Mitsubishi AJ65SBTB1-16D Remote I/O Unit Series

AJ65: CC-Link remote I/O unit series SBT: CC-Link remote module B1: Compact terminal block type 16D: 16-point DC digital input module (Entrée numérique) Positionnement: CC-Link remote input station, occupant 1 station address. It is used for remote DI signal acquisition, compatible with Q/A/L series master PLCs, and is one of the most widely used remote ...

  • Détails du produit

AJ65: CC-Link remote I/O unit série

SBT: CC-Link remote module

B1: Compact terminal block type

16D: 16-point DC digital input module (Entrée numérique)

Positionnement: CC-Link remote input station, occupant 1 station address. It is used for remote DI signal acquisition, compatible with Q/A/L series master APIs, and is one of the most widely used remote DI modules for CC-Link fieldbus.

Spécifications techniques de base

ArticleParamètre
Points d'E/S16-point d'entrée DC24V
Note d'entréeDC24V; allowable voltage range: DC19.2~26.4V, ondulation ≤5%; input current per point approx. 7mAMITSUBISHI…
ON Condition≥14V / ≥3.5mA; OFF Condition: ≤6V / ≤1.7mAMITSUBISHI…
Input Response Time≤1,5ms (ON↔OFF)
Borne communeSink/source compatible (supports both NPN and PNP sensors); 1 common terminal for all 16 points; single-row terminal block
IsolementPhoto-coupler isolation
Occupation de la gare1 station
Alimentation du moduleDC24V; consommation d'énergie environ. 35mAMitsubishi…
Dimensions hors toutW118 × H50 × D40 mm; poids environ. 0.18kgMitsubishi…
Conditions ambiantesTempérature de fonctionnement: 0~55℃; température de stockage: -20~75℃; humidity 10~90%RH (pas de condensation)
CertificationsUL, cUL, CE, RoHS, KC

Directives de câblage

  1. Bornier: 16 Canaux DI + COM terminal. COM supports both positive and negative common, so NPN and PNP sensors can be wired directly.
  2. Bus terminals: ET, Base de données (CC-Link signal lines) + FG shield earth.
  3. Alimentation: Module powered by DC24V. Use the same power supply for the module and sensors, and keep common ground.
  4. Terminating resistor: Install 110Ω CC-Link terminating resistor at the first and last stations on the bus.
  5. Station address setting: Set the CC-Link station number (1~64) via the DIP switch on the side of the module; settings take effect after power cycle.

Scénarios d'application

Distributed DI acquisition on production lines: Capteurs photoélectriques, détecteurs de proximité, boutons-poussoirs, limit switches and E-stop signals collected remotely.

Cabinet split wiring: Main PLC installed in central control cabinet; AJ65SBTB1-16D mounted locally on equipment control boxes to eliminate long-distance multi-core cables, only one CC-Link bus cable is needed.

Compatible master stations: Q, UN, L series PLCs (with CC-Link master modules QJ61BT11N / AJ61BT11, etc.)

Logiciel de programmation: GX fonctionne2 / GX fonctionne3. Configure remote I/O stations in CC-Link network parameters; remote input soft elements are assigned automatically.

Dépannage

  1. RUN indicator off: Check DC24V power supply and polarity.
  2. LERR indicator flashing: Duplicate station number, bus breakage, DA/DB reversed, résistance de terminaison manquante, or communication interference.
  3. No input signal: Check sensor power supply, COM wiring, input voltage, or damaged optocoupler.
  4. Input permanently ON: Shorted sensor or short circuit to ground on field wiring.

Remplacement & Cross-model Reference

AJ65SBTB1-16D1: 16DI with faster 0.2ms response (high-speed version).

AJ65SBTB1-32D: 32-point DC input (same series, 1 station occupied).

AJ65SBTB1-16DT: Mixed 8DI+8DO I/O module.

New generation replacement: NZ2GF2B1-16D (CC-Link IE Field Basic remote DI, recommandé pour les nouveaux projets).

Engineering Application Cases for AJ65SBTB1-16D

Positionnement de base: 16-point DC24V digital input remote station over CC-Link, distributed field DI collection to reduce extensive hardwiring. Compatible master stations: Q/L/A series PLC + QJ61BT11N, FX3U+FX3U-16CCL-M, FX5+FX5-CCL-MS; one module occupies one CC-Link station address.

Cas 1: Pushrod Accumulating Conveyor with Wire Breakage Detection (Diagnostic Type)

  1. Transistor Output Modules (FAIRE, T=Transistor, Sink/NPN Type)

8-point Output

  1. AJ65SBTB1-8T: 8-sortie transistor ponctuelle, 1.5réponse de Mme
  2. AJ65SBTB1-8T1: 8-point low leakage current version
  3. AJ65SBTB1-8TE: 8-point with protective circuit

16-point Output

  1. AJ65SBTB1-16T: 16-point standard transistor output
  2. AJ65SBTB1-16T1: 16-point low leakage current version

32-point Output

  1. AJ65SBTB1-32T: 32-sortie transistor ponctuelle
  2. AJ65SBTB1-32T1: 32-point low leakage current
  3. AJ65SBTB1-32TE1: 32-point enhanced protection version

III. Modules d'E/S mixtes (DI+DO, DT=Input+Output)

16-point Mixed (8J+8C)

  1. AJ65SBTB1-16DT: Standard 8DI+8DO
  2. AJ65SBTB1-16DT1: High-speed response version
  3. AJ65SBTB1-16DT2: With wire breakage diagnosis
  4. AJ65SBTB1-16DT3: High-reliability revised version (most popular new model)

32-point Mixed (16J+16C)

  1. AJ65SBTB1-32DT: Standard 16DI+16DO
  2. AJ65SBTB1-32DT1: High-speed version
  3. AJ65SBTB1-32DT2: With wire breakage detection (KDT type)
  4. AJ65SBTB1-32KDT2: Wire breakage diagnosis + protection contre les courts-circuits
  5. AJ65SBTB1-32KDT8: 32-point mixed, high diagnostic grade
  6. AJ65SBTB1-32DT3: Revised stable model
  7. AJ65SBTB1-32DTE1: With surge absorption protection-
  8. Suffix Code Rules (Identification rapide)

Pas de suffixe: Standard response time 1.5ms

1: Réponse à grande vitesse (0.2MS); low leakage current output

2: Wire breakage diagnosis function

3: Revised circuit, improved anti-interference performance

K: Wire breakage detection (diagnostic module)

E: Output surge protection added

  1. Distinction Between Adjacent Series (Avoid Wrong Selection)
  2. AJ65SBTB1: Single-row terminal block, compact type (this series)
  3. AJ65SBTB2: Double-row terminals, higher output current
  4. AJ65SBT32: Large-size 32-point remote I/O
  5. AJ65SBTC1/C4: Spring-cage terminals (type de plug-in, not part of TB1 series)
  6. Simplified Selection Table for Project Use
ApplicationModèle préféréHigh-speed Alternative
16-point DI collectionAJ65SBTB1-16DAJ65SBTB1-16D1
32-point DI collectionAJ65SBTB1-32DAJ65SBTB1-32D1
16-point DO outputAJ65SBTB1-16TAJ65SBTB1-16T1
8DI+8DO mixed I/OAJ65SBTB1-16DT3AJ65SBTB1-16DT2
16DI+16DO mixed I/OAJ65SBTB1-32DT3AJ65SBTB1-32KDT2