This is an abbreviation of elettrico terminology used in French-speaking environments. It actually refers to the Schneider Acti9 Vigi C120 series 500mA residual current protection accessory (RCD/earth leakage add-on module).

Qui:

Reglette means modular accessory / terminal strip.

120 indicates compatibility with the C120 series circuit breakers (frame size 125A).

=500 stands for the rated residual operating current of 500mA.

It is used to add earth leakage protection to high-current C120 circuit breakers, in compliance with IEC/EN 61009-2-1.

  1. Abbreviation vs. Official Model Number

“Reglette 120=500” is a common field abbreviation, corresponding to the following official Schneider full models by number of poles:

PoliCodice ordineModello completoTipo di protezione
2PA9N18567Vigi C120 2P 500mA AC typeElettromagnetico, istantaneo
3PA9N18568Vigi C120 3P 500mA AC typeElettromagnetico, istantaneo
4PA9N18571Vigi C120 4P 500mA AC typeElettromagnetico, istantaneo
4PA9N18599Vigi C120 4P 500mA A‑SI typeElettromagnetico, interference‑resistant
  1. Ripartizione del modello (using A9N18571 as example)
Segmento modelloSensoKey Description
A9Platform codeActi9 series low‑voltage distribution platform, for C120 breakers
NTipo di prodottoCircuit breaker accessory (leakage module)
18571Codice funzione18 = Vigi C120 series, 5 = 500mA sensitivity, 71 = 4P AC type
Vigi C120Nome della serieEarth leakage add‑on exclusively for C120 breakers, up to 125A
500mATripping currentTrips the breaker when leakage reaches 500mA
Tipo CAClasse di protezioneFor pure AC earth leakage; electromagnetic trip, no auxiliary power needed
  1. Specifiche tecniche principali (Official Standard)
ArticoloSpecificaApplicazione
Tipo di prodottoModular RCD accessory (DIN‑rail mount)Mounted to the right of C120 breaker, shared mechanism
Compatible breakersActi9 C120H / C120L (80/100/125UN)Only for C120 series; not compatible with IC65 etc.
Corrente operativa nominale≤ 125AMatches breaker rating, max 125A load
Rated residual current500mA (fisso)For indirect contact protection; attrezzature industriali, motori
Tipo di viaggioElettromagnetico (ELM)Voltage‑independent, works even during power loss
Classe di protezioneTipo CA / A‑SI typeA‑SI = electromagnetic interference‑resistant for harsh industry
Tensione nominale230/400V eFor 3‑phase 4‑wire / single‑phase industrial systems
Insulation voltage500V eMeets LV distribution insulation requirements
Montaggio35Guida DIN da mm, modular clipMechanically interlocked with C120 breaker
IndicatoreRed mechanical fault indicatorVisible trip indication without tools
  1. Elenco completo delle serie (Vigi C120)

By rated residual operating current:

Tripping Current2P Code3P Code4P CodeCaratteristiche
30mAA9N18563A9N18564A9N18565Protezione personale, istantaneo
300mAA9N18569A9N18570A9N18572Equipment protection, istantaneo / time‑delay
500mAA9N18567A9N18568A9N18571Heavy industrial protection, istantaneo (questo modello)
500mA‑SIA9N18599Interference‑resistant, for VFDs, motori
  1. Applicazioni tipiche

The 500mA Vigi C120 module is designed for heavy industrial use to avoid nuisance tripping from normal leakage during motor starting or VFD operation:

ApplicazioneMotivoRaccomandazione
Large motor circuitsNormal leakage on start-up; 500mA avoids nuisance trips while protecting insulationUse with C120H 3P 100A for motors above 75kW
VFD drive systemsHarmonic leakage on VFD output; 500mA suits industrial conditionsUse A‑SI type (A9N18599) for better immunity
Industrial switchboard busbar3‑phase 4‑wire distribution; prevents fire from insulation agingUse with C120L 4P 125A as incomer protection
Construction temporary power500mA provides equipment protection in harsh environments2P for single‑phase welders; 3P for mixers
Capacitor banksTransient leakage during switching; 500mA reduces frequent trippingUse with C120H 3P 80A
  1. Selezione & Installation Guidelines

6.1 Selection Principles

FattoreRaccomandazioneRischio
Sensibilità30mA for personnel; 300/500mA for equipment500mA in personnel zones creates shock risk
Poli2P for single‑phase; 3P for 3‑phase 3‑wire; 4P for 3‑phase 4‑wire3P in 3‑phase 4‑wire leaves neutral unprotected
Interference immunityA‑SI type (A9N18599) for VFD/motor systemsStandard AC type may mis‑trip or fail in EMI environments
Breaker matchOnly C120H/C120L (80–125A)Not compatible with IC65 / NSX

6.2 Installazione & Safety Rules

  1. Interblocco meccanico: Must be interlocked with a C120 breaker; do not use standalone or with other series.
  2. Test: Press the test button (T) monthly to verify correct operation.
  3. Cablaggio: Follow official diagrams strictly for phase and neutral connections.
  4. Ambiente: Indoor enclosure (IP20); outdoor use requires a protective box.
  5. Recommended Replacements

7.1 Schneider Upgraded Model

OriginaleUpgraded ModelImprovement
A9N18571 (4P 500mA AC)A9N18599 (4P 500mA A‑SI)Higher electromagnetic immunity for automation

7.2 Equivalenti del marchio internazionale

MarcaSerieModello sostitutivoKey Matching Specs
Siemens5SM5SM3 344‑04P, 500mA, Tipo CA, for 5SY6 125A
ABBDSDS203 M C125 A5003P, 500mA, Tipo CA, for S200 125A
EatonNZMNZM1‑XR5003P, 500mA, Tipo CA, for NZM1 125A

“Reglette 120=500” is the French abbreviation for Schneider’s Vigi C120 series 500mA earth leakage accessory, used to add industrial‑grade residual current protection to high‑current C120 circuit breakers.

Official recommended models:

A9N18567 (2P)

A9N18568 (3P)

A9N18571 (4P)

A9N18599 (4P, interference‑resistant)

Select based on pole number, immunity needs, and matching breaker. Always test after installation to ensure safe and stable operation of the industrial distribution system.