1SDA064868R1 is the official order code for the ABB Tmax XT Series Molded Case Circuit Breaker (MCCB), corresponding to the full model: XT4H 250 Ekip LS/I 4p F F Key Parameters Item Specification Series Tmax XT4 Series Rated Current In = 250A Poles 4-Pole Breaking Capacity H type: 50kA at 415V Release Unit Ekip LS/I ...

  • Dettagli del prodotto

1SDA064868R1 is the official order code for the ABB Tmax XT Series Molded Case Circuit Breaker (MCCB), corresponding to the full model:

XT4H 250 Ekip LS/I 4p F F

  1. Parametri chiave
ArticoloSpecifica
SerieTmax XT4 Series
Corrente nominaleIn = 250A
Poli4-Pole
Capacità di interruzioneH type: 50kA at 415V
Release UnitEkip LS/I electronic release
Funzioni di protezionel (sovraccarico) + S (short delay) + IO (instant)
MontaggioFisso / Collegamento frontale
Tensione nominale400/415V e
  1. Posizionamento del prodotto

Industrial-grade power distribution protection for power distribution panels, motor circuits, industrial equipment, and building power distribution

Mid-to-high end ABB MCCB with high reliability, suitable for automated power distribution systems

  1. Standard English Description (for tender / inquiry)

ABB Circuit Breaker MCCB Tmax XT4H250, 250UN, 4P, 50IL, Ekip LS/I, Fisso, 1SDA064868R1

  1. Common Alternative / Similar Models in the Same Series (XT4 250A 4P)

1SDA064867R1: XT4H250 3P

1SDA064898R1: XT4L250 4P (lower breaking 36kA)

1SDA064878R1: XT4S250 4P (medium breaking 42kA)

Complete Model List, Brand Cross‑Reference & Order Code Manual

for ABB Tmax XT Series MCCBs

  1. Core Model System

1.1 Frame Specifications & Parametri di base

The Tmax XT series covers frame currents from 160A to 1600A across 7 frame sizes, suitable for various power‑rating distribution protections:

FrameCorrente del fotogrammaBreaking ClassPoliTensione nominaleApplication
XT1160UNS/L/N/H3P/4P690V AC/500V DCSmall distribution, lighting circuits
XT2160UNS/L/N/H/V3P/4P690V AC/500V DCIndustrial equipment, motor protection
XT3250UNS/L/N/H3P/4P690V AC/500V DCBuilding distribution, small‑medium factories
XT4250UNS/L/N/H/V3P/4P690V AC/500V DCLarge motors, industrial automation
XT5630UNL/N/H3P/4P690V AC/500V DCDistribution rooms, large factories
XT61000UNL/N/H3P/4P690V AC/500V DCLarge power stations, heavy industry
XT7/XT7M1250A/1600AL/N/H/M3P/4P690V AC/500V DCExtra‑large industry, power grid support

1.2 Model Coding Rule

XT[Frame][Breaking Class][Corrente del fotogramma] [Release Type] [Corrente nominale] [Poli] [Montaggio]

Esempio: XT4H 250 Ekip LS/I 4p F F (Order code: 1SDA064868R1)

1.3 Breaking Capacity Classes

ClassCapacità di interruzione (415V)Application
S36ILAmbiente industriale standard
l42ILGeneral industrial loads
N50ILHeavy industry, large motors
H85ILHigh short‑circuit risk areas
V120kA/150kAExtra‑large factories, grid side
M200ILExtra‑high voltage distribution, special industry
  1. Complete Model List by Frame

XT1 160A Series (Basic Type)

Modello completoOrder CodeReleaseCorrente nominaleCaratteristiche
XT1S 160 TMF 16-160 3P FF1SDA074621R1Thermal‑Magnetic Fixed16-160UNEconomic, 36IL
XT1L 160 TMD 16-160 4P FF1SDA074658R1Thermal‑Magnetic Adjustable16-160UNAdjustable overload, 42IL
XT1N 160 Ekip LS 100 3P FF1SDA074725R1Electronic LS100UNElectronic protection, 50IL

XT2 160A Series (High Performance)

Modello completoOrder CodeReleaseCorrente nominaleCaratteristiche
XT2L 160 TMD 32-320 4P FF1SDA067662R1Thermal‑Magnetic Adjustable32-320UN120IL, motor protection
XT2V 160 Ekip LSIG 160 3P FF1SDA067721R1Electronic LSIG160UN150IL, protezione completa
XT2N 160 Ekip C LSIG R63 FF 3P10152869Electronic LSIG + Comms63UNWith communication, smart distribution

XT3 250A Series

Modello completoOrder CodeReleaseCorrente nominaleCaratteristiche
XT3L 250 TMD 32-250 3P FF1SDA064821R1Thermal‑Magnetic Adjustable32-250UN42IL, building distribution
XT3N 250 Ekip LS 200 4P FF1SDA064845R1Electronic LS200UN50IL, industrial automation
XT3H 250 Ekip LSIG 250 3P FF1SDA064872R1Electronic LSIG250UN85IL, heavy‑duty protection

XT4 250A Series (Key Reference)

Modello completoOrder CodeReleaseCorrente nominaleCaratteristiche
XT4H 250 Ekip LS/I 4p FF1SDA064868R1Electronic LS/I250UN50IL
XT4L 250 TMD 32-250 3P FF1SDA064867R1Thermal‑Magnetic Adjustable32-250UN42IL, 3P
XT4V 250 Ekip LSIG 250 4P FF1SDA064898R1Electronic LSIG250UN120IL

XT5‑XT7 Series (High Power)

FrameModello completoOrder CodeCorrente nominaleCapacità di interruzioneApplication
XT5XT5N 630 Ekip LSIG 630 3P FF1SDA100491R1630UN50ILDistribution room, large factory
XT6XT6H 1000 Ekip LSIG 1000 4P FF1SDA100628R11000UN85ILHeavy industry, power station
XT7XT7M 1250 Ekip LSIG 1250 3P FF1SDA100755R11250UN100ILExtra‑large industry
  1. Release Unit Types & Functions
ReleaseEnglishProtezioneApplicationAccuracy
TMFThermal-Magnetic Fixedl + IOLighting, small motors±15%
TMDThermal-Magnetic Adjustablel (adj) + IO (adj)Industrial equipment, pumps±10%
Ekip LSElectronic LSl + SDistribution, trasformatori±5%
Ekip LS/IElectronic LS/Il + S + IOMotor circuits, industrial loads±5%
Ekip LSIGElectronic LSIGl + S + IO + G (ground)Sensitive loads, centri dati±3%
Ekip TouchDigital TouchFull + ComunicazioneSmart distribution±2%
  1. Main Brand Cross‑Reference

4.1 XT1/XT2 (160UN)

ABBSchneider (NSX)Siemens (3VA)Eaton (IZM)Cinto (NXM)Breaking
XT2N 160 Ekip LS 100 3PNSX160N Micrologic 5.2E 100A3VA2160-5EF32-0AA0IZM91H160 TM-D 100ANXM160S 100A50IL
XT2V 160 Ekip LSIG 160 4PNSX160H Micrologic 6.3E 160A3VA2160-5FF32-0AA0IZM91V160 LSIG 160ANXM160H 160A120IL

4.2 XT3/XT4 (250UN)

ABBSchneider (NSX)Siemens (3VA)Eaton (IZM)Cinto (NXM)Order Code
XT4H 250 Ekip LS/I 4PNSX250N Micrologic 5.3E 250A3VA3250-5EF32-0AA0IZM92H250 LS/I 250ANXM250H 250A1SDA064868R1
XT4L 250 TMD 250 3PNSX250S Micrologic 2.3 250UN3VA3250-5DF32-0AA0IZM92L250 TM-D 250ANXM250S 250A1SDA064867R1

4.3 XT5‑XT7 (630A~1600A)

ABBSchneider (MTZ)Siemens (3VA)Eaton (IZM)Breaking
XT5N 630 Ekip LSIG 630 3PMTZ630N Micrologic 5.3E 630A3VA5630-5EF32-0AA0IZM93N630 LSIG 630A50IL
XT7M 1250 Ekip LSIG 1250 3PMTZ1250H Micrologic 6.3E 1250A3VA61250-5FF32-0AA0IZM96M1250 LSIG 1250A100IL
  1. Order Code Rules & Examples

5.1 Standard Format

1SDA[6 digits]R1 (R1 = standard version)

5.2 Common Order Codes

ApplicationABB Full ModelOrder Code
Controllo motorioXT4H 250 Ekip LS/I 4P FF1SDA064868R1
DistributionXT2N 160 Ekip LS 100 3P FF1SDA074725R1
BuildingXT3L 250 TMD 200 3P FF1SDA064821R1
Data CenterXT2V 160 Ekip LSIG 160 4P FF1SDA067721R1
  1. Selection & Replacement Guide

6.1 Core Selection Principles

  1. Current matching: In ≥ 1.2 × load current; frame current ≥ 1.5 × In
  2. Potere di interruzione: Icu ≥ expected short‑circuit current (≥50kA recommended for industry)
  3. Protezione: LS/I for motors; LS for distribution; LSIG for sensitive loads
  4. Montaggio: F = Fixed, D = Plug‑in, W = Drawout (FF = Fixed Front)

6.2 Replacement Steps

  1. Confirm frame + breaking class + release + poli
  2. Match equivalent frame from target brand
  3. Maintain breaking capacity ≥ original
  4. Verify mounting dimensions and connections