Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

Controller bruciatore Honeywell Satronic MMG810.1 - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

NotiziaNotizie commerciali

Controller bruciatore Honeywell Satronic MMG810.1

Controller bruciatore Honeywell Satronic MMG810.1

Controller bruciatore Honeywell Satronic MMG810.1

  1. Brand Clarification & Posizionamento del prodotto

The MMG810.1 is not a Rockwell product. It is a two-stage forced-draft combined oil/gas burner control unit under the Satronic brand by Honeywell, conforme alla norma EN 298, used for automatic safety control and monitoring of burners.

Rockwell’s Micro810 is a micro PLC controller for general industrial automation, with a different function from this dedicated burner controller.

  1. Core Function Positioning

The MMG810.1 acts as the “safety brain” of the burner. Its main functions include:

  1. Full-automatic combustion control: Implements a complete automatic sequence from startup to shutdown
  2. Multiple safety protections: Monitors key parameters during combustion to ensure safe operation and prevent explosion and fire risks
  3. Flame detection and supervision: Compatible with various flame detection technologies to judge flame status in real time
  4. Fault diagnosis and alarm: Records and indicates fault causes for quick troubleshooting
  5. Principio di funzionamento & Control Sequence

The MMG810.1 uses microprocessor control and follows strict combustion safety sequences:

Control StageDescrizioneTiming
Pre-purgeStarts blower to purge residual flammable gases from the combustion chamberStandard 45 secondi, adjustable
Ignition PreparationActivates ignition transformer to generate high-voltage spark3 seconds pre-ignition
Main Fuel SupplyOpens main fuel valve and monitors flame establishmentIgnition safety time (typically 2–5 seconds)
Funzionamento normaleContinuously monitors flame, pressure, temperature, ecc., and automatically regulates combustionContinuous until shutdown command
Post-purgeCloses fuel valve and keeps blower running to purge residual gasesStandard 10 secondi, adjustable
Fault ShutdownImmediately cuts fuel supply upon abnormality and enters alarm stateInstant response
  1. Key Technical Specifications & Caratteristiche
ArticoloValoreNote
Supply Voltage220/240V e (-15%~+10%), 50/60HzBuilt-in undervoltage protection (cutoff at 160V, auto-restart at 180V)
Control TypeTwo-stage forced-draft combined oil/gas burnerSuitable for burners of any rated power
Flame DetectionIonization electrode, UV sensor (UVZ 780), IR flicker detector (IRD 1020.1)Adapts to different fuels and combustion conditions
Output RatingRelay output, max. 10UNControls fuel valves, blower, ignition transformer, ecc.
Protection DegreeIP40Dust-proof, adatto per ambienti industriali
Extra FunctionsProtezione da sottotensione, damper control, fault memory, remote resetImproves reliability and usability
  1. Applicazioni tipiche

The MMG810.1 is widely used in equipment and facilities requiring safe and reliable combustion control:

  1. Industrial Heating Equipment

Combustion control for boilers, furnaces, kilns: steam boilers, hot water boilers, industrial kilns

Drying equipment, curing ovens, heat treatment furnaces for precise temperature control and safety

  1. Commercial & Residential Heating Systems

Heating boilers for large buildings: uffici, hotels, hospitals

Permanent air heaters (direct air heaters conforming to DIN 4794)

Baking ovens, sterilization equipment in food processing

  1. Special Applications

Reactor heating systems in chemical industry with strict combustion control

Incinerator control for waste treatment to prevent toxic gas leakage

Agricultural drying equipment: essiccatoi per cereali, tobacco dryers

  1. Core Safety Protection Functions

The MMG810.1 provides comprehensive safety and is an essential component for burners:

  1. Flame failure protection: Immediately cuts fuel if flame is lost to prevent explosive accumulation
  2. Pressure monitoring: Monitors air pressure (air pressure switch) and fuel pressure; shuts down on abnormality
  3. Protezione da sottotensione: Shuts down below 160V, restarts above 180V to avoid equipment damage
  4. Overtemperature protection: Works with temperature sensors to prevent overheating
  5. Valve leak check: Tests fuel valve tightness before startup to ensure no leakage
  6. Competitive Advantages & Condizioni operative
  7. Vantaggi fondamentali

High versatility: Suitable for forced-draft oil/gas burners of any power rating

Multi-detection compatibility: Supports various flame detection methods for different fuels

Strict safety standard: Complies with EN 298 for burner controls and certified

Easy maintenance: Fault code indication for fast diagnosis and repair

  1. Condizioni operative

For forced-draft combustion systems (not natural draught)

Supports two-stage combustion control (high/low fire) for variable loads

Suitable for dual fuel oil/gas burners with fuel switching capability

Temperatura ambiente: -20℃~+60℃, umidità ≤95% (non-condensing)

As a professional burner controller from Honeywell Satronic, the MMG810.1 is a critical safety component for industrial and commercial combustion systems.

Through precise sequence control, multiple safety protections, and real-time monitoring, it ensures safe, affidabile, and efficient combustion, widely applied in all kinds of heating equipment.

Complete Application Scenarios for Rockwell Micro810

(Core Position: 12-point I/O smart relay + micro PLC)

One-sentence positioning:

The Micro810 is a compact micro PLC from Rockwell’s Micro800 series, designed for standalone or small coordinated control within 10–20 I/O points with simple to medium complexity.

It features 8A high-current relay outputs (no external relays needed), on-board LCD programming, and fast USB deployment.

It is a cost-effective replacement for traditional relay control, ideal for small-space, low-cost, fast-implementation automation projects.

  1. Key Adaptable Features
FeatureSpecificaValue for Applications
Configurazione I/OStandard 12 punti (8 inputs + 4 outputs), expandableCovers basic small-machine control without extra cabinet space
Output Capacity4×8A high-current relay outputsDirectly drives fans, pumps, heaters; saves relays and cost
ProgrammingOn-board 1.5” LCD + keypad / USB PC programmingOn-site parameter modification without specialist staff
ComunicazioneBuilt-in EtherNet/IP, Modbus RTU/TCPConnects HMI, inverters, sensors for small coordinated systems
AmbienteOperating temp -20℃~+60℃, vibration-resistantSuitable for harsh industrial environments, outdoor or workshop
  1. Six Core Application Scenarios
  2. Replacement of Traditional Relay‑Contactor Control (Primary Use)

Why suitable:

One Micro810 replaces 5–8 hardwired relays + timer, reduces wiring faults, improves logic flexibility, and greatly lowers panel cost and size.

Typical ses:

Small production line start/stop logic (photoeye → conveyor → delay sealing)

Equipment interlock protection (machine door open → stop; overload → alarm)

Timing/delay control (workshop lighting schedule, equipment preheat delay)

Examples: Small packaging machines, punch presses, shearing machines.

  1. Automation for Small Standalone Equipment

Official core applications (per Rockwell website):

CategoriaApplicationControl Logic
Lighting ControlZoned lighting for workshops, warehouses, parking lots; streetlight schedulingLight sensor + timer; on with presence, off when empty
Temp & Humidity ControlSmall ovens, incubators, server room HVACSensor → PID → fan/heater control
Compressor ControlSmall air compressors, refrigeration unitsPressure threshold control, high/low pressure protection
Elevator / EscalatorSmall freight elevators, shopping mall escalatorsTraffic detection + safety interlock for energy saving
  1. OEM Equipment Mass Production

Why suitable:

Supports user-defined function blocks (UDFB) and Micro800 ecosystem, enabling fast, standardized control for OEM machines.

Typical uses:

Packaging machinery: Vertical form-fill-seal machines, heat shrink sleeve labelers

Material handling: Small belt conveyors, roller lines, sorting stations

Agricultural equipment: Small irrigation, greenhouse climate control, feed mixers

Medical equipment: Small sterilizers, reagent refrigerators, simple assembly lines

  1. Small Data Acquisition & Monitoraggio remoto

Why suitable:

Supports Modbus / EtherNet/IP for connecting sensors and instruments, enabling data acquisition + local control.

Typical uses:

Workshop environment monitoring (temperature, umidità, dust collection + over-limit alarm)

Small energy monitoring (meter data reading, power consumption statistics)

Remote I/O control: distributed small equipment networking (per esempio., multiple small pumps)

Implementation: Micro810 collects data → uploads to HMI / IoT platform for remote view and adjustment.

  1. Training & Educational Labs

Why suitable:

Low cost, easy to use, free software (Connected Components Workbench), ideal for vocational schools and in-house PLC training.

Typical uses:

PLC basic training (relay logic simulation, simple programming)

Employee automation training (equipment commissioning, Risoluzione dei problemi)

Industry 4.0 introduction: small networking, data acquisition exercises

  1. Small Control in Harsh Environments

Why suitable:

Wide temperature range, vibration-resistant, noise-resistant, stable without extra protection.

Typical uses:

Outdoor small equipment: pompe dell'acqua, streetlights, small PV positioning systems

Harsh industrial areas: dusty workshops, oily environments, vibrating machinery

High-altitude / low-temperature sites: no derating below 2000m, suitable for mines and field equipment

  1. Unsuitable Scenarios

The Micro810 is a compact micro PLC and not recommended for:

  1. High I/O count: Over 20 points → use Micro830/850
  2. Complex motion control: Multi-axis synchronization, precise servo positioning → use dedicated motion controllers
  3. High-availability redundant systems: centri dati, nuclear facilities → use high-end PLCs
  4. Large-scale networking: More than 10 units → use Micro850/870 or host systems

The core value of the Micro810 is “small but powerful, simple yet strong”.

It perfectly covers basic control needs within 12 I/O points, combining the low cost and simplicity of a smart relay with the logic flexibility and communication capability of a PLC.

It is the preferred micro PLC for small equipment automation, legacy machine retrofitting, and OEM volume applications.

Prec:

Lascia una risposta

Lasciate un messaggio