Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Relais intelligent compact Schneider SR2A201FU - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

électrique/

Relais intelligent compact Schneider SR2A201FU

ItemParamètre
Type de produitCompact Smart Relay
SérieZelio Logic SR2
I/O Configuration12 discrete inputs + 8 sorties relais (20 I/O points in total)
Power Supply Voltage100~240V AC, 50/60HZ
Display FunctionEquipped with LCD screen and navigation buttons
Clock FunctionNo built-in real-time clock
Méthode de montage35mm standard DIN rail mounting
Classe de protectionIP20 (front panel), IP40 (overall)
Température de fonctionnement-20℃ ~ +55℃
Storage Temperature-40℃ ~ +70℃
Période de garantie18 mois

  • Détails du produit

Complete Technical Guide for Schneider SR2A201FU Compact Smart Relay

The Schneider SR2A201FU is a compact smart relay belonging to the Zelio Logic series. It integrates basic PLC functions with the advantages of relay control, and is suitable for logic control, remote management and monitoring of simple automation systems. The following is the complete technical parameters, caractéristiques fonctionnelles, application scenarios and model selection & replacement solutions.

  1. Core Product Overview
ItemParamètre
Type de produitCompact Smart Relay
SérieZelio Logic SR2
I/O Configuration12 discrete inputs + 8 sorties relais (20 I/O points in total)
Power Supply Voltage100~240V AC, 50/60HZ
Display FunctionEquipped with LCD screen and navigation buttons
Clock FunctionNo built-in real-time clock
Méthode de montage35mm standard DIN rail mounting
Classe de protectionIP20 (front panel), IP40 (overall)
Température de fonctionnement-20℃ ~ +55℃
Storage Temperature-40℃ ~ +70℃
Période de garantie18 mois
  1. Detailed Technical Parameters

(je) Input Characteristics

ParamètreSpécification
Number of Input Points12 discrete input points
Input TypeC.C 24 V (standard), compatible with NPN/PNP signals
Input CurrentApproximately 7mA per point
Temps de réponse≤10ms
Isolation MethodPhotoelectric isolation, 2500V et

(Ii) Output Characteristics

ParamètreSpécification
Number of Output Points8 relay output points
Type de contactNormalement ouvert (NON), C-type contacts (optional)
Courant nominalMaximum 8A per point, for AC-1 category loads
Tension nominaleMaximum 250V AC / 30À DC
Durée de vie mécanique≥10 million operations
Electrical Service Life≥100 000 opérations (at rated load)
Surge ProtectionBuilt-in RC snubber circuit

(III) Control Functions

FonctionSpécification
Programming MethodDiagramme en échelle, supports 0~240 logic lines
Built-in Function Blocks16 timers, 16 counters, shift registers, comparators, etc..
MemoryBuilt-in EEPROM flash memory, data retention up to 10 années
Interface de communicationSupports USB/Bluetooth communication expansion via SR2USB01 or SR2BTC01 module
Program CapacityCan store multiple programs, supports program copying to other SR2 relays

III. Caractéristiques fonctionnelles de base

  1. Conception intégrée: Integrates PLC logic control and relay output, meeting small-to-medium-sized control requirements without additional expansion modules.
  2. Easy Programming: Supports ladder diagram programming. On-site editing, monitoring and fault diagnosis can be performed via the built-in LCD screen and navigation buttons, eliminating the need for a dedicated programmer.
  3. Flexible Adaptability: Wide voltage power supply (100~240V AC) is compatible with power grids worldwide, and DC 24V input is compatible with industrial sensor signals.
  4. Reliable and Durable: Industrial-grade design with strong anti-electromagnetic interference capability, adapté aux environnements industriels difficiles.
  5. Data Security: Built-in EEPROM memory ensures no program or data loss after power failure, with a backup cycle of up to 10 années.
  6. Cost Optimization: Replaces traditional relay control cabinets, reduces wiring complexity, and lowers maintenance costs and potential fault points.
  7. Scénarios d'application typiques
  8. Contrôle du moteur: Start-stop, forward-reverse rotation, star-delta reduced-voltage starting and other self-locking and interlocking control for single/three-phase motors.
  9. Systèmes de pompes et de vannes: Logic control and protection for water supply and drainage, hydraulic and pneumatic systems.
  10. HVAC Control: Interlocking control of temperature/pressure/flow for fans, compressors and air conditioning systems.
  11. Lighting Management: Timed lighting, zoning control and energy-saving management for industrial plants and commercial buildings.
  12. Equipment Interlocking: Sequence control, counting, time delay and interlocking protection for simple processes in production lines.
  13. Remote Monitoring: Realize remote monitoring and control of equipment operating status through communication modules.
  14. Programming and Commissioning Methods
  15. On-site Programming: Directly perform logic editing, parameter setting and fault diagnosis via the built-in LCD screen and navigation buttons.
  16. Software Programming: Use the Zelio Soft dedicated programming software (including Discovery Package learning version), which supports ladder diagram editing, simulation and program upload/download.
  17. Communication Expansion:

SR2USB01: USB communication module, enabling high-speed data transmission between PC and relay.

SR2BTC01: Bluetooth communication module, supporting wireless programming and monitoring.

  1. Fault Diagnosis: The LCD screen displays real-time I/O status, timer/counter values and fault codes, facilitating quick problem location.
  2. Model Selection, Replacement and Cross-brand Alternatives

(je) Schneider Same-series Alternatives

ModèleDifferencesScénarios d'application
SR2A101FUNo LCD screenCost-sensitive fixed control scenarios that do not require on-site programming
SR2A201FWWith real-time clockApplications requiring timing control and time recording
SR2B201FU8 inputs + 4 sorties relaisScenarios with fewer I/O point requirements
SR2B201FW8 inputs + 4 sorties relais + clockSimple timing control scenarios

(Ii) Cross-brand Alternative Solutions

MarqueModèleCompatibilitéRemarques
ChintNX-SR Series Smart Relays★★★☆☆Similar functions, I/O points need to be matched accordingly
DélicieuxCDSR Series★★★☆☆Compatible with basic logic control functions
OmronCP1E Series Micro PLC★★★★☆More abundant functions, programming software needs to be adapted
SiemensLOGO! Série★★★★☆Same type of compact smart relay with different communication protocols

VII. Installation and Wiring Key Points

  1. Emplacement d'installation: Mount on 35mm standard DIN rail, reserve ≥50mm heat dissipation space, and avoid high temperature, humidity, dust and strong electromagnetic interference environments.
  2. Power Supply Wiring: Connect L/N to 100~240V AC power supply, and ensure the PE terminal is reliably grounded.
  3. Input Wiring:

Connect the common terminal (COM) to the negative pole of DC 24V.

Connect input points to the positive pole of sensor signals, with a response time ≤10ms.

  1. Output Wiring:

The common terminal (COM) of relay outputs can be connected to AC 220V or DC 24V power supply.

Maximum load of 8A per point; pour charges inductives, a freewheeling diode (CC) or RC snubber circuit (CA) must be connected in parallel.

  1. Communication Wiring: Realize USB/Bluetooth communication through expansion modules, with communication cable length ≤5m.

VIII. Common Fault Troubleshooting

Phénomène de défautCauses possiblesTroubleshooting Methods
Power indicator not litPoor power connection/abnormal voltage/damaged power moduleCheck power wiring and voltage, replace the power module
No input responseAbnormal input signal/wiring error/damaged input pointMeasure input signal, check wiring, replace the input point
No output actionDamaged output point/load short circuit/logic errorCheck load and wiring, simulate and test logic with Zelio Soft
Program lossEEPROM fault/abnormal power failureCheck power stability, re-download the program
Communication failurePoor connection of communication module/incorrect software settingsCheck module connection, confirm communication parameter matching
  1. Safety and Maintenance Suggestions
  2. Safe Operation: Programming and wiring must be performed under power-off conditions to avoid electric shock risks.
  3. Regular Maintenance:

Inspect wiring terminals for looseness and clean dust on the equipment surface every quarter.

Test I/O point response and relay contact reliability every year.

  1. Program Backup: Regularly back up programs via Zelio Soft software to prevent data loss.
  2. Spare Parts Reserve: It is recommended to reserve spare relays of the same model for critical applications to shorten fault downtime.

Précédent:

Suivant:

Laisser une réponse

Laisser un message