Numéro d'article.: 229188
AS‑Interface V3.0 Handheld Addressing Programming Kit (Complete Toolbox Set for AS‑i Handheld Unit)
Application: On-site addressing, diagnostic reading, I/O testing and offline commissioning of AS‑i slaves (capteurs, actionneurs, safety modules); supports independent commissioning of AS‑i nodes without PLC connection.
- Model Variants
- VBP-HH1-V3.0: Handheld main unit only (bare unit), Item No. 221095
- VBP-HH1-V3.0-KIT: Complete toolbox set (model you inquired)
- VBP-HH1-V3.0-KIT-110V: Variant with different charger (110V North American version)
- Fonctions principales
Compliant with AS‑Interface V3.0 standard, supports A/B extended addressing slaves (maximum. 62 nœuds)
Supports AS‑i Safety at Work safety slaves (Profile S‑0.B / S‑7.B / S‑7.7.A.7)
Slave addressing, semi-automatic address assignment, ID/ID1/ID2 reading
Real-time input signal monitoring, forced output, on-site I/O function test
Fault code and peripheral diagnostic data reading
Short-circuit and overload protection; built-in power supply to power slaves independently for commissioning (no need to connect main AS‑i loop)
Optional optical interface for commissioning
- Key Electrical Specifications
| Article | Paramètre |
| Bus Standard | AS‑Interface Specification V3.0 |
| Afficher | LCD liquid crystal display |
| Clavier | 5-key membrane keypad |
| Alimentation | Built-in rechargeable battery; multi-plug charger included |
| Battery Life | Environ. 8 heures de fonctionnement continu; ≥250 read/write cycles |
| Temps de charge | Environ. 14 hours for full charge |
| Open-circuit Voltage | 28 À DC |
| Charge de sortie | Max.. 100 mA @ 25 V |
| Classe de protection | IP20 (only suitable for control cabinet / indoor field use) |
| Matériau du boîtier | Engineering plastic |
- Standard Contents of V3.0-KIT Set
- VBP-HH1-V3.0 Handheld Main Unit
- VAZ-PK-1.5M-V1-G Addressing Cable (with M12 connector)
- Multi-country interchangeable plug power charger (EU/US/UK/AU)
- Hard protective carrying toolbox
- Printed operation manual
- Scénarios d'application typiques
AS‑i bus commissioning for automotive welding lines, logistics sorting and packaging machinery
Address configuration for safety light curtains, safety relays and AS‑i emergency stop modules
On-site commissioning for new projects, equipment maintenance and re-addressing after spare part replacement
Production line retrofitting and batch modification of AS‑i slave addresses
- Common Precautions & Fault Tips
- ❗ Only use original matching charger for charging; third-party power supplies are prohibited
- Confirm no personnel are on-site before forcing outputs when commissioning safety slaves to avoid accidental movement
- Slave detection failure: Check polarity and bus distance; verify reliable piercing connection for flat cables
- Battery ageing: Charge every 3 months during long-term storage
- Incompatible with some special legacy AS‑i V2.1 models (confirm slave profile prior to use)
- Informations de remplacement
No direct domestic compatible handheld programmers available; only original Pepperl+Fuchs units can be procured as spare parts.
Statut de production: Actif, not obsolete; typical lead time 4–6 weeks
If required, I can provide:
Chinese translation of key pages from official Datasheet
Standard AS‑i slave addressing operation procedures
List of common error codes
Summary of ordering models for matching addressing cables
Language Support for VBP-HH1-V3.0 (Including KIT Set)
Key Conclusion
✅ The LCD operation interface only supports two languages: Allemand (Deutsch), Anglais (Anglais)
❌ No Chinese menu; firmware flashing or additional Chinese language packs are not supported; japonais, French, Spanish and other languages are unavailable
Informations supplémentaires
- Factory Default Language: Anglais
- Language Switch Path
Power on → MODE to enter setting menu → Language → Select between German / Anglais
- Distinguish two easily confused concepts
On-screen text of handheld unit: Only German & Anglais
Paper manuals/PDF documents: Multi-language versions (including Chinese) can be downloaded from Pepperl+Fuchs official website, but cannot be imported into the handheld unit
Foire aux questions
- Can firmware be upgraded to add Chinese language?
Official firmware does not support Chinese, and no third-party localization solution exists. English interface is widely adopted for on-site commissioning in China.
- Does the older VBP-HH1-V3.0-V1 version support the same languages?
Cohérent; only German and English, no Chinese available.
Simplified English Menu Reference for On-site Operation
ADR: Adressage
PRG: Parameter Programming
IO: Input/Output Monitoring
PERI: Peripheral Diagnosis
DATA: Slave ID Data Reading
Compatibility Scope of VBP-HH1-V3.0 (KIT Set) – Core Conclusion
Compatibility is not limited by sensor model, but governed by the [AS‑Interface V3.0 protocol standard]
✅ All AS‑i slaves complying with AS‑i Spec V2.1 / V3.0 (all brands supported) can be addressed and commissioned;
❌ ASi‑5 (AS‑i 5.0) new-generation slaves are not supported.
- Supported Device Categories (Multimarque: Pepperl+Fuchs, Bihl+Wiedemann, Siemens, Ifm etc.)
1) Standard Digital AS‑i Slaves
AS‑i proximity sensors, capteurs photoélectriques, magnetic switches (integrated AS‑i M12 interface)
4DEPUIS, 4FAIRE, 4D/4C, 2DI/2DO modules
Fully compatible with A/B extended addressing slaves (1A~31A / 1B~31B, maximum. 62 nœuds)
2) ASIsafe Safety Slaves (Officially Supported Profiles)
S‑0.B / S‑7.B / S‑7.7.A.7
AS‑i emergency stop pushbuttons
Safety door switches, safety hinges
AS‑i safety light curtains / light grids
Safety relay modules, F‑DI safety input modules
3) Analog AS‑i Slaves
AS‑i 4…20 mA, 0–10 V analog input/output modules
Temperature transmitters, capteurs de pression (AS‑i analog variants)
4) Actuator Devices
AS‑i solenoid valve modules, pneumatic valve island AS‑i interface modules
- Common Compatible Pepperl+Fuchs Sensor Series
- VariKont M Series (M12 integrated AS‑i sensors)
NBB, NBN, NJ series AS‑i models (par exemple. NBB4‑12GM30‑AS‑I)
- VariKont S, FP flat cable integrated AS‑i sensors
- Module Series:
G1, G4, G16 series AS‑i I/O modules (VBG‑G4, VBG‑G16, etc.)
- ASIsafe Safety Products:
VBG‑F series safety modules, AS‑i safety door switches, AS‑i emergency stop
- Wiring Classification (Critical for On-site Commissioning)
- Sensors with M12 addressing port
→ Directly use standard cable included in kit VAZ‑PK‑1.5M‑V1‑G
- Flat cable piercing AS‑i sensors (no independent addressing socket)
→ Adapter required; cannot connect directly to handheld unit
- Third-party B+W, Siemens AS‑i modules
Normal addressing, ID reading and I/O monitoring as long as equipped with standard AS‑i addressing port
- Important Limitations & Éviter les pièges
- ASi‑5 (AS‑Interface 5.0) not supported
New models such as BW4708 and Siemens ASi‑5 modules cannot be identified;
- Rare legacy AS‑i V2.0 slaves (non-V2.1) carry compatibility risks;
- Available functions only: Adressage, ID reading, I/O monitoring, forced output, basic diagnosis;
Advanced parameter configuration (filtering, PID for intelligent sensors) depends on whether the slave opens standard AS‑i parameter channels;
- For analog slaves: Only basic communication testing available; complex range calibration requires original manufacturer software
- Universal Quick Judgment Rule
Check the nameplate of any AS‑i sensor/module:
Marked AS‑Interface V2.1 / V3.0 → Compatible with VBP‑HH1‑V3.0
Marked ASi‑5 / AS‑Interface 5.0 → Not compatible
Full List of Supported Pepperl+Fuchs AS‑i Sensors for VBP-HH1-V3.0 (V3.0-KIT)
Core Judgment Principle (Most Important)
This handheld unit is not restricted by sensor model, but complies with bus standards
✅ All Pepperl+Fuchs integrated AS‑i sensors and AS‑i modules compliant with AS‑Interface V2.1 / V3.0 are fully supported
❌ ASi‑5 (AS‑Interface 5.0) new-generation devices are unsupported
❌ Ordinary 3-wire switching sensors (without AS‑i bus interface) cannot be addressed
Models suffixed with ‑AS‑I / B3B = AS‑i bus type and supported; ordinary suffixes such as ‑E0 / E2 / V1 denote standard sensors without bus function and cannot be addressed.
- Pepperl+Fuchs Integrated AS‑i Inductive Proximity Sensors (Entièrement compatible)
1.1 VariKont M Series (Cylindrical M12/M18/M30, equipped with M12 addressing socket, direct connection with kit standard cable)
Typical model examples:
NBB4‑12GM50‑AS‑I
NBB8‑18GM50‑AS‑I
NBB20‑U1‑B3B (M30, V3.0 A/B dual-address slave)
NBN4‑12GM40‑AS‑I
NBN8‑18GM40‑AS‑I
1.2 VariKont S / FP Flat Cable Integrated AS‑i Sensors (Piercing wiring, no M12 addressing port)
Additional flat cable addressing cable VAZ‑PK‑FK‑0.2M‑V1‑W required; kit standard cable cannot be used directly
Representative models:
NBB5‑18GK50‑AS‑I, NBN10‑20GK50‑AS‑I, FP series AS‑i flat cable sensors
- AS‑i Photoelectric Sensors (VISOLUX Series ‑AS‑I Models)
All photoelectric switches suffixed with ‑AS‑I:
RLK31‑8‑2500‑IR‑AS‑I
VT18‑8‑400‑AS‑I
OBT500‑18GM60‑AS‑I
- ASIsafe Safety Sensors & Safety Switches (Officially Supports S‑0.B / S‑7.B Safety Protocol)
- AS‑i safety door switches, safety hinges
LIM series safety locking switches such as VAA‑2E3A‑LIM1‑PL‑J‑S‑V1
- AS‑i emergency stop modules, safety input modules
- AS‑i safety light curtain supporting ASIsafe slave modules
⚠️ Handheld unit only supports addressing and status reading; safety parameter configuration is recommended to be verified via gateway software
- AS‑i I/O Modules (All Common Series Supported)
Digital Modules
G4 Series: VAA‑4E‑G4‑ZE, VAA‑4E4A‑G4‑ZE, VBA‑4E2A‑G4
G10 Series: VBA‑2E‑G10‑ZAJ
G11 Series, G16 Series, KE1 DIN rail modules: VBA‑4E‑KE1‑Z
G20 MDR roller drive modules
Analog AS‑i Modules (4…20mA, PT100 Temperature)
VBA‑2E‑G11‑I/U/PT100‑F, VBA‑4E‑G4‑PT100
Handheld unit only supports addressing and communication test; range calibration cannot be completed with handheld unit; upper computer software is required
- Wiring Classification for On-site Commissioning
- Devices with M12 circular addressing socket (VariKont M)
Use kit standard cable: VAZ‑PK‑1.5M‑V1‑G, prêt à l'emploi
- FP flat cable piercing AS‑i sensors
Additional flat addressing cable required: VAZ‑PK‑FK‑0.2M‑V1‑W
- DIN rail AS‑i modules
Most modules come with built-in M12 addressing port for direct connection; older terminal-style modules require adapters
- Unsupported Pepperl+Fuchs Product List
- All ASi‑5 new-generation modules (marked AS‑Interface 5.0 on model)
- Legacy AS‑i V2.0 early slaves (small stock; risk of identification failure)
- NAMUR intrinsically safe sensors, ordinary 3-wire proximity sensors (without AS‑I bus interface)
- Intelligent identification sensors (RFID, barcode readers without AS‑i V3.0 protocol variant)
Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires















NH42-63-318x560.png)