB) - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Disjoncteur miniature Chint NB1-63/1PC63 (MCB) - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

disjoncteur/

Disjoncteur miniature Chint NB1-63/1PC63 (MCB)

Chint NB1-63/1PC63 is a miniature circuit breaker (MCB) avec 1 pôle (1P.), a rated current of 63A, and a Type C tripping curve. It belongs to Chint’s NB1 product series and is suitable for circuits with AC 50Hz and a rated voltage of 230/400V, mainly used for overload and short-circuit protection. I.Core Parameters and Functions 1. Basique ...

  • Détails du produit

Chint NB1-63/1PC63 is a disjoncteur miniature (MCB) avec 1 pôle (1P.), a rated current of 63A, and a Type C tripping curve. It belongs to Chint’s NB1 product series and is suitable for circuits with AC 50Hz and a rated voltage of 230/400V, mainly used for overload and short-circuit protection.

I.Core Parameters and Functions

1. Spécifications de base

– Nombre de pôles: 1P. (1 pôle), contrôle uniquement le fil sous tension; the neutral wire is connected directly.

– Courant nominal: 63UN, suitable for high-power load circuits, such as air conditioners and electric water heaters.

– Courbe de déclenchement: Tapez C, applicable to lighting and general inductive loads. The instantaneous tripping range is 5-10 fois le courant nominal (c'est-à-dire, 315-630UN), which can quickly cut off the circuit in case of a short circuit.

– Capacité de coupure: 6le, which can effectively cut off the short-circuit current in the line to ensure safety.

– Tension nominale: 230/400V et, compatible with single-phase and three-phase systems.

2. Caractéristiques de sécurité

– Conforme aux normes telles que GB/T 10963.1 et CEI 60898-1, et a obtenu des certifications dont CCC et CE, ensuring reliable quality.

Equipped with overload long-delay protection and short-circuit instantaneous protection functions, which can replace traditional fuses.

The shell is made of high flame-retardant plastic, providing excellent fire resistance. The terminal blocks are designed with anti-misinsertion features to improve installation safety.

II. Installation and Application

1. Méthode d'installation

Adopts standard TH35-7.5mm DIN rail installation, compatible with common distribution boxes for easy installation.

The terminal blocks support a maximum 16mm² copper conductor, with a tightening torque of 2.0N·m to ensure a stable connection.

2. Scénarios d'application

– Distribution d'énergie résidentielle: Can be used as the main incoming circuit breaker or branch protection for high-power appliances (such as air conditioners and ovens).

– Utilisation commerciale et industrielle: Suitable for circuit protection of loads like lighting and small motors, especially in places where the required short-circuit breaking capacity does not exceed 6kA.

3. Adaptabilité environnementale

– Plage de température: -35℃ à +70℃, but derating is required when the ambient temperature exceeds 30℃. Par exemple, when the ambient temperature is 60℃, the rated current needs to be reduced to 53.2A (facteur de correction: 0.84).

– Limite d'altitude: Can be used normally below 2000m altitude; derating is required above 2000m (par ex., at 2500m, the current is reduced to 56.7A with a correction factor of 0.9).

III. Recommandations de prix et d'achat

1. Prix ​​du marché

Referring to quotes from e-commerce platforms and distributors, the unit price of NB1-63/1PC63 is usually between 11-37 RMB, and may drop to around 10 RMB during promotional activities.

It is recommended to purchase through Chint’s official channel (WhatsApp: 0086-13811255435) to ensure product quality and after-sales service.

2. Modèles alternatifs

– Pour un pouvoir de coupure plus élevé (par ex., 10le), the NB1-63H series (such as NB1-63H/1PC63) peut être sélectionné.

For residual current protection function, it can be matched with the NB1LE-63 series residual current operated circuit breakers (such as NB1LE-63 1P+N C63).

IV. Précautions d'utilisation

1. Model Selection and Matching

The rated current should be calculated based on the load power to ensure the circuit breaker capacity is greater than the actual load current. Par exemple, a 63A circuit breaker is suitable for circuits with a maximum power of approximately 14.5kW (230V×63A).

Avoid using NB1-63/1PC63 in DC circuits; the NB1-63DC series should be selected for DC scenarios.

2. Spécifications d'installation

Power must be cut off before installation, and wiring should be completed by a professional electrician to ensure correct polarity (contrôle uniquement le fil sous tension).

– Vérifier régulièrement l'état du disjoncteur. If contact ablation or frequent tripping is found, replace it in a timely manner.

V. Certification et support technique

– Informations sur les certifications: Has obtained certifications including CCC, CE, et VDE, complies with international standards, and can be used in most regions around the world.

– Documents techniques: Product manuals, guides d'installation, and certification certificates can be downloaded from Chint’s official website to obtain detailed parameters and usage instructions.

Précédent:

Suivant:

Laisser une réponse

Laisser un message